A novel composite targeting method using high-field magnetic resonance imaging for subthalamic nucleus deep brain stimulation Clinical article

被引:31
|
作者
Toda, Hiroki [1 ,6 ]
Sawamoto, Nobukatsu [5 ]
Hanakawa, Takashi [4 ,5 ]
Saiki, Hidemoto [2 ]
Matsumoto, Sadayuki [2 ]
Okumura, Ryosuke [3 ]
Ishikawa, Masatsune [1 ]
Fukuyama, Hidenao [5 ]
Hashimoto, Nobuo [6 ]
机构
[1] Tazuke Kofukai Med Res Inst, Dept Neurosurg, Osaka 5308480, Japan
[2] Tazuke Kofukai Med Res Inst, Dept Neurol, Osaka 5308480, Japan
[3] Tazuke Kofukai Med Res Inst, Dept Radiol, Osaka 5308480, Japan
[4] Japan Sci & Technol Agcy, PRESTO, Saitama, Japan
[5] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Kyoto, Japan
[6] Kyoto Univ, Grad Sch Med, Dept Neurosurg, Kyoto, Japan
关键词
deep brain stimulation; Parkinson disease; postmammillary commissure; subthalamic nucleus; 3-T MR imaging; PARKINSONS-DISEASE; ELECTROPHYSIOLOGICAL GUIDANCE; TECHNICAL APPROACH; BASAL GANGLIA; LOCALIZATION; ACCURACY; SURGERY; MRI; COMMISSURE; DISORDERS;
D O I
10.3171/2008.12.JNS0861
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Accurate localization of the subthalamic nucleus (STN) is important for proper placement of the electrodes in deep brain stimulation (DBS) surgery for patients with advanced Parkinson disease. The authors evaluated the accuracy of our modified composite targeting method and the value of using high-field MR imaging for targeting the STN. Methods. Thirteen patients with advanced Parkinson disease underwent bilateral STN DBS based on 3-T MR imaging, and 13 patients underwent surgery based on 1.5-T MR imaging. By sequentially referring to the postmammillary commissure, the red nucleus, the mammillothalamic tract, and the STN, the modified composite targeting method determined the stereotactic coordinates for targeting the STN. The accuracy and efficacy of the composite targeting method and 3-T MR imaging were evaluated by using the intraoperative microelectrode recording, the postoperative imaging study, and the postoperative clinical improvement. Results. The landmark structures for targeting the STN were visualized clearly with 3-T MR imaging. The mean (+/- SD) path length through the STN of the central track was 4.9 +/- 1.1 mm in the 3-T group and 3.1 +/- 2.0 mm in the 1.5-T group (p < 0.001). Twenty-one (81%) of 26 electrodes were placed in the central track in the 3-T group, whereas 8 (31%) of 26 electrodes were placed in the central track in the 1.5-T group (p = 0.006). The rest of the electrodes were placed in the noncentral optimum track for alleviating parkinsonian motor symptoms. The mean Unified Parkinson's Disease Rating Scale motor part score during off period was reduced by 53% in the 3-T group and by 41% in the 1.5-T group (p = 0.14). The mean reductions of levodopa equivalent daily doses were 48.6% in the 3-T group and 43.7% in the 1.5-T group (p = 0.61). Conclusions. The use of the modified composite targeting method referring to the multiple landmarks with 3-T MR imaging offers reliable and clinically effective target for STN DBS surgery. (DOI: 10.3171/2008.12.JNS0861)
引用
收藏
页码:737 / 745
页数:9
相关论文
共 50 条
  • [1] Composite targeting method using high-field magnetic resonance imaging for subthalamic nucleus deep brain stimulation
    Toda, H.
    Sawamoto, N.
    Hanakawa, T.
    Saiki, H.
    Matsumoto, S.
    Ishikawa, M.
    Fukuyama, H.
    Hashimoto, N.
    MOVEMENT DISORDERS, 2008, 23 (01) : S116 - S116
  • [2] Magnetic resonance imaging of the subthalamic nucleus for deep brain stimulation
    Chandran, Arjun S.
    Bynevelt, Michael
    Lind, Christopher R. P.
    JOURNAL OF NEUROSURGERY, 2016, 124 (01) : 96 - 105
  • [3] Variability in subthalamic nucleus targeting for deep brain stimulation with 3 and 7 Tesla magnetic resonance imaging
    Isaacs, Bethany R.
    Heijmans, Margot
    Kuijf, Mark L.
    Kubben, Pieter L.
    Ackermans, Linda
    Temel, Yasin
    Keuken, Max C.
    Forstmann, Birte U.
    NEUROIMAGE-CLINICAL, 2021, 32
  • [4] Subthalamic nucleus deep brain stimulation for Parkinson's disease: Magnetic resonance imaging targeting using visible anatomical landmarks
    Pollo, C
    Meuli, R
    Maeder, P
    Vingerhoets, F
    Ghika, J
    Villemure, JG
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2003, 80 (1-4) : 76 - 81
  • [5] Comparison of magnetic resonance imaging sequences for depicting the subthalamic nucleus for deep brain stimulation
    Nagahama H.
    Suzuki K.
    Shonai T.
    Aratani K.
    Sakurai Y.
    Nakamura M.
    Sakata M.
    Radiological Physics and Technology, 2015, 8 (1) : 30 - 35
  • [6] The Role of 3T Magnetic Resonance Imaging for Targeting the Human Subthalamic Nucleus in Deep Brain Stimulation for Parkinson Disease
    Longhi, Michele
    Ricciardi, Giuseppe
    Tommasi, Giorgio
    Nicolato, Antonio
    Foroni, Roberto
    Bertolasi, Laura
    Beltramello, Alberto
    Moretto, Giuseppe
    Tinazzi, Michele
    Gerosa, Massimo
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2015, 76 (03) : 181 - 189
  • [7] CLINICAL SUBTHALAMIC NUCLEUS PREDICTION FROM HIGH-FIELD BRAIN MRI
    Kim, Jinyoung
    Duchin, Yuval
    Sapiro, Guillermo
    Vitek, Jerrold
    Harel, Noam
    2015 IEEE 12TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2015, : 1264 - 1267
  • [8] Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy
    Starr, Philip A.
    Martin, Alastair J.
    Ostrem, Jill L.
    Talke, Pekka
    Levesque, Nadja
    Larson, Paul S.
    JOURNAL OF NEUROSURGERY, 2010, 112 (03) : 479 - 490
  • [9] A Computerized Microelectrode Recording to Magnetic Resonance Imaging Mapping System for Subthalamic Nucleus Deep Brain Stimulation Surgery
    Dodani, Sunjay S.
    Lu, Charles W.
    Aldridge, J. Wayne
    Chou, Kelvin L.
    Patil, Parag G.
    OPERATIVE NEUROSURGERY, 2018, 14 (06) : 661 - 667
  • [10] Brain biopsy using high-field strength interventional magnetic resonance imaging
    Hall, WA
    Martin, AJ
    Liu, HY
    Nussbaum, ES
    Maxwell, RE
    Truwit, CL
    NEUROSURGERY, 1999, 44 (04) : 807 - 813