Method of Determining Pyrrole Imidazole Polyamide in Rat Plasma Using Ultra-Fast Liquid Chromatography-Ultraviolet Spectrometry

被引:0
|
作者
Miyamoto, Aoi [1 ]
Yagishita, Kouta [1 ]
Aoyama, Takahiko [1 ]
Abe, Masanori [2 ]
Fukuda, Noboru [2 ,3 ]
Matsumoto, Yoshiaki [1 ]
机构
[1] Nihon Univ, Sch Pharm, Lab Clin Pharmacokinet, 7-7-1 Narashinodai, Funabashi, Chiba 2748555, Japan
[2] Nihon Univ, Sch Med, Dept Internal Med, Div Nephrol Hypertens & Endocrinol, Tokyo 1738610, Japan
[3] Nihon Univ, Res Ctr, Tokyo 1028275, Japan
关键词
pyrrole-imidazole polyamide; ultra-fast LC; drug-discovery research; DNA; RECOGNITION;
D O I
10.1248/bpb.b19-00644
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
To improve the efficiency of drug-discovery research on pyrrole imidazole polyamides (PIs), a more rapid method for quantitative and qualitative measurement of PI in rat plasma samples was developed here using ultra-fast liquid chromatography-ultraviolet spectrometry (UFLC-UV) in order to shorten the measurement time. A measurement method of PIs by HPLC developed until now takes 45 min for one sample measurement. This method was inefficient to investigate extraction conditions from biological samples and measurement of animal experimental samples. In the developed method of this study, PI and phenacetin (internal standard, IS) were separated with an ACQUITY UPLC HSS T3 (1.8 mu m, 2.1 X 50 mm; Nihon Waters K.K., Japan) column using a mobile phase of 0.1% acetic acid (mobile phase A) and acetonitrile (mobile phase B) at a flow rate of 0.3 mL/min with a linear gradient. The detection wavelength was 310 nm. The calibration curve was linear in the range of 0.225-4.5 mu g/mL (correlation coefficients >= 0.9995, n = 5). The intra- and inter-day accuracies were in the range of -6.04 to 12.2%, and the precision was less than 2.99%. The measurement time of this method (7 min per injection) was markedly shortened to about one-sixth of the previous measurement time (45 min per injection). This is the first report describing the quantitative and qualitative measurement of PI in plasma using UFLC-UV. The present method will be very useful for the drug-discovery research of Pls.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 50 条
  • [41] Ultra fast liquid chromatography/tandem mass spectrometry for simultaneous quantification of ten phytoestrogens in plasma
    Prasain, J. K.
    Arabshahi, A.
    Moore, R.
    Peng, N.
    Wyss, J. M.
    Barnes, S.
    PLANTA MEDICA, 2008, 74 (03) : 362 - 362
  • [42] An improved ultra-high performance liquid chromatography-tandem mass spectrometry method determining hispidulin and homoplantaginin in rat plasma and associated pharmacokinetic studies
    Zhang, En
    Chen, Junying
    Li, Xia
    Luo, Lvqi
    Ma, Yizhe
    Zhang, Qingwei
    Wang, Xianqin
    ACTA CHROMATOGRAPHICA, 2023, 35 (04) : 331 - 337
  • [43] Ultra-high performance liquid chromatography with ultraviolet and tandem mass spectrometry for simultaneous determination of metabolites in purine pathway of rat plasma
    Lu, Jin-Jin
    Jia, Bing-Jie
    Yang, Lin
    Zhang, Wen
    Dong, Xin
    Li, Ping
    Chen, Jun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1036 : 84 - 92
  • [44] Ultra-fast tandem mass spectrometry scanning combined with monolithic column liquid chromatography increases throughput in proteomic analysis
    Batycka, Mariola
    Ingis, Neil F.
    Cook, Ken
    Adam, Alex
    Fraser-Pitt, Douglas
    Smith, David G. E.
    Main, Laura
    Lubben, Anneke
    Kessler, Benedikt M.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (14) : 2074 - 2080
  • [45] Development of a sensitive method for determining traces of prohibited acrylamide in cosmetic products based on dispersive liquid-liquid microextraction followed by liquid chromatography-ultraviolet detection
    Schettino, Lorenza
    Benede, Juan L.
    Chisvert, Alberto
    Salvador, Amparo
    MICROCHEMICAL JOURNAL, 2020, 159
  • [46] ESTABLISHMENT OF SOLID-PHASE EXTRACTION METHOD FOR THE RECOVERY OF PYRROLE-IMIDAZOLE POLYAMIDES FROM RAT URINE USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY SYSTEM WITH ULTRAVIOLET DETECTOR
    Nagashima, Takashi
    Fukasawa, Akiko
    Aoyama, Takahiko
    Fukuda, Noboru
    Matsuda, Hiroyuki
    Ueno, Takahiro
    Sugiyama, Hiroshi
    Nagase, Hiroki
    Matsumoto, Yoshiaki
    DRUG METABOLISM REVIEWS, 2007, 39 : 57 - 57
  • [47] Simultaneous detection and quantification of 57 compounds in Spatholobi Caulis applying ultra-fast liquid chromatography with tandem mass spectrometry
    Liu, Xiao-Yan
    Zhang, Lei
    Yang, Xiu-Wei
    Zhang, You-Bo
    Xu, Wei
    Zhang, Peng
    Zhao, Wei
    Peng, Kai-Feng
    Gong, Yun
    Liu, Ni-Fu
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (23) : 4247 - 4262
  • [48] Ultra-fast screening of free fatty acids in human plasma using ion mobility mass spectrometry
    Wang, Yinghao
    Zhang, Xianxie
    Hu, Wenya
    Dong, Chenglong
    Fu, Dali
    Habtegabir, Sara Girmay
    Han, Yehua
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (10) : 1818 - 1826
  • [49] Combination of a liquid chromatography-ultraviolet method with a non-volatile eluent, peak trapping and a liquid chromatography-mass spectrometry method with a volatile eluent to characterise erythromycin related substances
    Pendela, Murali
    Van den Bossche, Larissa
    Hoogmartens, Jos
    Van Schepdael, Ann
    Adams, Erwin
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1180 (1-2) : 108 - 121
  • [50] Determination of imatinib plasma levels in patients with chronic myeloid leukemia by high performance liquid chromatography-ultraviolet detection and liquid chromatography-tandem mass spectrometry: Methods' comparison
    Awidi, Abdalla
    Salem, Isam I.
    Najib, Naji
    Mefleh, Razan
    Tarawneh, Bothainah
    LEUKEMIA RESEARCH, 2010, 34 (06) : 714 - 717