Research on Spectroradiometer for Irradiance Calibration in Ageing Tests

被引:0
|
作者
Lin, Fangsheng [1 ]
Yin, Dejin [1 ]
Li, Tiecheng [1 ]
Ji, Muyao [1 ]
机构
[1] Shanghai Inst Measurement & Testing Technol, Shanghai 201203, Peoples R China
关键词
spectroradiometer; irradiance calibration; ageing test; xenon arc lamp;
D O I
10.1117/12.2541496
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Instead of natural exposing tests in atmosphere environment, we use artificial accelerated weathering apparatus to simulate solar radiation in ageing tests. Xenon arc lamps are most widely used to simulate spectral distribution of the sun in chambers. According to JJF1525-2015 Calibration Specification for Irradiance of Artificial Accelerated Weathering Apparatus of Xenon Arc Lamp, there are three methods to detect the irradiance: radiometer method, spectroradiometer method and standard lamp method. In this paper, we compare three methods and focus on the spectroradiometer method. Because different wavelength ranges need different radiometers, the best method to calibrate the irradiance in ageing tests is spectroradiometer method. By experiments, we verify the irradiance correspondence between 300nm similar to 400nm and 340nm or 420nm to test the accuracy of spectroradiometer. We also study the factors affecting the irradiance calibration by spectroradiometer. At last we conclude that spectroradiometer is more suitable for irradiance calibration in different ageing tests and provide guidance for daily calibration.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Research on Irradiance Calibration in Aging Tests
    Lin, Fangsheng
    Li, Tiecheng
    Ji, Muyao
    SEVENTH SYMPOSIUM ON NOVEL PHOTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATIONS, 2021, 11763
  • [2] Calibration method of spectroradiometer based on direct solar irradiance
    Tang, Xiaoxiao
    Li, Jianyu
    Sun, Fengying
    Dai, Congming
    Wei, Heli
    JOURNAL OF OPTICS-INDIA, 2024, 53 (03): : 1872 - 1881
  • [3] Calibration method of spectroradiometer based on direct solar irradiance
    Tang, Xiaoxiao
    Li, Jianyu
    Sun, Fengying
    Dai, Congming
    Wei, Heli
    JOURNAL OF OPTICS-INDIA, 2024, 53 (03): : 1872 - 1881
  • [4] Spectral irradiance calibration research of the solar backscattered ultraviolet spectroradiometer in air/vacuum conditions
    Yang, Xiaohu
    Wang, Shurong
    Huang, Yu
    Guangxue Xuebao/Acta Optica Sinica, 2012, 32 (01): : 010100 - 1
  • [5] Calibration method of solar irradiance spectroradiometer based on tunable laser
    Zhang, Yanna, 1600, Chinese Society of Astronautics (43):
  • [6] The Research on Calibration Technology of Vacuum Ultraviolet Spectroradiometer
    Sun Guang-wei
    Sun Hong-sheng
    Wang Jia-peng
    Wu Ke-xuan
    Zhang Yu-guo
    SPACE OPTICS, TELESCOPES, AND INSTRUMENTATION (AOPC 2019), 2019, 11341
  • [7] UV-VUV Spectral irradiance responsivity calibration for space remote sensing spectroradiometer
    Huang, Yu
    Wang, Shurong
    Lin, Guanyu
    Wang, Longqi
    ADVANCED MATERIALS AND DEVICES FOR SENSING AND IMAGING III, 2008, 6829
  • [8] CALIBRATION OF A FIELD SPECTRORADIOMETER
    LEAMER, RW
    LAROCCA, AJ
    OPTICAL ENGINEERING, 1973, 12 (04) : 124 - 130
  • [9] Characteristics in the calibration of the fiber spectroradiometer
    Wu Zhifeng
    Dai Caihong
    Wang Yanfei
    Chen Binhua
    Li Xiangzhao
    2013 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC DEVICES AND OPTICAL SIGNAL PROCESSING, 2013, 9043
  • [10] Diffraction effect in the calibration of the spectroradiometer
    Wu Zhi-feng
    Dai Cai-hong
    Yu Jia-Lin
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: IMAGING SENSORS AND APPLICATIONS, 2013, 8908