Thermal Response to High-Power Holmium Laser Lithotripsy

被引:118
|
作者
Aldoukhi, Ali H. [1 ]
Ghani, Khurshid R. [1 ]
Hall, Timothy L. [2 ]
Roberts, William W. [1 ,2 ]
机构
[1] Univ Michigan, Dept Urol, Div Endourol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
holmium laser; temperature; lithotripsy; ureteroscopy; YAG LASER;
D O I
10.1089/end.2017.0679
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The aim of this study was to investigate caliceal fluid temperature changes during holmium laser activation/lithotripsy using settings up to 40 W power output with different irrigation flow rates. Materials and Methods: The experimental system consisted of a glass test tube (diameter 10mm/length 75mm) filled with deionized water, to mimic a calix. Real-time temperature was recorded using a thermocouple (Physitemp, NJ) positioned 5mm from the bottom of the tube. A 200m laser fiber (Flexiva; Boston Scientific, MA) was introduced through the working channel of a disposable ureteroscope (LithoVue; Boston Scientific) and the laser fiber tip was positioned 15mm above the bottom of the test tube. Deionized water irrigation (room temperature) through the working channel of the ureteroscope was delivered at flow rates of 0, 7-8, 14-15, and 38-40mL/minute. A 120-W holmium laser (pulse 120; Lumenis, CA) was used. The following settings were explored: 0.5Jx10Hz, 1.0Jx10Hz, 0.5Jx20Hz, 1.0Jx20Hz, 0.5Jx40Hz, 1.0Jx40Hz, and 0.5Jx80Hz. During each experiment, the laser was activated continuously for 60 seconds. Results: Temperature increased with increasing laser power output and decreasing irrigation flow rate. The highest temperature, 70.3 degrees C (standard deviation 2.7), occurred with laser setting of 1.0Jx40Hz and no irrigation after 60 seconds of continuous laser firing. None of the tested laser settings and irrigation parameters produced temperature exceeding 51 degrees C when activated for only 10 seconds of continuous laser firing. Conclusion: High-power holmium settings fired in long bursts with low irrigation flow rates can generate high fluid temperatures in a laboratory caliceal model. Awareness of this risk allows urologist to implement a variety of techniques (higher irrigation flow rates, intermittent laser activation, and potentially cooled irrigation fluid) to control and mitigate thermal effects during holmium laser lithotripsy.
引用
收藏
页码:1308 / 1312
页数:5
相关论文
共 50 条
  • [41] Holmium laser lithotripsy for ureteral calculi
    不详
    JOURNAL OF ENDOUROLOGY, 2005, 19 : A207 - A207
  • [42] Holmium laser lithotripsy of bladder calculi
    Beaghler, MA
    Poon, MW
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS VIII, PROCEEDINGS OF, 1998, 3245 : 120 - 122
  • [43] Ureteral lithotripsy with the holmium:YAG laser
    Sayer, Jeanie
    Johnson, Douglas E.
    Price, Roger E.
    Cromeens, Douglas M.
    Journal of Clinical Laser Medicine and Surgery, 1993, 11 (02):
  • [44] Intracorporeal lithotripsy with the holmium:YAG laser
    Yiu, MK
    Liu, PL
    Yiu, TF
    Chan, AYT
    JOURNAL OF UROLOGY, 1997, 158 (01): : 186 - 186
  • [45] Comparing outcomes of thulium fiber laser versus high-power Holmium:YAG laser lithotripsy in pediatric patients managed with RIRS for kidney stones. A multicenter retrospective study
    Candela, Luigi
    Solano, Catalina
    Castellani, Daniele
    Teoh, Jeremy Y.
    Tanidir, Yiloren
    Fong, Khi Y.
    Vaddi, Chandramohan
    Sinha, Mriganka Mani
    Ragoori, Deepak
    Somani, Bhaskar K.
    Traxer, Olivier
    Gauhar, Vineet
    MINERVA PEDIATRICS, 2023,
  • [46] The Rise and Fall of High Temperatures During Ureteroscopic Holmium Laser Lithotripsy
    Winship, Brenton
    Wollin, Daniel
    Carlos, Evan
    Peters, Chloe
    Li, Jingqiu
    Terry, Russell
    Boydston, Kohldon
    Preminger, Glenn M.
    Lipkin, Michael E.
    JOURNAL OF ENDOUROLOGY, 2019, 33 (10) : 794 - 799
  • [47] Effects of Thermal Insulation on Recovery and Comfort of Patients Undergoing Holmium Laser Lithotripsy
    Chen, Xiaoling
    He, Libin
    Yu, Xiao
    Bo, Yuqing
    Yu, Lei
    Chen, Qiumei
    Zhao, Zhuoer
    MEDICAL SCIENCE MONITOR, 2024, 30
  • [48] HIGH FREQUENCY FOR DUSTING DURING HOLMIUM LASER LITHOTRIPSY: DOES IT MATTER?
    Aldoukhi, Ali H.
    Black, Kristian M.
    Hall, Timothy L.
    Roberts, William W.
    Ghani, Khurshid R.
    JOURNAL OF UROLOGY, 2019, 201 (04): : E58 - E59
  • [49] Low-power versus high-power laser for holmium laser enucleation of prostate: systematic review and meta-analysis
    Liping Chen
    Changqing Chen
    Congran Li
    Zhijia Liu
    Haixia Qiu
    Hongwei Bai
    World Journal of Urology, 43 (1)