Use of Balloon Aortic Valvuloplasty to Size the Aortic Annulus Before Implantation of a Balloon-Expandable Transcatheter Heart Valve

被引:47
|
作者
Babaliaros, Vasilis C. [1 ]
Junagadhwalla, Zahid [1 ]
Lerakis, Stamatios [1 ]
Thourani, Vinod [1 ]
Liff, David [1 ]
Chen, Edward [1 ]
Vassiliades, Thomas [1 ]
Chappell, Clay [1 ]
Gross, Nathan [1 ]
Patel, Ateet [1 ]
Howell, Sharon [1 ]
Green, Jacob T. [1 ]
Veledar, Emir [1 ]
Guyton, Robert [1 ]
Block, Peter C. [1 ]
机构
[1] Emory Univ Hosp, Dept Cardiol, Andreas Gruentzig Cardiovasc Ctr, Atlanta, GA 30322 USA
关键词
percutaneous; transcatheter; aortic; valve; annulus; aortic stenosis; balloon aortic valvuloplasty; PROSTHESIS; STENOSIS; REPLACEMENT;
D O I
10.1016/j.jcin.2009.09.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Our aim was to describe the use of balloon aortic valvuloplasty (BAV) to select proper transcatheter heart valve (THV) size. Background Transesophageal echocardiogram (TEE) measurement alone of the aortic annulus may not be adequate to select a THV size. BAV can more accurately size the aortic annulus. We report our experience using this strategy in patients undergoing THV implantation. Methods Twenty-seven patients underwent sizing of the aortic annulus by BAV and TEE. We implanted the minimal THV size that was greater than the annulus measured by BAV. Results The annulus measured by TEE was 21.3 +/- 1.6 mm and by BAV was 22.6 +/- 1.8 mm (p < 0.001). The number of balloon inflations was 2.7 +/- 0.7 (range 2 to 4), and the balloon sizes used were 22.0 +/- 1.8 mm (range 20 to 25 mm). Fourteen patients (52%) required upsizing of the initial balloon suggested by TEE; rapid pacing duration was 8 +/- 1.3 s (range 6 to 11 s). No change in aortic insufficiency or hemodynamic instability occurred with BAV. Fifteen patients (56%) received a 23-mm THV; 12 patients a 26-mm THV. No coronary occlusion, annular damage, or THV embolization occurred. Paravalvular leak was grade <= 1 in all patients. In 7 patients (26%), balloon sizing resulted in selection of a specific THV size that could not be done by TEE alone. Conclusions BAV sizing of the aortic annulus is safe and is an important adjunct to TEE when selecting THV size. Implanting the minimal THV greater than the BAV annulus size resulted in no adverse events. These data suggest that use of BAV for THV selection may improve the safety and efficacy of THV implantation. (J Am Coll Cardiol Intv 2010;3:114-8) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:114 / 118
页数:5
相关论文
共 50 条
  • [11] Balloon-expandable transaortic transcatheter aortic valve implantation with or without predilation
    Bonaros, Nikolaos
    Kofler, Markus
    Frank, Derk
    Cocchieri, Riccardo
    Jagielak, Dariusz
    Aiello, Marco
    Lapeze, Joel
    Laine, Mika
    Chocron, Sidney
    Muir, Douglas
    Eichinger, Walter
    Thielmann, Matthias
    Labrousse, Louis
    Bapat, Vinayak
    Rein, Kjell Arne
    Verhoye, Jean-Philippe
    Gerosa, Gino
    Baumbach, Hardy
    Deutsch, Cornelia
    Bramlage, Peter
    Thoenes, Martin
    Romano, Mauro
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (03): : 915 - 923
  • [12] Balloon Aortic Valvuloplasty in the Transcatheter Aortic Valve Implantation Era
    Arturo Samaja, Gustavo
    HEART INTERNATIONAL, 2023, 17 (01): : 13 - 18
  • [13] Deformation of a balloon-expandable transcatheter heart valve during transcatheter aortic valve replacement
    Yashima, Fumiaki
    Sato, Masatoshi
    Yoshijima, Nobuhiro
    Nara, Tsutomu
    Kasai, Mio
    Hashizume, Kenichi
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2024, : 199 - 200
  • [14] Contemporary Use of Balloon Aortic Valvuloplasty in the Era of Transcatheter Aortic Valve Implantation
    Hui, Dawn S.
