Initial Results of Simultaneous PET/MRI Experiments with an MRI-Compatible Silicon Photomultiplier PET Scanner

被引:153
|
作者
Yoon, Hyun Suk [1 ,2 ,3 ]
Ko, Guen Bae [1 ,2 ]
Kwon, Sun Il [1 ,4 ]
Lee, Chan Mi [1 ,2 ]
Ito, Mikiko [1 ,3 ]
Song, In Chan [3 ,5 ]
Lee, Dong Soo [1 ,3 ,6 ]
Hong, Seong Jong [7 ]
Lee, Jae Sung [1 ,2 ,3 ,4 ,8 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Nucl Med, 28 Yungundong, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Biomed Sci, Seoul 110744, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul 110744, South Korea
[4] Seoul Natl Univ, Interdisciplinary Program Radiat Appl Life Sci, Seoul 110744, South Korea
[5] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[6] Seoul Natl Univ, Dept Mol Med & Biopharmaceut Sci, Seoul 110744, South Korea
[7] Eulji Univ, Dept Radiol Sci, Gyeonggi Do, South Korea
[8] Seoul Natl Univ, Dept Brain & Cognit Sci, Seoul 110744, South Korea
关键词
PET/MRI; MR-PET; silicon photomultiplier (SiPM); Geiger-mode APD (G-APD); hybrid imaging; POSITRON-EMISSION-TOMOGRAPHY; SOLID-STATE PHOTOMULTIPLIERS; FEASIBILITY; DETECTOR; SYSTEM;
D O I
10.2967/jnumed.111.097501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The most investigated semiconductor photosensor for MRI-compatible PET detectors is the avalanche photodiode (APD). However, the silicon photomultiplier (SiPM), also called the Geiger-mode APD, is gaining attention in the development of the next generation of PET/MRI systems because the SiPM has much better performance than the APD. We have developed an MRI-compatible PET system based on multichannel SiPM arrays to allow simultaneous PET/MRI. Methods: The SiPM PET scanner consists of 12 detector modules with a ring diameter of 13.6 cm and an axial extent of 3.2 cm. In each detector module, 4 multichannel SiPM arrays (with 4 x 4 channels arranged in a 2 x 2 array to yield 8 x 8 channels) were coupled with 20 x 18 Lu1.9Gd0.1SiO5:Ce crystals (each crystal is 1.5 x 1.5 x 7 mm) and mounted on a charge division network for multiplexing 64 signals into 4 position signals. Each detector module was enclosed in a shielding box to reduce interference between the PET and MRI scanners, and the temperature inside the box was monitored for correction of the temperature-dependent gain variation of the SiPM. The PET detector signal was routed to the outside of the MRI room and processed with a field programmable gate array-based data acquisition system. MRI compatibility tests and simultaneous PET/MRI acquisitions were performed inside a 3-T clinical MRI system with 4-cm loop receiver coils that were built into the SiPM PET scanner. Interference between the imaging systems was investigated, and phantom and mouse experiments were performed. Results: No radiofrequency interference on the PET signal or degradation in the energy spectrum and flood map was shown during simultaneous PET/MRI. The quality of the MRI scans acquired with and without the operating PET showed only slight degradation. The results of phantom and mouse experiments confirmed the feasibility of this system for simultaneous PET/MRI. Conclusion: Simultaneous PET/MRI was possible with a multichannel SiPM-based PET scanner, with no radiofrequency interference on PET signals or images and only slight degradation of the MRI scans.
引用
收藏
页码:608 / 614
页数:7
相关论文
共 50 条
  • [41] PET, MRI, and simultaneous PET/MRI in the development of diagnostic and therapeutic strategies for glioma
    Puttick, Simon
    Bell, Christopher
    Dowson, Nicholas
    Rose, Stephen
    Fay, Michael
    DRUG DISCOVERY TODAY, 2015, 20 (03) : 306 - 317
  • [42] Simultaneous PET/MR imaging with a MR-compatible SiPM PET scanner
    Yoon, Hyun Suk
    Ko, Guen Bae
    Kwon, Sun Il
    Lee, Chan Mi
    Ito, Mikiko
    Song, In Chan
    Lee, Dong Soo
    Hong, Seong Jong
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [43] The mobile PET insert for simultaneous PET/MRI imaging
    Zielinski, M.
    Glowacz, B.
    Alfs, D.
    Bednarski, T.
    Bialas, P.
    Czerwinski, E.
    Gajos, A.
    Gorgol, M.
    Jasinska, B.
    Kaminska, D.
    Kaplon, L.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krzemien, W.
    Kubicz, E.
    Mohammed, M.
    Pawlik-Niedzwiecka, M.
    Niedzwiecki, S.
    Palka, M.
    Raczynski, L.
    Rudy, Z.
    Rundel, O.
    Sharma, N. G.
    Silarski, M.
    Slomski, A.
    Strzelecki, A.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Moskal, P.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S117 - S118
  • [44] New shielding configurations for a simultaneous PET/MRI scanner at 7T
    Peng, Bo J.
    Wu, Yibao
    Cherry, Simon R.
    Walton, Jeffrey H.
    JOURNAL OF MAGNETIC RESONANCE, 2014, 239 : 50 - 56
  • [45] New scanner allows combined PET and MRI
    Lytle, David
    Biophotonics International, 1997, 4 (01):
  • [46] Initial evaluation of a practical PET respiratory motion correction method in clinical simultaneous PET/MRI
    Richard Manber
    Kris Thielemans
    Brian Hutton
    Anna Barnes
    Sebastien Ourselin
    Simon Arridge
    Celia O'Meara
    David Atkinson
    EJNMMI Physics, 1 (Suppl 1)
  • [47] Development of a PET Scanner for Simultaneously Imaging Small Animals with MRI and PET
    Thompson, Christopher J.
    Goertzen, Andrew L.
    Thiessen, Jonathan D.
    Bishop, Daryl
    Stortz, Greg
    Kozlowski, Piotr
    Retiere, Fabrice
    Zhang, Xuezhu
    Sossi, Vesna
    SENSORS, 2014, 14 (08) : 14654 - 14671
  • [48] Is Glucagon Administration Compatible With FDG PET/MRI?
    Maucherat, Bruno
    Movassaghi, Roshanack
    Fleury, Vincent
    Le Thiec, Maelle
    Geffroy, Delphine
    Labbe-Devilliers, Catherine
    Rousseau, Caroline
    CLINICAL NUCLEAR MEDICINE, 2022, 47 (08) : 730 - 731
  • [49] Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner
    Peng, Bo J.
    Walton, Jeffrey H.
    Cherry, Simon R.
    Willig-Onwuachi, Jacob
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01): : 265 - 280
  • [50] PET Image Quality Improvement for Simultaneous PET/MRI with a Lightweight MRI Surface Coil
    Deller, Timothy W.
    Mathew, Nicholas K.
    Hurley, Samuel A.
    Bobb, Chad M.
    McMillan, Alan B.
    RADIOLOGY, 2021, 298 (01) : 166 - 172