3D pull-out finite element simulation of the pedicle screw-trabecular bone interface at strain rates

被引:1
|
作者
Cetin, Ahmet [1 ]
Bircan, Durmus Ali [1 ]
机构
[1] Cukurova Univ, Dept Mech Engn, TR-01330 Adana, Turkey
关键词
Trabecular bone properties; pedicle screw pull-out performance; Johnson-Cook (JC) material model; finite element analysis (FEA); bone biomechanics; CANCELLOUS BONE; CORTICAL BONE; STRENGTH; BEHAVIOR; MODEL; BIOMECHANICS; COMPRESSION; FIXATION; FRACTURE; FAILURE;
D O I
10.1177/09544119211044560
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biomedical experimental studies such as pull-out (PO), screw loosening experience variability mechanical properties of fresh bone, legal procedures of cadaver bone samples and time-consuming problems. Finite Element Method (FEM) could overcome experimental problems in biomechanics. However, material modelling of bone is quite difficult, which has viscoelastic and viscoplastic properties. The study presents a bone material model which is constructed at the strain rates with the Johnson-Cook (JC) material model, one of the robust constitutive material models. The JC material constants of trabecular bone are determined by the curve fitting method at strain rates for the 3D PO finite element simulation, which defines the screw-bone interface relationship. The PO simulation is performed using the Abaqus/CAE software program. Bone fracture mechanisms are simulated with dynamic/explicit solutions during the PO phenomenon. The paper exposes whether the strain rate has effects on the PO performance. Moreover, simulation reveals the relationship between pedicle screw diameter and PO performance. The results obtained that the maximum pull-out force (POF) improves as both the screw diameter and the strain rate increase. For 5.5 mm diameter pedicle screw POFs were 487, 517 and 1708 N at strain rate 0.00015, 0.015 and 0.015 s(-1), respectively. The FOFs obtained from the simulation of the other screw were 730, 802 and 2008 N at strain rates 0.00015, 0.0015 and 0.015, respectively. PO phenomenon was also simulated realistically in the finite element analysis (FEA).
引用
收藏
页码:134 / 144
页数:11
相关论文
共 50 条
  • [21] 3D FINITE ELEMENT SIMULATION OF PULL OUT FORCE OF TiNiFe SHAPE MEMORY PIPE COUPLING WITH INNER CONVEX
    Zhang Huibo
    Jin Wei
    Yang Rui
    ACTA METALLURGICA SINICA, 2012, 48 (12) : 1520 - 1524
  • [22] Mesoscale simulation of pull-out performance for corroded reinforcement with stirrup confinement in concrete by 3D RBSM
    Avadh, Kumar
    Jiradilok, Punyawut
    Bolander, John E.
    Nagai, Kohei
    CEMENT & CONCRETE COMPOSITES, 2021, 116
  • [23] A novel personalized homogenous finite element model to predict the pull-out strength of cancellous bone screws
    Rouyin, Alireza
    Einafshar, Mohammadjavad
    Arjmand, Navid
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [24] A NEW 3-DIMENSIONAL INTERFACE (CONTACT) ELEMENT FOR FIBER PULL-OUT BEHAVIOR IN COMPOSITES
    FAFARD, MM
    BANTHIA, N
    COMPUTERS & STRUCTURES, 1992, 44 (04) : 753 - 764
  • [25] Meso-level 3d numerical study on single fiber pull-out test for interface heterogeniety
    Zhang, Y. F.
    Zeng, X. R.
    MECHANICS AND ARCHITECTURAL DESIGN, 2017, : 162 - 168
  • [26] Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population
    Rahadyan Magetsari
    Tedjo Rukmoyo
    Marda Ade Saputra
    Yudha Mathan Sakti
    BMC Research Notes, 15
  • [27] Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population
    Magetsari, Rahadyan
    Rukmoyo, Tedjo
    Saputra, Marda Ade
    Sakti, Yudha Mathan
    BMC RESEARCH NOTES, 2022, 15 (01)
  • [28] Bearing capacity of reinforced foundation subjected to pull-out loading: 3D model tests and numerical simulation
    Nakai, T.
    Zhang, F.
    Hinokio, A.
    Shahin, H. M.
    Kikurnoto, M.
    Yonaha, S.
    Nishio, A.
    NEW HORIZONS IN EARTH REINFORCEMENT, 2008, : 457 - 463
  • [29] Analysis on the effect of half angle on the displacement of pedicle screw during axial pull-out test in cancellous bone using 2d axisymmetric fe model
    Makaram H.
    Swaminathan R.
    Biomedical Sciences Instrumentation, 2021, 57 (02) : 153 - 158
  • [30] Effects of 3D discrete soil nail inclusion on pull-out, with implications for design
    Tan, S. A.
    Dasari, G. R.
    Lee, C. H.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-GROUND IMPROVEMENT, 2005, 9 (03) : 119 - 125