Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials

被引:40
|
作者
Hu, Dongcai [1 ]
Tie, Kai [1 ]
Yang, Xiao [2 ]
Tan, Yang [1 ]
Alaidaros, Mohammed [1 ]
Chen, Liaobin [1 ]
机构
[1] Wuhan Univ, Dept Orthopaed Surg, Zhongnan Hosp, Wuhan 430071, Hubei, Peoples R China
[2] Wuhan Univ, Dept Intens Care Unit, Zhongnan Hosp, Wuhan 430071, Hubei, Peoples R China
关键词
Total hip arthroplasty; Bearing surface; Ceramic-on-ceramic; Metal-on-polyethylene; Meta-analysis; CONVENTIONAL POLYETHYLENE; PEDRO SCALE; ALUMINA; SQUEAKING; DISLOCATION; OSTEOLYSIS; QUALITY; WEAR; THA;
D O I
10.1186/s13018-015-0163-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: In recent years, the choice of ceramic-on-ceramic (COC) and metal-on-polyethylene (MOP) in primary total hip arthroplasty (THA) remains controversial. The purpose of this study was to compare the reliability and durability of COC with that of MOP bearing surfaces in THA. Methods: Based on prospective randomized controlled trials (RCTs) searched from Pubmed, Embase, Web of Science, and Cochrane central database, we performed a meta-analysis for comparing clinical and radiographic outcomes of COC with those of MOP. Two investigators independently selected studies, extracted data, and assessed risk of bias. Relative risks and weighted mean differences from each trial were pooled using random-effect or fixed-effect models depending on the heterogeneity of the included studies. Results: Five RCTs involving 897 patients with 974 hips met predetermined inclusion criteria. Our results demonstrated COC significantly decreased the risks of revision, osteolysis and radiolucent line, aseptic loosening, and dislocation and increased the risks of squeaking and intraoperative implant fracture compared with MOP. There was no significant difference between the two groups in postoperative hip function, deep infection, and heterotopic ossification. Conclusions: Generally, despite more squeaking and intraoperative implant fracture, our findings support the use of COC bearing surface which has lower rates of revision, osteolysis and radiolucent line, aseptic loosening, and dislocation compared with MOP.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials
    Dongcai Hu
    Kai Tie
    Xiao Yang
    Yang Tan
    Mohammed Alaidaros
    Liaobin Chen
    Journal of Orthopaedic Surgery and Research, 10
  • [2] Comparison of Ceramic-on-Ceramic vs. Ceramic-on-Polyethylene for Primary Total Hip Arthroplasty: A Meta-Analysis of 15 Randomized Trials
    Shang, Xiaobin
    Fang, Yan
    FRONTIERS IN SURGERY, 2021, 8
  • [3] Ceramic-on-Ceramic Versus Ceramic-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty
    Hu, Dongcai
    Yang, Xiao
    Tan, Yang
    Alaidaros, Mohammed
    Chen, Liaobin
    ORTHOPEDICS, 2015, 38 (04) : E331 - E338
  • [4] Is a ceramic-on-ceramic bearing really superior to ceramic-on-polyethylene for primary total hip arthroplasty? A systematic review and meta-analysis of randomised controlled trials
    Si, Hai-bo
    Zeng, Yi
    Cao, Fei
    Pei, Fu-xing
    Shen, Bin
    HIP INTERNATIONAL, 2015, 25 (03) : 191 - 198
  • [5] A Randomized Trial Comparing Ceramic-on-Ceramic Bearing vs Ceramic-on-Crossfire-Polyethylene Bearing Surfaces in Total Hip Arthroplasty
    Beaupre, Lauren A.
    Al-Houkail, Amro
    Johnston, Donald William C.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (06): : 1240 - 1245
  • [6] Comparison of Ceramic-on-Ceramic and Ceramic-on-Highly-Crosslinked-Polyethylene in Primary Total Hip Arthroplasty: Findings of a Meta-Analysis
    Almaawi, Abdulaziz
    Alzuhair, Abduljabbar
    AlHakbani, Abdulaziz
    Benfaris, Demah
    Al-Abdullatif, Fahad
    Alabdulkarim, Nouf H.
    Awwad, Waleed
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (02)
  • [7] Noise characteristics in ceramic-on-ceramic vs. metal-on-polyethylene total hip arthroplasty: a comparative study
    Robinson, Patrick G.
    Anthony, Ian
    Kumar, Sudeep
    Jones, Bryn
    Stark, Andrew
    Ingram, Roland
    HIP INTERNATIONAL, 2016, 26 (05) : 492 - 497
  • [8] Corrigendum: Comparison of Ceramic-on-Ceramic vs. Ceramic-on-Polyethylene for Primary Total Hip Arthroplasty: A Meta-Analysis of 15 Randomized Trials (vol 9, 876080, 2022)
    Fang, Yan
    Shang, Xiaobin
    FRONTIERS IN SURGERY, 2022, 9
  • [9] Squeaking sound in total hip arthroplasty using ceramic-on-ceramic bearing surfaces
    Ki, Sung-Chan
    Kim, Byung-Hak
    Ryu, Ji-Hoon
    Yoon, Dae-Hyun
    Chung, Young-Yool
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (01) : 21 - 25
  • [10] Bearing Change to Metal-On-Polyethylene for Ceramic Bearing Fracture in Total Hip Arthroplasty; Does It Work?
    Lee, Soong Joon
    Kwak, Hong Suk
    Yoo, Jeong Joon
    Kim, Hee Joong
    JOURNAL OF ARTHROPLASTY, 2016, 31 (01): : 204 - 208