Wear analysis of retrieved ceramic-on-ceramic articulations in total hip arthroplasty: Femoral head makes contact with the rim of the socket outside of the bearing surface

被引:20
|
作者
Yamamoto, T
Saito, M
Ueno, M
Hananouchi, T
Tokugawa, Y
Yonenobu, K
机构
[1] Osaka Minami Med Ctr, Dept Orthopaed Surg, Kawachi Nagano 5868521, Japan
[2] Kyocera Corp, Bioceram Div, Kyoto, Japan
关键词
ceramic; implant retrieval; in vivo; total joint replacement; surface analysis;
D O I
10.1002/jbm.b.30215
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigated articular bearing surfaces retrieved from three patients with ceramic-on-ceramic total hip arthroplasties using high-quality alumina. The duration of implantation was 3.5, 3.0, and 2.5 years, respectively. Dislocation of the hip joint after implantation did not occur in any patients. The retrieved prostheses were examined by stereomicroscopy and scanning electron microscopy (SEM). In the main load-bearing area, no wear marks were seen in any sockets. However, in all three cases, stripe scars were observed at the rim of the alumina inlay under stereomicroscopy, despite the lack of indentation in the socket and the stem, which suggests impingement. Such scars were not observed on the load-bearing surface. Under SEM, the scars showed excessive wear, including material excavation, that has not been observed in conventional hip simulator experiments. These findings are similar to those of experiments in which a simulator was programmed to distract the femoral head from the socket. The present results suggest that the femoral head can separate from the socket without neck-socket impingement in vivo. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:301 / 307
页数:7
相关论文
共 50 条
  • [41] Mid-term results of ceramic-on-ceramic bearing extensively porous coated AML® total hip arthroplasty
    Moon, K. -H.
    Kang, J. -S.
    Lee, D. -J.
    Lee, S. -H.
    Kim, K. -H.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2007, : 211 - 218
  • [42] Ceramic-on-ceramic bearing surface and risk of revision due to dislocation after primary total hip replacement
    Sexton, S. A.
    Walter, W. L.
    Jackson, M. P.
    De Steiger, R.
    Stanford, T.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (11): : 1448 - 1453
  • [43] Large head ceramic-on-ceramic bearing in primary total hip arthroplasty: average 3-year follow-up of a multicentre study
    Lavigne, Martin
    Vendittoli, Pascal-Andre
    Virolainen, Petri
    Corten, Kristoff
    Martinez, Mariano
    Zicat, Bernard
    Peter, Viju
    Bloem, Rolf
    Miazzolo, Nicolas
    Remes, Ville
    HIP INTERNATIONAL, 2020, 30 (06) : 711 - 717
  • [44] Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic-on-ceramic total hip replacement
    Al-Hajjar, Mazen
    Leslie, Ian J.
    Tipper, Joanne
    Williams, Sophie
    Fisher, John
    Jennings, Louise M.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 95B (02) : 263 - 268
  • [45] Magnetic Resonance Imaging Findings Following Ceramic-on-Ceramic Total Hip Arthroplasty Using Modular Neck Femoral Components
    Takigami, Iori
    Ito, Yoshiki
    Miyagawa, Takaki
    Akiyama, Haruhiko
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2018, 76 (03): : 171 - 175
  • [46] No benefit on functional outcomes and dislocation rates by increasing head size to 36 mm in ceramic-on-ceramic total hip arthroplasty
    Lu, Yu-Der
    Yen, Shih-Hsiang
    Kuo, Feng-Chih
    Wang, Jun-Wen
    Wang, Ching-Jen
    BIOMEDICAL JOURNAL, 2015, 38 (06) : 538 - 543
  • [47] Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials
    Dongcai Hu
    Kai Tie
    Xiao Yang
    Yang Tan
    Mohammed Alaidaros
    Liaobin Chen
    Journal of Orthopaedic Surgery and Research, 10
  • [48] Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials
    Hu, Dongcai
    Tie, Kai
    Yang, Xiao
    Tan, Yang
    Alaidaros, Mohammed
    Chen, Liaobin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [49] Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty
    Callaway, GH
    Flynn, W
    Ranawat, CS
    Sculco, TP
    JOURNAL OF ARTHROPLASTY, 1995, 10 (06): : 855 - 859
  • [50] Third generation delta ceramic-on-ceramic bearing for total hip arthroplasty at mid-term follow-up
    Bistolfi, Alessandro
    Ferracini, Riccardo
    Aprato, Alessandro
    Masse, Alessandro
    Daghino, Walter
    Lea, Sara
    Artiaco, Stefano
    Lee, Gwo-Chin
    JOURNAL OF ORTHOPAEDICS, 2020, 22 : 397 - 401