Thermal Response to High-Power Holmium Laser Lithotripsy

被引:118
|
作者
Aldoukhi, Ali H. [1 ]
Ghani, Khurshid R. [1 ]
Hall, Timothy L. [2 ]
Roberts, William W. [1 ,2 ]
机构
[1] Univ Michigan, Dept Urol, Div Endourol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
holmium laser; temperature; lithotripsy; ureteroscopy; YAG LASER;
D O I
10.1089/end.2017.0679
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The aim of this study was to investigate caliceal fluid temperature changes during holmium laser activation/lithotripsy using settings up to 40 W power output with different irrigation flow rates. Materials and Methods: The experimental system consisted of a glass test tube (diameter 10mm/length 75mm) filled with deionized water, to mimic a calix. Real-time temperature was recorded using a thermocouple (Physitemp, NJ) positioned 5mm from the bottom of the tube. A 200m laser fiber (Flexiva; Boston Scientific, MA) was introduced through the working channel of a disposable ureteroscope (LithoVue; Boston Scientific) and the laser fiber tip was positioned 15mm above the bottom of the test tube. Deionized water irrigation (room temperature) through the working channel of the ureteroscope was delivered at flow rates of 0, 7-8, 14-15, and 38-40mL/minute. A 120-W holmium laser (pulse 120; Lumenis, CA) was used. The following settings were explored: 0.5Jx10Hz, 1.0Jx10Hz, 0.5Jx20Hz, 1.0Jx20Hz, 0.5Jx40Hz, 1.0Jx40Hz, and 0.5Jx80Hz. During each experiment, the laser was activated continuously for 60 seconds. Results: Temperature increased with increasing laser power output and decreasing irrigation flow rate. The highest temperature, 70.3 degrees C (standard deviation 2.7), occurred with laser setting of 1.0Jx40Hz and no irrigation after 60 seconds of continuous laser firing. None of the tested laser settings and irrigation parameters produced temperature exceeding 51 degrees C when activated for only 10 seconds of continuous laser firing. Conclusion: High-power holmium settings fired in long bursts with low irrigation flow rates can generate high fluid temperatures in a laboratory caliceal model. Awareness of this risk allows urologist to implement a variety of techniques (higher irrigation flow rates, intermittent laser activation, and potentially cooled irrigation fluid) to control and mitigate thermal effects during holmium laser lithotripsy.
引用
收藏
页码:1308 / 1312
页数:5
相关论文
共 50 条
  • [21] Comments on Thermal effect of holmium laser lithotripsy under ureteroscopy
    Teng JingFei
    Wang Kai
    Ai Xing
    中华医学杂志英文版, 2020, 133 (01) : 86 - 87
  • [22] Thermal condition of high-power laser diodes
    Bezotosnyi, V. V.
    Krokhin, O. N.
    Oleshchenko, V. A.
    Pevtsov, V. F.
    Popov, Yu. M.
    Cheshev, E. A.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2015, 42 (03) : 88 - 92
  • [23] Thermal condition of high-power laser diodes
    V. V. Bezotosnyi
    O. N. Krokhin
    V. A. Oleshchenko
    V. F. Pevtsov
    Yu. M. Popov
    E. A. Cheshev
    Bulletin of the Lebedev Physics Institute, 2015, 42 : 88 - 92
  • [24] THERMAL INSTABILITY IN HIGH-POWER LASER DISCHARGES
    JACOB, JH
    MANI, SA
    APPLIED PHYSICS LETTERS, 1975, 26 (02) : 53 - 55
  • [25] THERMAL INSTABILITY IN HIGH-POWER LASER DISCHARGES
    JACOB, JH
    MANI, SA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (02): : 233 - 233
  • [26] HIGH-POWER LASER PROPAGATION - THERMAL BLOOMING
    SMITH, DC
    PROCEEDINGS OF THE IEEE, 1977, 65 (12) : 1679 - 1714
  • [27] High-power Holmium:Yag lithotripsy in bladder urolithiasis: Is it safe and effective? A combined clinical and experimental study
    Pagonis, Konstantinos
    Katsakiori, Paraskevi
    Peteinaris, Angelis
    Tatanis, Vasileios
    Tsaturyan, Arman
    Costa, Gabriel Faria
    Faitatziadis, Solon
    Vagionis, Athanasios
    Natsos, Anastasios
    Gkeka, Kristiana
    Obaidat, Mohammed
    Spinos, Theodoros
    Vrettos, Theofanis
    Liatsikos, Evangelos
    Kallidonis, Panagiotis
    ARAB JOURNAL OF UROLOGY, 2024, 22 (03) : 145 - 151
  • [28] PROSTATE ENUCLEATION, BETTER WITH LOW OR HIGH-POWER HOLMIUM LASER? A SYSTEMATIC REVIEW
    Scoffone, Cesare Marco
    Cracco, Cecilia Maria
    ARCHIVOS ESPANOLES DE UROLOGIA, 2020, 73 (08): : 745 - 752
  • [30] Adjusting the optical path of high-power holmium laser based on servo motor
    Chen Chuncheng
    Lu Zhiyi
    Su Rui
    Fan Yisong
    Guo Qiang
    ICOSM 2020: OPTOELECTRONIC SCIENCE AND MATERIALS, 2020, 11606