Comparison of HIV-1 RNA Measurements Obtained by Using Plasma and Dried Blood Spots in the Automated Abbott Real-Time Viral Load Assay

被引:35
|
作者
Arredondo, Miguel [1 ]
Garrido, Carolina [1 ]
Parkin, Neil [2 ,3 ]
Zahonero, Natalia [1 ]
Bertagnolio, Silvia [2 ]
Soriano, Vincent [1 ]
de Mendoza, Carmen [1 ]
机构
[1] Hosp Carlos III, Dept Infect Dis, Madrid, Spain
[2] World Hlth Org, HIV Dept, Geneva, Switzerland
[3] Data First Consulting Inc, Menlo Pk, CA USA
关键词
DRUG-RESISTANCE SURVEILLANCE; DIFFERENT STORAGE-CONDITIONS; QUANTITATIVE ASSAYS; WHOLE-BLOOD; SPECIMENS; QUANTIFICATION; DIAGNOSIS; CAMEROON;
D O I
10.1128/JCM.00418-11
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Dried blood spots (DBS) may be a promising alternative specimen type to plasma for measuring the viral load (VL) in HIV-infected individuals in resource-limited settings. However, characterization of assay performance using DBS is incomplete. In this prospective study, the VL was measured in parallel using plasma and DBS specimens collected at the same time from 157 HIV-1-infected individuals. DBS were prepared by dispensing 50 mu l of blood onto filter paper cards and were stored desiccated at -20 degrees C. Nucleic acid extraction from plasma and DBS was performed automatically using the Abbott m2000sp instrument, and the VL was measured using the RealTime HIV-1 VL assay, which has a lower limit of detection of 40 HIV RNA copies/ml. The correlation between plasma and DBS results was good (R = 0.91; P < 0.001). The mean difference in the VL (DBS minus plasma) was 0.35 log copies (standard deviation [SD], 0.47 log copies). A total of 40 (26%) paired specimens had a difference of >0.5 log copy, and in 12 (7.8%) it was >1 log copy. the VL from DBS was measurable in 95.7% of specimens with a plasma VL of >2.74 log copies (550 HIV RNA copies/ml). In summary, the VL can reliably be measured using DBS with the Abbott RealTime HIV-1 assay. The estimated lower limit of detection of this automated methodology on DBS is 550 copies/ml, a threshold that may be acceptable for periodic VL monitoring in patients on antiretroviral therapy in resource-limited settings, where early detection of virologic treatment failure is often problematic.
引用
收藏
页码:569 / 572
页数:4
相关论文
共 50 条
  • [1] Measurement of viral load by the automated Abbott real-time HIV-1 assay using dried blood spots collected and processed in Malawi and Mozambique
    Erba, F.
    Brambilla, D.
    Ceffa, S.
    Ciccacci, F.
    Luhanga, R.
    Sidumo, Z.
    Palombi, L.
    Mancinelli, S.
    Marazzi, M. C.
    Andreotti, M.
    Giuliano, M.
    SAMJ SOUTH AFRICAN MEDICAL JOURNAL, 2015, 105 (12): : 1036 - 1038
  • [2] Comparison of the performance of Aptima HIV-1 Quant Dx Assay with Abbott RealTime HIV Assay for viral load monitoring using plasma and Dried Blood Spots collected in Kenya
    Mwau, Matilu
    Schaffer, Sven
    Kimani, Humphrey
    Kasiano, Purity
    Ogolla, Francis
    Ajema, Elizabeth
    Adoyo, Scriven
    Nyairo, Ednah
    Saleri, Norah
    Nair, Sangeetha Vijaysri
    PLOS ONE, 2022, 17 (08):
  • [3] Measure of Viral Load by Using the Abbott Real-Time HIV-1 Assay on Dried Blood and Plasma Spot Specimens Collected in 2 Rural Dispensaries in Cameroon
    Mbida, Andre Dieudonne
    Sosso, Samuel
    Flori, Pierre
    Saoudin, Henia
    Lawrence, Philip
    Monny-Lobe, Marcel
    Oyono, Yves
    Ndzi, Edward
    Cappelli, Giulia
    Lucht, Frederic
    Pozzetto, Bruno
    Oukem-Boyer, Odile Ouwe Missi
    Bourlet, Thomas
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2009, 52 (01) : 9 - 16
  • [4] Quantitation of HIV-1 RNA in dried blood spots by the real-time NucliSENS EasyQ HIV-1 assay in Senegal
    Kane, Coumba Toure
    Ndiaye, Halimatou Diop
    Diallo, Sada
    Ndiaye, Ibrahima
    Wade, Abdoulaye Sidibe
    Diaw, Papa Alassane
    Gaye-Diallo, Aissatou
    Mboup, Souleymane
    JOURNAL OF VIROLOGICAL METHODS, 2008, 148 (1-2) : 291 - 295
  • [5] Use of dried blood spots with Abbott RealTime HIV-1 quantitative RNA assay
    Huang, S.
    Erickson, B.
    Abravaya, K.
    Robinson, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2007, 9 (05): : 700 - 700
  • [6] Correlation between HIV-1 viral load quantification in plasma, dried blood spots, and dried plasma spots using the Roche COBAS Taqman assay
    Andreotti, Mauro
    Pirillo, Maria
    Guidotti, Giovanni
    Ceffa, Susanna
    Paturzo, Giovanna
    Germano, Paola
    Luhanga, Richard
    Chimwaza, David
    Mancini, Maria Grazia
    Marazzi, Maria Cristina
    Vella, Stefano
    Palombi, Leonardo
    Giuliano, Marina
    JOURNAL OF CLINICAL VIROLOGY, 2010, 47 (01) : 4 - 7
  • [7] Dried blood spots versus plasma for the quantitation of HIV-1 RNA using a real-Time PCR, m2000rt assay
    Vidya, Madhavan
    Saravanan, Shanmugam
    Rifkin, Samara
    Solomon, Sunil S.
    Waldrop, Greer
    Mayer, Kenneth H.
    Solomon, Suniti
    Balakrishnan, Pachamuthu
    JOURNAL OF VIROLOGICAL METHODS, 2012, 181 (02) : 177 - 181
  • [8] Evaluation of the Abbott Real-Time HIV-1 quantitative assay with dried blood spot specimens
    Marconi, A.
    Balestrieri, M.
    Comastri, G.
    Pulvirenti, F. R.
    Gennari, W.
    Tagliazucchi, S.
    Pecorari, M.
    Borghi, V.
    Marri, D.
    Zazzi, M.
    CLINICAL MICROBIOLOGY AND INFECTION, 2009, 15 (01) : 93 - 97
  • [9] Correlation between Human Immunodeficiency Virus Type 1 (HIV-1) RNA Measurements Obtained with Dried Blood Spots and Those Obtained with Plasma by Use of Nuclisens EasyQ HIV-1 and Abbott RealTime HIV Load Tests
    Garrido, Carolina
    Zahonero, Natalia
    Corral, Angelica
    Arredondo, Miguel
    Soriano, Vincent
    de Mendoza, Carmen
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (04) : 1031 - 1036
  • [10] Performance of the Abbott Realtime HIV-1: An automated assay for quantification of HIV-1 viral load in plasma.
    Abravaya, K
    Tang, N
    Huang, S
    Cloherty, G
    Mak, W
    Salituro, J
    Robinson, J
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2005, 7 (05): : 670 - 670