    Shavelle, David M.
    Cunningham, Mark J.
    Matthews, Ray V.
    Starnes, Vaughn A.
    TEXAS HEART INSTITUTE JOURNAL, 2014, 41 (05): : 469 - 476
  • [15] Late migration of balloon-expandable transcatheter aortic valve
    Lauten, Alexander
    Hamadanchi, Ali
    Doenst, Torsten
    Figulla, Hans R.
    EUROPEAN HEART JOURNAL, 2013, 34 (32) : 2509 - 2509
  • [16] Balloon-Expandable Prostheses for Transcatheter Aortic Valve Replacement
    Ribeiro, Henrique Barbosa
    Urena, Marina
    Allende, Ricardo
    Amat-Santos, Ignacio J.
    Rodes-Cabau, Josep
    PROGRESS IN CARDIOVASCULAR DISEASES, 2014, 56 (06) : 583 - 595
  • [17] Comparison of Balloon-expandable and Self-expandable Bioprosthesis for Transcatheter Aortic Valve Implantation
    Napodano, Massimo
    Gasparetto, Valeria
    Fraccaro, Chiara
    Tarantini, Giuseppe
    Yzeiraj, Ermela
    Buja, Paolo
    Pittarello, Demetrio
    D'Onofrio, Augusto
    Gerosa, Gino
    Isabella, Giambattista
    Iliceto, Sabino
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B39 - B39
  • [18] Outcomes and treatment strategy of transcatheter aortic valve replacement with balloon-expandable valve in borderline-size annulus
    Isogai, Toshiaki
    Spilias, Nikolaos
    Bakhtadze, Beka
    Sabbak, Nabil
    Denby, Kara J.
    Layoun, Habib
    Agrawal, Ankit
    Shekhar, Shashank
    Yun, James J.
    Puri, Rishi
    Harb, Serge C.
    Reed, Grant W.
    Krishnaswamy, Amar
    Kapadia, Samir R.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 66 : 6 - 14
  • [19] Aortic root volume is associated with contained rupture of the aortic annulus in balloon-expandable transcatheter aortic valve replacement
    Reinoehl, Jochen
    Psyrakis, Dimitrios
    Kaier, Klaus
    Kodirov, Sodikdjon
    Siepe, Matthias
    Gutmann, Anja
    von zur Muehlen, Constantin
    Moser, Martin
    Ahrens, Ingo
    Pache, Gregor
    Zirlik, Andreas
    Langer, Mathias
    Beyersdorf, Friedhelm
    Zehender, Manfred
    Bode, Christoph
    Blanke, Philipp
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (04) : 807 - 817
  • [20] Balloon-Expandable or Self-Expandable Valves in Valve-in-Valve Transcatheter Aortic Valve Implantation?
    Van Nieuwkerk, Astrid
    Fernandez-Nofrerias, Eduard
    Tchetche, Didier
    Brito, Fabio, Jr.
    Barbanti, Marco
    Kornowski, Ran
    Latib, Azeem
    d'Onofrio, Augusto
    Ribichini, Flavio
    Tello, Vicente Mainar
    Dumonteil, Nicolas
    Baan, Jan
    Abizaid, Alexandre
    Sartori, Samantha
    d'Errigo, Paola
    Tarantini, Giuseppe
    Lunardi, Mattia
    Orvin, Katia
    Pagnesi, Matteo
    Ghattas, Angie
    Dangas, George
    Mehran, Roxana
    Delewi, Ronak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B66 - B66