Transcatheter occlusion of the patent ductus arteriosus with a single device technique: comparison between the Cook detachable coil and the Rashkind umbrella device

被引:6
|
作者
Jaeggi, ET
Fasnacht, M
Arbenz, U
Beghetti, M
Bauersfeld, U
Friedli, B
机构
[1] Univ Geneva, Childrens Hosp, CH-1211 Geneva, Switzerland
[2] Univ Zurich, Childrens Hosp, CH-8032 Zurich, Switzerland
关键词
patent ductus arteriosus; transcatheter occlusion; Rashkind device; coil;
D O I
10.1016/S0167-5273(01)00406-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter coil occlusion of the patent ductus arteriosus (PDA) has become the interventional treatment option of choice. Immediate occlusion of any residual shunting results in excellent closure rates, but frequently requires multiple coil deployment. Aims: To assess the efficacy and limitations of single Cook detachable coil PDA closure compared to a preceding series of Rashkind umbrella procedures. Methods and results: Between 1990 and 1999. transcatheter occlusion of a small (<2 mm: n=45) or moderate-sized (2-4 mm: n=47) PDA was successfully attempted in 90/92 consecutive patients (mean ape 6 +/-4.8 years) with a coil (39/41) or Rashkind device (51/51). Immediate angiographic closure rates for both devices were low. although better for small (54-68%) than moderate ducts (7-22%. P <0.01). A 2-year echocardiographic closure rate of small ducts increased to 92% fur the coil group versus 95% for the Rashkind group. By that rims, moderate-sized ducts were only occluded in 64% with the coil and 54% with the Rashkind device. A visible residual shunt at post-implant angiography in moderate ducts was associated with a high incidence (59%) of long-term echocardiographic shunt patency and a need for repeat intervention for audible residual shunts (32%). Conclusions: Single coil transcatheter occlusion is the treatment of choice for the small duct as most residual shunts will resolve spontaneously. However, long-term shunt persistence after single coil deployment in moderate sized ducts is as frequent as with the Rashkind device. A primary multiple coil approach is advocated if the postcoil aortogram shows residual ductal shunting and if there is persistence of a ductal murmur on auscultation. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [41] Evolution of a Novel Intraductal Patent Ductus Arteriosus Occlusion Device
    Agrawal, Megha
    Sonetha, Vaibhavi A.
    Sharma, Smriti
    Parakh, Satyajeet
    Dalvi, Bharat
    Bellare, Jayesh R.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2011, 5 (03):
  • [42] Transcatheter closure of very large patent ductus arteriosus with the modified patent ductus arteriosus closure device.
    Zhang, F.
    Ge, J.
    Zhou, D.
    Guan, L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 50D - 50D
  • [43] Echocardiographic guidance for transcatheter coil occlusion of patent ductus arteriosus in the catheterization laboratory
    Liang, CD
    Ko, SF
    Huang, SC
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (05) : 476 - 479
  • [44] Transcatheter occlusion of a patent ductus arteriosus in a Newfoundland puppy using the Gianturco-Grifka vascular occlusion device
    Grifka, RG
    Miller, MW
    Frischmeyer, KJ
    Mullins, CE
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 1996, 10 (01) : 42 - 44
  • [45] Transcatheter coil occlusion of patent ductus arteriosus and follow-up results
    Atik, Sezen Ugan
    Saltik, Irfan Levant
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2019, 47 (04): : 265 - 272
  • [46] New forceps delivery technique for coil occlusion of patent ductus arteriosus
    Hays, MD
    Hoyer, MH
    Glasow, PF
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (02): : 209 - 211
  • [47] Transjugular patent ductus arteriosus occlusion in a cat with a peripheral vascular occlusion device
    Lynn, C. R.
    Samper, I. S.
    Walsh, M.
    Babineau, S.
    Brisson, J. O.
    JOURNAL OF VETERINARY CARDIOLOGY, 2021, 38 : 31 - 35
  • [48] Transcatheter patent ductus arteriosus closure in an infant using the Gianturco-Grifka Vascular Occlusion Device
    Grifka, RG
    Vincent, JA
    Nihill, MR
    Ing, FF
    Mullins, CE
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (06): : 721 - 723
  • [49] TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS WITH ADJUSTABLE BUTTONED DEVICE - INITIAL CLINICAL-EXPERIENCE
    RAO, PS
    SIDERIS, EB
    HADDAD, J
    REY, C
    HAUSDORF, G
    WILSON, AD
    SMITH, PA
    CHOPRA, PS
    CIRCULATION, 1993, 88 (03) : 1119 - 1126
  • [50] Transcatheter closure of a patent ductus arteriosus in an elderly patient with the Gianturco-Grifka vascular occlusion device
    Befeler, B
    Justiniano, A
    Zahn, E
    CLINICAL CARDIOLOGY, 2000, 23 (10) : 790 - 791