Three-dimensional ultrasound for carotid vessel wall volume measurement

被引:1
|
作者
Chen, Ying-An [1 ,2 ]
Chen, Pei-Ya [1 ,2 ,3 ]
Lin, Shinn-Kuang [1 ,2 ,3 ]
机构
[1] Taipei Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Stroke Ctr, 289 Jianguo Rd, New Taipei, Taiwan
[2] Taipei Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Dept Neurol, 289 Jianguo Rd, New Taipei, Taiwan
[3] Tzu Chi Univ, Sch Med, Hualien, Taiwan
来源
TZU CHI MEDICAL JOURNAL | 2022年 / 34卷 / 01期
关键词
Interobserver reliability; Intima-media thickness; Three-dimensional ultrasound; Total plaque volume; Vessel wall volume; INTIMA-MEDIA THICKNESS; CARDIOVASCULAR RISK; ARTERY-DISEASE; PLAQUE; REPRODUCIBILITY; ATHEROSCLEROSIS; STROKE;
D O I
10.4103/tcmj.tcmj_283_20
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The intima-media thickness (IMT) of the carotid artery can now be detected on a three-dimensional (3D) plane. The 3D vessel wall volume (VWV) more accurately represents vascular conditions. Through 3D ultrasound, we established a standardized method for carotid VWV measurement. Materials and Methods: A total of thirty patients without stroke or cardiovascular disease who received carotid duplex sonography were retrospectively reviewed. Gray-scale 3D images from the distal common carotid artery (CCA) to internal carotid artery on both sides were acquired using a single-sweep 3D transducer and analyzed offline by using the vascular plaque quantification function of the Philips QLAB software. Then, the 3D IMT(QLAB intima-media thickness [QIMT]), total plaque volume (TPV), and VWV were measured by a neurologist and a technician, and the interobserver variability was assessed. Results: The mean two-dimensional (2D) carotid IMT was 0.65 +/- 0.12 mm. The mean QIMT, TPV, and VWV measured by observer 1 were 0.68 +/- 0.18 mm, 26 +/- 12 mm3, and 94 +/- 10 mm3, respectively. The Bland-Altman plot of the mean differences between the QIMT, TPV, and VWV values measured by observers 1 and 2 showed that those of observer 2 were within two standard deviations of those of observer 1. Intraclass correlation coefficients (ICCs) indicated strong correlations in QIMT (ICC = 0.76), TPV (ICC = 0.85), and VWV (ICC = 0.90; P < 0.001) between observers 1 and 2. Both 2D IMT and 3D QIMT exhibited a positive linear correlation with age. Conclusion: This study established a standardized VWV measurement through 3D ultrasound. Reasonable interobserver differences were obtained within a 95% limit of agreement and high reliability (ICC = 0.90). The VWV 1 cm from the CCA bifurcation was quantified with a mean value of 94.2 mm3. Further studies on the 3D ultrasound quantification of carotid arteries are warranted.
引用
收藏
页码:88 / 94
页数:7
相关论文
共 50 条
  • [21] Measurement of subretinal fluid volume in serous retinal detachment with three-dimensional ultrasound
    Rosen, RB
    Iezzi, R
    Romero, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 5209 - 5209
  • [22] Reproducibility of fetal renal pelvis volume measurement using three-dimensional ultrasound
    Duin, L. K.
    Willekes, C.
    Vossen, M.
    Beckers, M.
    Offermans, J.
    Nijhuis, J. G.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (06) : 657 - 661
  • [23] In vitro volume measurement by three-dimensional ultrasound: comparison of two different systems
    Hosli, IM
    Tercanli, S
    Herman, A
    Kretschmann, M
    Holzgreve, W
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 11 (01) : 17 - 22
  • [24] Three-dimensional ultrasound imaging for the evaluation of carotid atherosclerosis
    Makris, Gregory C.
    Lavida, Anthi
    Griffin, Maura
    Geroulakos, George
    Nicolaides, Andrew N.
    ATHEROSCLEROSIS, 2011, 219 (02) : 377 - 383
  • [25] Prospective cardiac gating of carotid three-dimensional ultrasound
    Mallett, Christiane
    Gardi, Lori
    Fenster, Aaron
    Parraga, Grace
    MEDICAL PHYSICS, 2009, 36 (07) : 3168 - 3175
  • [26] Three-dimensional ultrasound measurements of carotid vessel wall and plaque thickness and their relationship with pulmonary abnormalities in ex-smokers without airflow limitation
    Jieyu Cheng
    Damien Pike
    Tommy W. S. Chow
    Miranda Kirby
    Grace Parraga
    Bernard Chiu
    The International Journal of Cardiovascular Imaging, 2016, 32 : 1391 - 1402
  • [27] Three-dimensional ultrasound measurements of carotid vessel wall and plaque thickness and their relationship with pulmonary abnormalities in ex-smokers without airflow limitation
    Cheng, Jieyu
    Pike, Damien
    Chow, Tommy W. S.
    Kirby, Miranda
    Parraga, Grace
    Chiu, Bernard
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (09): : 1391 - 1402
  • [28] Measurement of carotid plaque volume by 3-dimensional ultrasound
    Landry, A
    Spence, JD
    Fenster, A
    STROKE, 2004, 35 (04) : 864 - 869
  • [29] Three-dimensional ultrasound for the measurement of choroidal melanomas
    Romero, JM
    Finger, PT
    Rosen, RB
    Iezzi, R
    ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (09) : 1275 - 1282
  • [30] In vitro measurement accuracy of three-dimensional ultrasound
    Zotz, RJ
    Trabold, T
    Bock, A
    Kollmann, C
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (02): : 149 - 156