Method of Determining Pyrrole Imidazole Polyamide in Rat Plasma Using Ultra-Fast Liquid Chromatography-Ultraviolet Spectrometry

被引:0
|
作者
Miyamoto, Aoi [1 ]
Yagishita, Kouta [1 ]
Aoyama, Takahiko [1 ]
Abe, Masanori [2 ]
Fukuda, Noboru [2 ,3 ]
Matsumoto, Yoshiaki [1 ]
机构
[1] Nihon Univ, Sch Pharm, Lab Clin Pharmacokinet, 7-7-1 Narashinodai, Funabashi, Chiba 2748555, Japan
[2] Nihon Univ, Sch Med, Dept Internal Med, Div Nephrol Hypertens & Endocrinol, Tokyo 1738610, Japan
[3] Nihon Univ, Res Ctr, Tokyo 1028275, Japan
关键词
pyrrole-imidazole polyamide; ultra-fast LC; drug-discovery research; DNA; RECOGNITION;
D O I
10.1248/bpb.b19-00644
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
To improve the efficiency of drug-discovery research on pyrrole imidazole polyamides (PIs), a more rapid method for quantitative and qualitative measurement of PI in rat plasma samples was developed here using ultra-fast liquid chromatography-ultraviolet spectrometry (UFLC-UV) in order to shorten the measurement time. A measurement method of PIs by HPLC developed until now takes 45 min for one sample measurement. This method was inefficient to investigate extraction conditions from biological samples and measurement of animal experimental samples. In the developed method of this study, PI and phenacetin (internal standard, IS) were separated with an ACQUITY UPLC HSS T3 (1.8 mu m, 2.1 X 50 mm; Nihon Waters K.K., Japan) column using a mobile phase of 0.1% acetic acid (mobile phase A) and acetonitrile (mobile phase B) at a flow rate of 0.3 mL/min with a linear gradient. The detection wavelength was 310 nm. The calibration curve was linear in the range of 0.225-4.5 mu g/mL (correlation coefficients >= 0.9995, n = 5). The intra- and inter-day accuracies were in the range of -6.04 to 12.2%, and the precision was less than 2.99%. The measurement time of this method (7 min per injection) was markedly shortened to about one-sixth of the previous measurement time (45 min per injection). This is the first report describing the quantitative and qualitative measurement of PI in plasma using UFLC-UV. The present method will be very useful for the drug-discovery research of Pls.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 50 条
  • [31] Analysis of omarigliptin forced degradation products by ultra-fast liquid chromatography, mass spectrometry, and in vitro toxicity assay
    Mohr, Amanda
    Barbosa, Fabio de Souza
    Wingert, Nathalie Ribeiro
    Takeuchi, Carolina Kisara
    Garcia, Luiza
    Ribeiro, Maria Fernanda Nunes
    Arbo, Marcelo Dutra
    de Oliveira, Tiago Franco
    Steppe, Martin
    BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (08)
  • [32] Chemical profiling of Banxia-Baizhu-Tianma decoction by ultra-fast liquid chromatography with tandem mass spectrometry
    Fu, Yuanyuan
    Shan, Mingqiu
    Hu, Minhui
    Jiang, Yulan
    Chen, Peidong
    Chi, Yumei
    Yu, Sheng
    Zhang, Li
    Wu, Qinan
    Zhang, Facheng
    Mao, Zhiying
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 174 : 595 - 607
  • [33] Chemical profiling and multicomponents quantitative analysis of Panzerina lanata by ultra-fast liquid chromatography with tandem mass spectrometry
    Mi, Yingying
    Zheng, Wei
    Zhao, Xiangpei
    Zhang, Xun
    Yang, Kang
    Shen, Gangyi
    Liu, Weizhi
    Li, Wenrui
    Ma, Baiping
    Zhu, Dan
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (13) : 2524 - 2535
  • [34] Qualitative and Quantitative Analysis of the Saponins in Panacis Japonici Rhizoma Using Ultra-Fast Liquid Chromatography Coupled with Triple Quadrupole-Time of Flight Tandem Mass Spectrometry and Ultra-Fast Liquid Chromatography Coupled with Triple Quadrupole-Linear Ion Trap Tandem Mass Spectrometry
    Chen, Jiali
    Tan, Mengxia
    Zou, Lisi
    Liu, Xunhong
    Chen, Shuyu
    Shi, Jingjing
    Chen, Cuihua
    Wang, Chengcheng
    Mei, Yuqi
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2019, 67 (08) : 839 - 848
  • [35] Pharmacokinetics and tissue distribution study of schisandrin B in rats by ultra-fast liquid chromatography with tandem mass spectrometry
    Zhu, Heyun
    Zhang, Xiurong
    Guan, Jiao
    Cui, Baiji
    Zhao, Longshan
    Zhao, Xu
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 78-79 : 136 - 140
  • [36] Study on pharmacokinetics of 3,4-divanillyltetrahydrofuran in rats by ultra-fast liquid chromatography/tandem mass spectrometry
    Shan, Chen-xiao
    Cui, Xiao-bing
    Yu, Sheng
    Chai, Chuan
    Wen, Hong-mei
    Wang, Xin-zhi
    Sun, Xue
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1008 : 250 - 254
  • [37] Determination of cefuroxime lysine in rat brain microdialysates by ultra-fast liquid chromatography with UV and tandem mass spectrometry: application to an acute toxicokinetic study
    Zhao, Longshan
    Li, Qing
    Zhu, Heyun
    Chen, Xiaohui
    Bi, Kaishun
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (09) : 1199 - 1204
  • [38] High-throughput determination of barbiturates in human plasma using on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry
    Lee, Xiao-Pen
    Kumazawa, Takeshi
    Hasegawa, Chika
    Arinobu, Tetsuya
    Seno, Hiroshi
    Suzuki, Osamu
    Sato, Keizo
    FORENSIC TOXICOLOGY, 2013, 31 (01) : 9 - 20
  • [39] Determination of Linezolid in Rat Plasma by Ultra Performance Liquid Chromatography Tandem Mass Spectrometry
    Zhang, Lin
    Zheng, Yi
    Wang, Xiaodong
    Zhou, Changsheng
    Jin, Lingxiang
    Pan, Zhenzhen
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 : 1130 - 1135
  • [40] Ultra Performance Liquid Chromatography Tandem Mass Spectrometry Determination of Ibrutinib in Rat Plasma
    Chen, Xiaole
    Wang, Chunjie
    Chen, Minle
    Zhou, Quan
    Liu, Zezheng
    Zhang, Jing
    Zhou, Shihong
    Wen, Congcong
    Zhang, Meiling
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (01): : 38 - 43