Improvement of Image Quality of Low Radiation Dose Abdominal CT by Increasing Contrast Enhancement

被引:37
|
作者
Watanabe, Haruo [1 ]
Kanematsu, Masayuki [1 ,2 ]
Miyoshi, Toshiharu [2 ]
Goshima, Satoshi [1 ]
Kondo, Hiroshi [1 ]
Moriyama, Noriyuki [3 ]
Bae, Kyongtae T. [4 ]
机构
[1] Gifu Univ Hosp, Dept Radiol, Gifu 5011194, Japan
[2] Gifu Univ Hosp, Serv Radiol, Gifu 5011194, Japan
[3] Natl Canc Ctr Hosp, Res Ctr Canc Prevent & Screening, Tsukiji, Japan
[4] Univ Pittsburgh, Med Ctr, Dept Radiol, Pittsburgh, PA USA
关键词
abdominal CT; contrast enhancement; image noise; image quality; radiation dose; LOW TUBE VOLTAGE; MODULATION;
D O I
10.2214/AJR.10.4456
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the effects of noise index and contrast material dose on radiation dose, contrast enhancement, image noise, and image quality in abdominal CT. SUBJECTS AND METHODS. Contrast-enhanced abdominal CT with tube current modulation was performed on 195 patients. The patients were prospectively randomized into three groups of equal size (protocol A, noise index of 12 HU and 521 mg I/kg; protocol B, 15 HU and 521 mg I/kg; protocol C, 15 HU and 600 mg I/kg). Scanning was initiated 5 and 45 seconds after aortic enhancement reached 100 HU. Attenuation was measured in the aorta, portal vein, and liver. Transverse CT images were qualitatively graded for diagnostic acceptability and image noise. Arterial phase volume-rendered and multiplanar reformatted (MPR) images and portal venous phase MPR CT angiograms were qualitatively graded for depiction of vessels. Contrast enhancement, objective image noise, radiation dose, and qualitative grades were analyzed and compared among the three groups. RESULTS. The contrast enhancement values of the aorta, portal vein, and liver were higher in protocol C than in protocols A and B (p < 0.05). Objective image noise was greater in protocols B and C than in protocol A (p < 0.05). The radiation dose in protocols B and C was 31-32% lower than in protocol A (p < 0.001). Depiction of vessels, diagnostic acceptability, and subjective image noise were comparable in protocols A and C. CONCLUSION. Use of higher contrast enhancement can compensate for the degradation of image quality resulting from use of a low radiation dose for CT.
引用
下载
收藏
页码:986 / 992
页数:7
相关论文
共 50 条
  • [31] Image Quality Improvement of Low-dose Abdominal CT Using Deep Learning Image Reconstruction Compared With the Second Generation Iterative Reconstruction
    Kang, Hyo-Jin
    Min Lee, Jeong
    Park, Sae Jin
    Lee, Sang Min
    Joo, Ijin
    Yoon, Jeong Hee
    Current Medical Imaging, 2024, 20
  • [32] Automatic Pancreas Segmentation in Abdominal CT Image with Contrast Enhancement Block
    Pan, Shengxue
    Xiang, Dehui
    Bian, Yun
    Lu, Jianping
    Jiang, Hui
    Zheng, Jianming
    MEDICAL IMAGING 2021: IMAGE PROCESSING, 2021, 11596
  • [33] Image Quality Improvement of Low-dose Abdominal CT using Deep Learning Image Reconstruction Compared with the Second Generation Iterative Reconstruction
    Kang, Hyo-Jin
    Lee, Jeong Min
    Park, Sae Jin
    Lee, Sang Min
    Joo, Ijin
    Yoon, Jeong Hee
    CURRENT MEDICAL IMAGING, 2024, 20
  • [34] Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 KV)
    Li, Zhen-lin
    Li, Hang
    Zhang, Kai
    Li, Wang-jiang
    Chen, Xian
    Wu, Bin
    Song, Bin
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1906 - 1913
  • [35] Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 KV)
    Zhen-lin Li
    Hang Li
    Kai Zhang
    Wang-jiang Li
    Xian Chen
    Bin Wu
    Bin Song
    European Radiology, 2014, 24 : 1906 - 1913
  • [36] Comparison of radiation dose, contrast enhancement and image quality of prospective ECG-Gated CT coronary angiography: Single versus dual source CT
    Liang, C. R.
    Ong, C. C.
    Chai, P.
    Teo, L. L. S.
    RADIOGRAPHY, 2021, 27 (03) : 831 - 839
  • [37] Comparative study of image quality and radiation dose in thoracic-abdominal-pelvic CT Enhancement with different tube voltages and reconstruction algorithms
    Ding, Wei
    Liu, Zi-yan
    Ma, Ze-peng
    Zhang, Tian-le
    Zhao, Yong-Xia
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (04)
  • [38] Abdominal multislice CT for obese patients: Effect on image quality and radiation dose in a phantom study
    Schindera, Sebastian T.
    Nelson, Rendon C.
    Lee, Ellie R.
    DeLong, David M.
    Ngyen, Giao
    Toncheva, Greta
    Yoshizumi, Terry T.
    ACADEMIC RADIOLOGY, 2007, 14 (04) : 486 - 494
  • [39] Evaluating Image Quality and Radiation Dose in Low-Dose Thoraco-Abdominal CT Angiography with a Tin Filter for Patients with Aortic Disease
    Oh, Chang Hoon
    Cho, Soo Buem
    Kwon, Hyeyoung
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (04)
  • [40] Image quality and radiation dose of low-tube-voltage CT with reduced contrast media for right adrenal vein imaging
    Takahashi, Yuki
    Ota, Hideki
    Omura, Kensuke
    Dendo, Yutaka
    Otani, Katharina
    Matsuura, Tomonori
    Kitami, Masahiro
    Seiji, Kazumasa
    Tezuka, Yuta
    Nezu, Masahiro
    Ono, Yoshikiyo
    Morimoto, Ryo
    Satoh, Fumitoshi
    Takase, Kei
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 98 : 150 - 157