Three-dimensional ultrasound for the measurement of choroidal melanomas

被引:0
|
作者
Romero, JM
Finger, PT
Rosen, RB
Iezzi, R
机构
[1] New York Eye Canc Ctr, New York, NY 10021 USA
[2] New York Eye & Ear Infirm, New York, NY 10003 USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the reliability of 3-dimensional ultrasound (3D-US) for the measurement of choroidal melanomas. Design: Retrospective case series. Participants: Forty-two consecutive cases of choroidal melanoma imaged with 3D-US. Methods: Tumor measurements obtained with ophthalmoscopy, transillumination, standard ultrasound techniques, 3D-US, and pathological studies, Tumor diameters, heights, and volumes were compared. Our 3D-US tumor measurement techniques were tested for intraobserver and interscan reproducibility. Results: Fifty 3D-US images were studied. The 3D-US tumor measurements were found to be reproducible (height coefficient of variation [CV] less than or equal to3%; diameter CV less than or equal to9.7%; volume CV less than or equal to 13.2%). There was significant correlation with the usual methods of tumor measurement (diameter r=0.76; height r greater than or equal to0.98). Significant differences were found between measurements at pathological examination, as compared with both 2-dimensional and 3D-US height measurements (range, 0.73-0.83 mm). This finding was thought to be due to specimen shrinkage. Three-dimensional ultrasound was found to be at least as reproducible as clinical examination and standard ultrasound techniques used for measurement of diameter and height of choroidal melanomas. It was our impression that the 3D-US volume measurements accounted for the geometry of the tumor better than volume estimates calculated from basal area and tumor height. Conclusions: Three-dimensional ultrasound measurements of choroidal melanoma were reproducible, correlated well with other tumor measurement techniques, and can be used for measurement of choroidal melanomas.
引用
收藏
页码:1275 / 1282
页数:8
相关论文
共 50 条
  • [31] Accuracy of three-dimensional ultrasound for thyroid volume measurement in children and adolescents
    Lyshchik, A
    Drozd, V
    Reiners, C
    THYROID, 2004, 14 (02) : 113 - 120
  • [32] Measurement and visualization of three-dimensional vertebra shape by freehand ultrasound scanning
    Kohyama, K
    Yasumuro, Y
    Imura, M
    Manabe, Y
    Oshiro, O
    Moroi, K
    Chihara, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (6B): : 4637 - 4641
  • [33] Serial fetal lung volume measurement using three-dimensional ultrasound
    Bahmaie, A
    Hughes, SW
    Clark, T
    Milner, A
    Saunders, J
    Tilling, K
    Maxwell, DJ
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (02) : 154 - 158
  • [34] Measurement of axial vertebral rotation using three-dimensional ultrasound images
    Vo, Quang N.
    Lou, Edmond H. M.
    Le, Lawrence H.
    SCOLIOSIS AND SPINAL DISORDERS, 2015, 10
  • [35] Three-dimensional ultrasound measurement of thyroid volume in asymptomatic male Chinese
    Ng, E
    Chen, T
    Lam, R
    Sin, DM
    Ying, M
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (11): : 1427 - 1433
  • [36] Three-dimensional versus two-dimensional ultrasound measurement of follicular volume: are they comparable?
    Ahmed Amer
    Mohamad Eid Hammadeh
    Mohamed Kolkailah
    Abdel-Al Ghandour
    Archives of Gynecology and Obstetrics, 2003, 268 (3) : 155 - 157
  • [37] Tumor Volumes in Choroidal Melanoma: Agreement Between Three-Dimensional Ultrasound and Two Mathematical Models
    Caminal, Josep M.
    Mejia, Karol
    Arias, Luis
    Masuet-Aumatell, Cristina
    Larrucea-Maseda, Jon
    Modolell, Ignasi
    Lorenzo, Daniel
    Catala, Jaume
    Rubio, Marc
    Cobos, Estefania
    Garcia-Bru, Pere
    Flores, Ignacio
    Filloy, Alejandro
    Arruga, Jordi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 166 : 181 - 188
  • [38] Measurement of three-dimensional permeability
    Weitzenbock, JR
    Shenoi, RA
    Wilson, PA
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 1998, 29 (1-2) : 159 - 169
  • [39] Three-dimensional volume measurement
    Schwartz, G
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 11 (01) : 4 - 5
  • [40] Three-dimensional measurement of ceramics
    不详
    POWDER METALLURGY, 1997, 40 (01) : 20 - 22