Transcatheter coil occlusion of patent ductus arteriosus and follow-up results

被引:1
|
作者
Atik, Sezen Ugan [1 ]
Saltik, Irfan Levant [1 ]
机构
[1] Istanbul Univ Cerrahpasa, Cerrahpasa Tip Fak, Cocuk Kardiyol Bil Dali, Istanbul, Turkey
来源
TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY | 2019年 / 47卷 / 04期
关键词
Child; coil; patent ductus arteriosus; transcatheter occlusion; CARDIAC-CATHETERIZATION; PERCUTANEOUS CLOSURE; STATEMENT; HEMOLYSIS; LIGATION; OCCLUDER; MODERATE; DISEASE; YOUNG;
D O I
10.5543/tkda.2019.35405
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Although many articles have been published about transcatheter coil occlusion, few studies have been conducted on the long-term outcomes of patent ductus arteriosus closure with a coil. This study is an examination of the follow-up data of patients who underwent transcatheter patent ductus arteriosus closure with a coil. Methods: Between May 1996 and May 2018, 243 patients underwent transcatheter patent ductus arteriosus closure with a coil. The patients were divided into 2 groups based on the timing of the use of ductal occluders at the facility. Until the end of 2005, every ductus was closed with a coil. Since initiating the use of ductal occluders in 2006, coils are mostly used to close small, elongated ducts, and occasionally, some complex ducts. Results: The median age of the patient was 4.33 years, the median weight was 15 kg, and the median duct diameter was 2 mm. In this study group, 98 (40%) patients were male and 145 were female (60%). The angiographic features of the ductus were classified as type A in 126 patients, type B in 15, type C in 6, type D in 9, type E in 74, and 13 were recorded as other types. In 238 of the patients, the patent ductus arteriosus was successfully closed with a coil. In 5 (2.2%) cases, the procedure was unsuccessful. Echocardiography follow-up continued for an average of 4.1 +/- 4.1 years (1 day-19 years). A residual shunt was observed in 42 patients, and spontaneous occlusion was seen in 29 of the 42 patients. Conclusion: The results of this study indicated that closure of the patent ductus arteriosus with a coil was a safe and effective method.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 50 条
  • [1] Follow-up of coil occlusion of patent ductus arteriosus
    Shim, D
    Fedderly, RT
    Beekman, RH
    Ludomirsky, A
    Young, ML
    Schork, MA
    Lloyd, TR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (01) : 207 - 211
  • [2] Follow-Up Results of Device Occlusion of Patent Ductus Arteriosus
    Amoozgar, Hamid
    Salehi, Sara
    Farhadi, Pouya
    Edraki, Mohammad Reza
    Borzoee, Mohammad
    Ajami, Gholamhossein
    Cheriki, Sirous
    Mohammadi, Hamid
    IRANIAN JOURNAL OF PEDIATRICS, 2016, 26 (03)
  • [3] TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS BY RASHKIND UMBRELLA DEVICE - FOLLOW-UP RESULTS
    ARORA, R
    KALRA, GS
    NIGAM, M
    KHALILLULAH, M
    AMERICAN HEART JOURNAL, 1994, 128 (03) : 539 - 541
  • [4] TRANSCATHETER COIL OCCLUSION OF PATENT DUCTUS-ARTERIOSUS
    FEDDERLY, RT
    LLOYD, TR
    MENDELSOHN, AM
    SANDHU, SK
    LUDOMIRSKY, A
    BEEKMAN, RH
    CIRCULATION, 1993, 88 (04) : 389 - 389
  • [5] Follow-up results of transvenous occlusion of patent ductus arteriosus with the buttoned device
    Rao, PS
    Kim, SH
    Choi, JY
    Rey, C
    Haddad, J
    Marcon, F
    Walsh, K
    Sideris, EB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (03) : 820 - 826
  • [6] Follow-up after coil closure of patent ductus arteriosus
    Goyal, VS
    Fulwani, MC
    Ramakantan, R
    Kulkarni, HL
    Dalvi, BV
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (03): : 463 - +
  • [7] Transcatheter occlusion of patent ductus arteriosus using coil embolization
    Jacob, JLB
    Coelho, MWC
    Machado, NCS
    Garzon, SAC
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1997, 60 (02) : 133 - 138
  • [8] Transvenous occlusion of patent ductus arteriosus with buttoned device in adults: Follow-up results
    SyamasundarRao, P
    Ho, KS
    Rey, C
    Onorato, E
    Sideris, EB
    CIRCULATION, 1997, 96 (08) : 1201 - 1201
  • [9] Five-loop coil occlusion of patent ductus arteriosus prevents recurrence of shunt at follow-up
    Rao, PS
    Balfour, IC
    Jureidini, SB
    Singh, GK
    Chen, SC
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 50 (02) : 202 - 206
  • [10] Lung perfusion scintigraphic follow-up results of coil embolization for patent ductus arteriosus.
    Sato, S
    Takeda, Y
    Okumura, Y
    Tamizu, A
    Kanazawa, S
    Hiraki, Y
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 344P - 344P