Three-dimensional ultrasound for the measurement of choroidal melanomas

被引:0
|
作者
Romero, JM
Finger, PT
Rosen, RB
Iezzi, R
机构
[1] New York Eye Canc Ctr, New York, NY 10021 USA
[2] New York Eye & Ear Infirm, New York, NY 10003 USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the reliability of 3-dimensional ultrasound (3D-US) for the measurement of choroidal melanomas. Design: Retrospective case series. Participants: Forty-two consecutive cases of choroidal melanoma imaged with 3D-US. Methods: Tumor measurements obtained with ophthalmoscopy, transillumination, standard ultrasound techniques, 3D-US, and pathological studies, Tumor diameters, heights, and volumes were compared. Our 3D-US tumor measurement techniques were tested for intraobserver and interscan reproducibility. Results: Fifty 3D-US images were studied. The 3D-US tumor measurements were found to be reproducible (height coefficient of variation [CV] less than or equal to3%; diameter CV less than or equal to9.7%; volume CV less than or equal to 13.2%). There was significant correlation with the usual methods of tumor measurement (diameter r=0.76; height r greater than or equal to0.98). Significant differences were found between measurements at pathological examination, as compared with both 2-dimensional and 3D-US height measurements (range, 0.73-0.83 mm). This finding was thought to be due to specimen shrinkage. Three-dimensional ultrasound was found to be at least as reproducible as clinical examination and standard ultrasound techniques used for measurement of diameter and height of choroidal melanomas. It was our impression that the 3D-US volume measurements accounted for the geometry of the tumor better than volume estimates calculated from basal area and tumor height. Conclusions: Three-dimensional ultrasound measurements of choroidal melanoma were reproducible, correlated well with other tumor measurement techniques, and can be used for measurement of choroidal melanomas.
引用
收藏
页码:1275 / 1282
页数:8
相关论文
共 50 条
  • [1] Three-dimensional ultrasonography of radioactive plaques in the treatment of choroidal melanomas
    Romero, JM
    Finger, PT
    Rosen, RB
    Iezzi, R
    Tello, CS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3330 - 3330
  • [2] Three-dimensional ultrasound of circumscribed choroidal hemangiomas.
    Castanheira, VRC
    Finger, PT
    Ponce-Contreras, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S334 - S334
  • [3] In vitro measurement accuracy of three-dimensional ultrasound
    Zotz, RJ
    Trabold, T
    Bock, A
    Kollmann, C
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (02): : 149 - 156
  • [4] Outcomes of medium choroidal melanomas treated with ruthenium brachytherapy guided by three-dimensional pretreatment modeling
    Browne, Andrew W.
    Dandapani, Savita V.
    Jennelle, Richard
    Stevanovic, Marta
    Lee, Thomas C.
    Murphree, A. Linn
    Kampp, Thomas D.
    Astrahan, Melvin A.
    Kim, Jonathan W.
    Berry, Jesse L.
    BRACHYTHERAPY, 2015, 14 (05) : 718 - 725
  • [5] Three-dimensional ultrasound for volume measurement of liver tumors
    Lang, H
    Wolf, GK
    Prokop, M
    Nuber, B
    Weimann, A
    Raab, R
    Zoller, WG
    CHIRURG, 1999, 70 (03): : 246 - 250
  • [6] Three-dimensional ultrasound
    Nelson, TR
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 51 - 52
  • [7] Three-dimensional ultrasound
    Kavic, MS
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1996, 10 (01): : 74 - 76
  • [8] Measurement of fetal nuchal translucency thickness by three-dimensional ultrasound
    Paul, C
    Krampl, E
    Skentou, C
    Jurkovic, D
    Nicolaides, KH
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 18 (05) : 481 - 484
  • [9] Sphenoidal fontanelle area measurement on rendered three-dimensional ultrasound
    Ioannou, Christos
    Sarris, Ippokratis
    Javaid, Muhammad K.
    Papageorghiou, Aris T.
    PRENATAL DIAGNOSIS, 2012, 32 (06) : 592 - 595
  • [10] Three-dimensional transvaginal ultrasound improves measurement of nuchal translucency
    Kurjak, A
    Kupesic, S
    Ivancic-Kosuta, M
    JOURNAL OF PERINATAL MEDICINE, 1999, 27 (02) : 97 - 102