Initial Results of Simultaneous PET/MRI Experiments with an MRI-Compatible Silicon Photomultiplier PET Scanner

被引:152
|
作者
Yoon, Hyun Suk [1 ,2 ,3 ]
Ko, Guen Bae [1 ,2 ]
Kwon, Sun Il [1 ,4 ]
Lee, Chan Mi [1 ,2 ]
Ito, Mikiko [1 ,3 ]
Song, In Chan [3 ,5 ]
Lee, Dong Soo [1 ,3 ,6 ]
Hong, Seong Jong [7 ]
Lee, Jae Sung [1 ,2 ,3 ,4 ,8 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Nucl Med, 28 Yungundong, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Biomed Sci, Seoul 110744, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul 110744, South Korea
[4] Seoul Natl Univ, Interdisciplinary Program Radiat Appl Life Sci, Seoul 110744, South Korea
[5] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[6] Seoul Natl Univ, Dept Mol Med & Biopharmaceut Sci, Seoul 110744, South Korea
[7] Eulji Univ, Dept Radiol Sci, Gyeonggi Do, South Korea
[8] Seoul Natl Univ, Dept Brain & Cognit Sci, Seoul 110744, South Korea
关键词
PET/MRI; MR-PET; silicon photomultiplier (SiPM); Geiger-mode APD (G-APD); hybrid imaging; POSITRON-EMISSION-TOMOGRAPHY; SOLID-STATE PHOTOMULTIPLIERS; FEASIBILITY; DETECTOR; SYSTEM;
D O I
10.2967/jnumed.111.097501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The most investigated semiconductor photosensor for MRI-compatible PET detectors is the avalanche photodiode (APD). However, the silicon photomultiplier (SiPM), also called the Geiger-mode APD, is gaining attention in the development of the next generation of PET/MRI systems because the SiPM has much better performance than the APD. We have developed an MRI-compatible PET system based on multichannel SiPM arrays to allow simultaneous PET/MRI. Methods: The SiPM PET scanner consists of 12 detector modules with a ring diameter of 13.6 cm and an axial extent of 3.2 cm. In each detector module, 4 multichannel SiPM arrays (with 4 x 4 channels arranged in a 2 x 2 array to yield 8 x 8 channels) were coupled with 20 x 18 Lu1.9Gd0.1SiO5:Ce crystals (each crystal is 1.5 x 1.5 x 7 mm) and mounted on a charge division network for multiplexing 64 signals into 4 position signals. Each detector module was enclosed in a shielding box to reduce interference between the PET and MRI scanners, and the temperature inside the box was monitored for correction of the temperature-dependent gain variation of the SiPM. The PET detector signal was routed to the outside of the MRI room and processed with a field programmable gate array-based data acquisition system. MRI compatibility tests and simultaneous PET/MRI acquisitions were performed inside a 3-T clinical MRI system with 4-cm loop receiver coils that were built into the SiPM PET scanner. Interference between the imaging systems was investigated, and phantom and mouse experiments were performed. Results: No radiofrequency interference on the PET signal or degradation in the energy spectrum and flood map was shown during simultaneous PET/MRI. The quality of the MRI scans acquired with and without the operating PET showed only slight degradation. The results of phantom and mouse experiments confirmed the feasibility of this system for simultaneous PET/MRI. Conclusion: Simultaneous PET/MRI was possible with a multichannel SiPM-based PET scanner, with no radiofrequency interference on PET signals or images and only slight degradation of the MRI scans.
引用
收藏
页码:608 / 614
页数:7
相关论文
共 50 条
  • [21] A simultaneous PET/MRI scanner based on RatCAP in small animals
    Schyler, D.
    Vaska, P.
    Tomasi, D.
    Woody, C.
    Maramraju, S-H
    Southekal, S.
    Pratte, J-F
    Junnarkar, S.
    Solis-Najera, S.
    Krishnamoorthy, S.
    Kriplani, A.
    Stoll, S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3256 - +
  • [22] Challenges in Acquiring Clinical Simultaneous SPECT-MRI on a PET-MRI Scanner
    Morahan, Ashley J.
    D'Adda, Ilenia
    Erlandsson, Kjell
    Carminati, Marco
    Rega, Marilena
    Walls, Darren
    Fiorini, Carlo
    Hutton, Brian F.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (07) : 755 - 763
  • [23] Development of an MRI-compatible catheter for pacing the heart: Initial in vitro and in vivo results
    Jerzewski, A
    Pattynama, PMT
    Steendijk, P
    Doornbos, J
    deRoos, A
    Baan, J
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (06) : 948 - 949
  • [24] An MRI-compatible defibrillator: initial testing in volunteers and swine
    Ehud J Schmidt
    Ronald D Watkins
    Menekhem M Zviman
    Michael Guttman
    Wei Wang
    Henry Halperin
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [25] MRI-compatible incubation chamber for cell culture experiments
    Schwenzer, NF
    Grönewäller, EF
    Rodegerdts, E
    Kehlbach, R
    Duda, SH
    Claussen, CD
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (01) : 70 - 76
  • [26] Results from Prototype II of the BNL Simultaneous PET-MRI Dedicated Breast Scanner
    Ravindranath, B.
    Junnarkar, S. S.
    Purschke, M. L.
    Maramraju, S. H.
    Hong, X.
    Tomasi, D.
    Bennett, D.
    Cheng, K.
    Southekal, S. S.
    Stoll, S. P.
    Pratte, J. -F.
    Vaska, P.
    Woody, C. L.
    Schlyer, D. J.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3315 - +
  • [27] Simultaneous FET-PET and fMRI in brain tumors using a PET/MRI hybrid scanner
    Herzog, Hans
    Stoffels, Gabriele
    Kaffanke, Joachim
    Tellmann, Lutz
    Weirich, Christoph
    Kops, Elena Rota
    Neuner, Irene
    Scheins, Juergen
    Shah, Nadim
    Langen, Karl
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [28] Markerless motion tracking and correction for PET, MRI, and simultaneous PET/MRI
    Slipsager, Jakob M.
    Ellegaard, Andreas H.
    Glimberg, Stefan L.
    Paulsen, Rasmus R.
    Tisdall, M. Dylan
    Wighton, Paul
    van der Kouwe, Andre
    Marner, Lisbeth
    Henriksen, Otto M.
    Law, Ian
    Olesen, Oline V.
    PLOS ONE, 2019, 14 (04):
  • [29] Development of MR Compatible Preclinical PET Insert and Initial Results in a 9.4T MRI
    Lee, Sangwon
    Choi, Yong
    Im, Ki Chun
    Jung, Jin Ho
    Kim, Sangsu
    Choi, Jaewoo
    Lee, Hwunjae
    Huh, Yong-Min
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [30] Dynamic PSMA PET/MRI imaging: initial results
    Gammel, M.
    Rauscher, I.
    Eiber, M.
    Weber, W. A.
    Nekolla, S. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S484 - S484