Initial Results of Simultaneous PET/MRI Experiments with an MRI-Compatible Silicon Photomultiplier PET Scanner

被引:152
|
作者
Yoon, Hyun Suk [1 ,2 ,3 ]
Ko, Guen Bae [1 ,2 ]
Kwon, Sun Il [1 ,4 ]
Lee, Chan Mi [1 ,2 ]
Ito, Mikiko [1 ,3 ]
Song, In Chan [3 ,5 ]
Lee, Dong Soo [1 ,3 ,6 ]
Hong, Seong Jong [7 ]
Lee, Jae Sung [1 ,2 ,3 ,4 ,8 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Nucl Med, 28 Yungundong, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Biomed Sci, Seoul 110744, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul 110744, South Korea
[4] Seoul Natl Univ, Interdisciplinary Program Radiat Appl Life Sci, Seoul 110744, South Korea
[5] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[6] Seoul Natl Univ, Dept Mol Med & Biopharmaceut Sci, Seoul 110744, South Korea
[7] Eulji Univ, Dept Radiol Sci, Gyeonggi Do, South Korea
[8] Seoul Natl Univ, Dept Brain & Cognit Sci, Seoul 110744, South Korea
关键词
PET/MRI; MR-PET; silicon photomultiplier (SiPM); Geiger-mode APD (G-APD); hybrid imaging; POSITRON-EMISSION-TOMOGRAPHY; SOLID-STATE PHOTOMULTIPLIERS; FEASIBILITY; DETECTOR; SYSTEM;
D O I
10.2967/jnumed.111.097501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The most investigated semiconductor photosensor for MRI-compatible PET detectors is the avalanche photodiode (APD). However, the silicon photomultiplier (SiPM), also called the Geiger-mode APD, is gaining attention in the development of the next generation of PET/MRI systems because the SiPM has much better performance than the APD. We have developed an MRI-compatible PET system based on multichannel SiPM arrays to allow simultaneous PET/MRI. Methods: The SiPM PET scanner consists of 12 detector modules with a ring diameter of 13.6 cm and an axial extent of 3.2 cm. In each detector module, 4 multichannel SiPM arrays (with 4 x 4 channels arranged in a 2 x 2 array to yield 8 x 8 channels) were coupled with 20 x 18 Lu1.9Gd0.1SiO5:Ce crystals (each crystal is 1.5 x 1.5 x 7 mm) and mounted on a charge division network for multiplexing 64 signals into 4 position signals. Each detector module was enclosed in a shielding box to reduce interference between the PET and MRI scanners, and the temperature inside the box was monitored for correction of the temperature-dependent gain variation of the SiPM. The PET detector signal was routed to the outside of the MRI room and processed with a field programmable gate array-based data acquisition system. MRI compatibility tests and simultaneous PET/MRI acquisitions were performed inside a 3-T clinical MRI system with 4-cm loop receiver coils that were built into the SiPM PET scanner. Interference between the imaging systems was investigated, and phantom and mouse experiments were performed. Results: No radiofrequency interference on the PET signal or degradation in the energy spectrum and flood map was shown during simultaneous PET/MRI. The quality of the MRI scans acquired with and without the operating PET showed only slight degradation. The results of phantom and mouse experiments confirmed the feasibility of this system for simultaneous PET/MRI. Conclusion: Simultaneous PET/MRI was possible with a multichannel SiPM-based PET scanner, with no radiofrequency interference on PET signals or images and only slight degradation of the MRI scans.
引用
收藏
页码:608 / 614
页数:7
相关论文
共 50 条
  • [1] Silicon photomultiplier modules for MRI-compatible PET
    Sul, Woo-Suk
    Kim, Hyoungtaek
    Cho, Gyuseong
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [2] Quantitative, Simultaneous PET/MRI for Intratumoral Imaging with an MRI-Compatible PET Scanner
    Ng, Thomas S. C.
    Bading, James R.
    Park, Ryan
    Sohi, Hargun
    Procissi, Daniel
    Colcher, David
    Conti, Peter S.
    Cherry, Simon R.
    Raubitschek, Andrew A.
    Jacobs, Russell E.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (07) : 1102 - 1109
  • [3] Initial tests of a prototype MRI-compatible PET imager
    Raylman, Raymond R.
    Majewski, Stan
    Lemieux, Susan
    Velan, S. Sendhil
    Kross, Brain
    Popov, Vladimir
    Smith, Mark F.
    Weisenberger, Andrew G.
    Wojcik, Randy
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 306 - 309
  • [4] Development of an MRI-compatible digital SiPM detector stack for simultaneous PET/MRI
    Duppenbecker, Peter M.
    Weissler, Bjoern
    Gebhardt, Pierre
    Schug, David
    Wehner, Jakob
    Marsden, Paul K.
    Schulz, Volkmar
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (01):
  • [5] Readout Technologies for the BNL-UPenn MRI-Compatible PET Scanner for Rodents
    Purschke, Martin L.
    Budassi, M.
    Cao, T.
    Fried, J.
    Gualtieri, E.
    Junnarkar, S. S.
    Karp, J. S.
    Maramraju, S. -H.
    O'Connor, P.
    Pratte, J. -P.
    Ravindranath, B.
    Schlyer, D.
    Stoll, S. P.
    Vaska, P.
    Woody, C.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 617 - 620
  • [6] A Promising Future: Comparable Imaging Capability of MRI-Compatible Silicon Photomultiplier and Conventional Photosensor Preclinical PET Systems
    Krizsan, Aron K.
    Lajtos, Imre
    Dahlbom, Magnus
    Daver, Freddie
    Emri, Miklos
    Kis, Sandor A.
    Opposits, Gabor
    Pohubi, Laszlo
    Potari, Norbert
    Hegyesi, Gyula
    Kalinka, Gabor
    Gal, Janos
    Imrek, Jozsef
    Nagy, Ferenc
    Valastyan, Ivan
    Kiraly, Beata
    Molnar, Jozsef
    Sanfilippo, Delfo
    Balkay, Laszlo
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (12) : 1948 - 1953
  • [7] Development of a simultaneous PET/MRI scanner
    Schlyer, D
    Rooney, W
    Woody, C
    Vaska, P
    Kriplani, A
    Stoll, S
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3419 - 3421
  • [8] Results from a simultaneous PET-MRI breast scanner
    Ravindranath, Bosky
    Junnarkar, Sachin
    Purschke, Martin
    Stoll, Sean
    Hong, Xiaole
    Huang, Pai-Jung
    Maramraju, Harsha
    Vaska, Paul
    Woody, Craig
    Schlyer, David
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [9] Simultaneous PET/MR body imaging in rats: initial experiences with an integrated PET/MRI scanner
    Mitsuaki Tatsumi
    Seiichi Yamamoto
    Masao Imaizumi
    Tadashi Watabe
    Yasukazu Kanai
    Masaaki Aoki
    Hiroki Kato
    Eku Shimosegawa
    Jun Hatazawa
    Annals of Nuclear Medicine, 2012, 26 : 444 - 449
  • [10] Simultaneous PET/MR body imaging in rats: initial experiences with an integrated PET/MRI scanner
    Tatsumi, Mitsuaki
    Yamamoto, Seiichi
    Imaizumi, Masao
    Watabe, Tadashi
    Kanai, Yasukazu
    Aoki, Masaaki
    Kato, Hiroki
    Shimosegawa, Eku
    Hatazawa, Jun
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (05) : 444 - 449