Development of a new HPLC method for rapid histamine quantification in fish and fishery products without sample clean-up

被引:11
|
作者
Kounnoun, Ayoub [1 ]
Louajri, Adnane [1 ]
Cacciola, Francesco [2 ]
El Baaboua, Aicha [1 ]
Mondello, Luigi [3 ,4 ,5 ]
Bougtaib, Hajar [1 ]
Alahlah, Naoual [6 ]
Stitou, Meriem [6 ]
El Maadoudi, Mohamed [6 ]
机构
[1] Abd Al Malek Essaadi Univ, Fac Sci Tetouan, Dept Biol, Lab Appl Biol & Pathol, Tetouan, Morocco
[2] Univ Messina, Dept Biomed Dent Morphol & Funct Imaging Sci, Messina, Italy
[3] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
[4] Univ Messina, Chromaleont Srl, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
[5] Univ Campus Biomed Rome, Dept Sci & Technol Human & Environm, Rome, Italy
[6] Natl Off Food Safety ONSSA, Reg Anal & Res Lab, Tangier, Morocco
关键词
Histamine; Fish; HPLC-FLD; Pre-column derivatization; Optimization; Validation; ORTHO-PHTHALALDEHYDE; LIQUID-CHROMATOGRAPHY; FLUORESCENCE REACTION; BIOGENIC-AMINES; DERIVATIZATION; DERIVATIVES; VALIDATION; STABILITY; FRESH; ACIDS;
D O I
10.1007/s00217-022-03995-z
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
HPLC methods are among the most studied and validated techniques for the quantification of histamine in fish and fishery products; nonetheless, most of these methods require laborious sample extraction and purification. For this purpose, in the present study, an HPLC-FLD method without any sample clean-up procedure was developed, validated and applied for histamine quantification in various fish samples. Histamine was extracted from fish and fishery products samples with perchloric acid; then a simple precolumn derivatization with o-phthalaldehyde was performed in the presence of the reducing agent 2-mercaptoethanol. Once the derivatization was carried out, the separation was performed with a reverse phase HPLC system. In terms of validation, good linearity and specificity over a concentration range from 12.5 to 200 mg/kg were achieved. Also, convenable precision with relative standard deviations smaller than 5.92%, accuracy ranged from 0.40 to 1.84%, and satisfactory recoveries ranged from 100.44 to 101.84%, were obtained. The detection and the quantification limits were calculated at 2.8 and 4.3 mg/kg, respectively. In addition, the effectiveness of the method was evaluated by the analysis of reference materials, proficiency tests and various type of samples. Moreover, the developed method was found to be simple, rapid, and reliable.
引用
收藏
页码:1679 / 1689
页数:11
相关论文
共 50 条
  • [41] Development of a vortex oscillating clean-up column for high-throughput semi-automatic sample preparation of drug residues in fish muscle tissues
    Zhou, Ruidong
    Mu, Shuhe
    Feng, Tengwang
    Liu, Huan
    Sun, Huiwu
    Li, Jincheng
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2022, 109
  • [42] Determination of triazine herbicides in seaweeds: Development of a sample preparation method based on Matrix Solid Phase Dispersion and Solid Phase Extraction Clean-up
    Rodriguez-Gonzalez, N.
    Gonzalez-Castro, M. J.
    Beceiro-Gonzalez, E.
    Muniategui-Lorenzo, S.
    Prada-Rodriguez, D.
    TALANTA, 2014, 121 : 194 - 198
  • [43] Development of sample preparation method for auxin analysis in plants by vacuum microwave-assisted extraction combined with molecularly imprinted clean-up procedure
    Yuling Hu
    Yuanwen Li
    Yi Zhang
    Gongke Li
    Yueqin Chen
    Analytical and Bioanalytical Chemistry, 2011, 399 : 3367 - 3374
  • [44] Development of sample preparation method for auxin analysis in plants by vacuum microwave-assisted extraction combined with molecularly imprinted clean-up procedure
    Hu, Yuling
    Li, Yuanwen
    Zhang, Yi
    Li, Gongke
    Chen, Yueqin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (10) : 3367 - 3374
  • [45] Development of an on-line automated sample clean-up method and liquid chromatography–tandem mass spectrometry analysis: application in an in vitro proteolytic assay
    Dieter Drexler
    Deborah J. Barlow
    Paul Falk
    Joseph Cantone
    Dennis Hernandez
    Asoka Ranasinghe
    Mark Sanders
    Bethanne Warrack
    Fiona McPhee
    Analytical and Bioanalytical Chemistry, 2006, 384 : 1145 - 1154
  • [46] A rapid clean-up method for the quantitation of 5-hydroxymethyl-2-furaldehyde in thermally treated abalone (Haliotis discus) muscle by HPLC-MS/MS
    Xu, Xianbing
    Feng, Tingting
    Zhang, Jing
    Ma, Yunjiao
    Song, Liang
    ANALYTICAL METHODS, 2018, 10 (42) : 5091 - 5096
  • [47] A novel analytical method for determining total polychlorinated biphenyl concentrations in fish and shellfish using a simple and rapid clean-up followed by GC-MS/MS
    Tsutsumi, Tomoaki
    Kawashima, Ayato
    Hamada, Noriaki
    Adachi, Rika
    Akiyama, Hiroshi
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2021, 96
  • [48] Development of new-type rapid analysis technology of polychlorinated biphenyls by using liquid chromatographic clean-up material (polyvinyl alcohol gel)
    Sawatsubashi, Tetsuya
    Tsukahara, Chisato
    Baba, Keigo
    Ohi, Etsumasa
    Shinoda, Akiko
    Miura, Norio
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1177 (01) : 138 - 149
  • [49] Development of an on-line automated sample clean-up method and liquid chromatography-tandem mass spectrometry analysis: application in an in vitro proteolytic assay
    Drexler, D
    Barlow, DJ
    Falk, P
    Cantone, J
    Hernandez, D
    Ranasinghe, A
    Sanders, M
    Warrack, B
    McPhee, F
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (05) : 1145 - 1154
  • [50] Development and validation of a fully automated LC method for the determination of cloxacillin in human plasma using anion exchancre restricted access material for sample clean-up
    Rbeida, O
    Chiap, P
    Lubda, D
    Boos, KS
    Crommen, J
    Hubert, P
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 36 (05) : 961 - 968