Use of Balloon Aortic Valvuloplasty to Size the Aortic Annulus Before Implantation of a Balloon-Expandable Transcatheter Heart Valve

被引:47
|
作者
Babaliaros, Vasilis C. [1 ]
Junagadhwalla, Zahid [1 ]
Lerakis, Stamatios [1 ]
Thourani, Vinod [1 ]
Liff, David [1 ]
Chen, Edward [1 ]
Vassiliades, Thomas [1 ]
Chappell, Clay [1 ]
Gross, Nathan [1 ]
Patel, Ateet [1 ]
Howell, Sharon [1 ]
Green, Jacob T. [1 ]
Veledar, Emir [1 ]
Guyton, Robert [1 ]
Block, Peter C. [1 ]
机构
[1] Emory Univ Hosp, Dept Cardiol, Andreas Gruentzig Cardiovasc Ctr, Atlanta, GA 30322 USA
关键词
percutaneous; transcatheter; aortic; valve; annulus; aortic stenosis; balloon aortic valvuloplasty; PROSTHESIS; STENOSIS; REPLACEMENT;
D O I
10.1016/j.jcin.2009.09.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Our aim was to describe the use of balloon aortic valvuloplasty (BAV) to select proper transcatheter heart valve (THV) size. Background Transesophageal echocardiogram (TEE) measurement alone of the aortic annulus may not be adequate to select a THV size. BAV can more accurately size the aortic annulus. We report our experience using this strategy in patients undergoing THV implantation. Methods Twenty-seven patients underwent sizing of the aortic annulus by BAV and TEE. We implanted the minimal THV size that was greater than the annulus measured by BAV. Results The annulus measured by TEE was 21.3 +/- 1.6 mm and by BAV was 22.6 +/- 1.8 mm (p < 0.001). The number of balloon inflations was 2.7 +/- 0.7 (range 2 to 4), and the balloon sizes used were 22.0 +/- 1.8 mm (range 20 to 25 mm). Fourteen patients (52%) required upsizing of the initial balloon suggested by TEE; rapid pacing duration was 8 +/- 1.3 s (range 6 to 11 s). No change in aortic insufficiency or hemodynamic instability occurred with BAV. Fifteen patients (56%) received a 23-mm THV; 12 patients a 26-mm THV. No coronary occlusion, annular damage, or THV embolization occurred. Paravalvular leak was grade <= 1 in all patients. In 7 patients (26%), balloon sizing resulted in selection of a specific THV size that could not be done by TEE alone. Conclusions BAV sizing of the aortic annulus is safe and is an important adjunct to TEE when selecting THV size. Implanting the minimal THV greater than the BAV annulus size resulted in no adverse events. These data suggest that use of BAV for THV selection may improve the safety and efficacy of THV implantation. (J Am Coll Cardiol Intv 2010;3:114-8) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:114 / 118
页数:5
相关论文
共 50 条
  • [21] Transcatheter aortic valve implantation with balloon-expandable valve: early experience from China
    Lu, Qingsheng
    Pei, Yifei
    Wu, Hong
    Wang, Zhinong
    Jing Zaiping
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2015, 30 (04): : 425 - 432
  • [22] Repositionable Versus Balloon-Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis
    Pilgrim, Thomas
    Stortecky, Stefan
    Nietlispach, Fabian
    Heg, Dik
    Tueller, David
    Toggweiler, Stefan
    Ferrari, Enrico
    Noble, Stephane
    Maisano, Francesco
    Jeger, Raban
    Roffi, Marco
    Gruenenfelder, Juerg
    Huber, Christoph
    Wenaweser, Peter
    Windecker, Stephan
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (11):
  • [23] Utility of balloon aortic valvuloplasty in the transcatheter aortic valve implantation era
    Dawson, Luke
    Huang, Alex
    Selkrig, Laura
    Shaw, James A.
    Stub, Dion
    Walton, Antony
    Duffy, Stephen J.
    OPEN HEART, 2020, 7 (01):
  • [24] The role of balloon aortic valvuloplasty in the era of transcatheter aortic valve implantation
    Waclawski, Jacek
    Wilczek, Krzysztof
    Pres, Damian
    Krajewski, Adam
    Polonski, Lech
    Zembala, Marian
    Gasior, Mariusz
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA-POLISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 12 (01) : 8 - 13
  • [25] Transcatheter Aortic Valve Replacement With the SAPIEN 3 A New Balloon-Expandable Transcatheter Heart Valve
    Binder, Ronald K.
    Rodes-Cabau, Josep
    Wood, David A.
    Mok, Michael
    Leipsic, Jonathon
    De Larochelliere, Robert
    Toggweiler, Stefan
    Dumont, Eric
    Freeman, Melanie
    Willson, Alexander B.
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) : 293 - 300
  • [26] Impact of Balloon-Expandable Transcatheter Aortic Valve Size on Stent and Leaflet Stresses
    Krishnan, Kapil
    Dvir, Danny
    Ye, Jian
    Ge, Liang
    Tseng, Elaine
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B270 - B270
  • [27] Balloon-expandable transapical transcatheter aortic valve implantation with or without predilation of the aortic valve: results of a multicentre registry
    Strauch, Justus
    Wendt, Daniel
    Diegeler, Anno
    Heimeshoff, Martin
    Hofmann, Steffen
    Holzhey, David
    Oertel, Frank
    Wahlers, Thorsten
    Kurucova, Jana
    Thoenes, Martin
    Deutsch, Cornelia
    Bramlage, Peter
    Schroefel, Holger
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (04) : 771 - 777
  • [28] Overexpansion of Balloon-Expandable Aortic Transcatheter Heart Valves in the Mitral Valve Position
    Al-Hijji, Mohammed
    Eleid, Mackram
    Wang, Dee Dee
    Kodali, Susheel
    Kaptzan, Tatiana
    El Sabbagh, Abdallah
    Oh, Jae
    O'Neill, William
    Rihal, Chet
    Guerrero, Mayra
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B149 - B150
  • [29] Optimizing Valve Sizing in Balloon-Expandable Transcatheter Aortic Valve Replacement
    Krishnaswamy, Amar
    Kapadia, Samir R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (17) : 1706 - 1709
  • [30] Prevention and Management of Transcatheter Balloon-Expandable Aortic Valve Malposition
    Al Ali, Abdullah M.
    Altwegg, Lukas
    Horlick, Eric M.
    Feindel, Christopher
    Thompson, Christopher R.
    Cheung, Anson
    Carere, Ronald G.
    Humphries, Karin
    Ye, Jian
    Masson, Jean-Bernard
    Webb, John G.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) : 573 - 578