Research on Spectroradiometer for Irradiance Calibration in Ageing Tests

被引:0
|
作者
Lin, Fangsheng [1 ]
Yin, Dejin [1 ]
Li, Tiecheng [1 ]
Ji, Muyao [1 ]
机构
[1] Shanghai Inst Measurement & Testing Technol, Shanghai 201203, Peoples R China
关键词
spectroradiometer; irradiance calibration; ageing test; xenon arc lamp;
D O I
10.1117/12.2541496
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Instead of natural exposing tests in atmosphere environment, we use artificial accelerated weathering apparatus to simulate solar radiation in ageing tests. Xenon arc lamps are most widely used to simulate spectral distribution of the sun in chambers. According to JJF1525-2015 Calibration Specification for Irradiance of Artificial Accelerated Weathering Apparatus of Xenon Arc Lamp, there are three methods to detect the irradiance: radiometer method, spectroradiometer method and standard lamp method. In this paper, we compare three methods and focus on the spectroradiometer method. Because different wavelength ranges need different radiometers, the best method to calibrate the irradiance in ageing tests is spectroradiometer method. By experiments, we verify the irradiance correspondence between 300nm similar to 400nm and 340nm or 420nm to test the accuracy of spectroradiometer. We also study the factors affecting the irradiance calibration by spectroradiometer. At last we conclude that spectroradiometer is more suitable for irradiance calibration in different ageing tests and provide guidance for daily calibration.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Multiangle imaging spectroradiometer: optical characterization of the calibration panels
    McGuckin, Brendan T.
    Haner, David A.
    Menzies, Robert T.
    Applied Optics, 1997, 36 (27): : 7016 - 7022
  • [32] Radiometric Calibration of Circular Variable Filter Type Spectroradiometer
    Xiang Kunzhu
    Shi Hailiang
    Sun Xiongwei
    Zhu Feng
    Wang Xianhua
    Ye Hanhan
    ACTA OPTICA SINICA, 2023, 43 (23)
  • [33] Calibration of the Odyssey™ Photosynthetic Irradiance Recorder™ for absolute irradiance measures
    Shaffer, Jared M.
    Beaulieu, Jake J.
    JOURNAL OF FRESHWATER ECOLOGY, 2012, 27 (04) : 599 - 605
  • [34] Multiangle imaging spectroradiometer: Optical characterization of the calibration panels
    McGuckin, BT
    Haner, DA
    Menzies, RT
    APPLIED OPTICS, 1997, 36 (27): : 7016 - 7022
  • [35] On the use of ASTM closed vessel tests in accelerated ageing research
    Sawoszczuk, Tornasz
    Baranski, Andrzej
    Lagan, Janusz Marek
    Lojewski, Tornasz
    Zieba, Katarzyna
    JOURNAL OF CULTURAL HERITAGE, 2008, 9 (04) : 401 - 411
  • [36] Direct Spectral Irradiance Measurements from Rotating Shadowband EKO Grating Spectroradiometer
    Po, Mario
    Hoogendijk, Kees
    Beuttell, Will
    Kazunori, Shibayama
    Takeuchi, Eiji
    2018 IEEE 7TH WORLD CONFERENCE ON PHOTOVOLTAIC ENERGY CONVERSION (WCPEC) (A JOINT CONFERENCE OF 45TH IEEE PVSC, 28TH PVSEC & 34TH EU PVSEC), 2018, : 2337 - 2340
  • [37] Opto-Mechanical Design of Unattended Irradiance Spectroradiometer in Reflective Solar Bands
    Zhang Quan
    Li Xin
    Zhang Yanna
    Zhai Wenchao
    Liu Enchao
    Zheng Xiaobing
    ACTA OPTICA SINICA, 2019, 39 (03)
  • [38] CALIBRATION PLANS FOR THE MULTI-ANGLE IMAGING SPECTRORADIOMETER (MISR)
    BRUEGGE, CJ
    DUVAL, VG
    CHRIEN, NL
    DINER, DJ
    METROLOGIA, 1993, 30 (04) : 213 - 221
  • [39] Research on the irradiance calibration of a VUV dual-grating spectrometer based on synchrotron radiation
    Li, Hanshuang
    Li, Bo
    Wang, Shurong
    Li, Zhanfeng
    Qi, Jin
    Yu, Miao
    Huang, Yu
    Li, Yue
    Barbutis, Annett
    Lubeck, Janin
    Klein, Roman
    Kroth, Simone
    Paustian, Wolfgang
    Ressin, Maja
    Thornagel, Reiner
    OPTICS COMMUNICATIONS, 2020, 475
  • [40] Characterization and performance of optical input systems for a calibration transfer spectroradiometer
    Marketon, J
    Cooper, JW
    Smith, GR
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES VIII, 2004, 5570 : 482 - 491