Fabrication of a polystyrene microfluidic chip coupled to electrospray ionization mass spectrometry for protein analysis

被引:17
|
作者
Hu, Xianqiao [1 ,2 ,3 ]
Dong, Yuanyuan [2 ]
He, Qiaohong [2 ]
Chen, Hengwu [2 ]
Zhu, Zhiwei [1 ,3 ]
机构
[1] China Natl Rice Res Inst, Hangzhou 310006, Zhejiang, Peoples R China
[2] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
[3] Minist Agr, Lab Qual & Safety Risk Assessment Rice Hangzhou, Hangzhou, Zhejiang, Peoples R China
关键词
Microfluidic chip; Electrospray ionization-mass spectrometry; Polystyrene; Immobilized enzymatic reactor; Gold film electric contact; Interface; CAPILLARY-ELECTROPHORESIS; EMITTER; SEPARATION; PROTEOMICS; MICROCHIP; DIGESTION; TIP; MS;
D O I
10.1016/j.jchromb.2015.03.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly integrated polystyrene (PS) microfluidic chip coupled to electrospray ionization mass spectrometry for on-chip protein digestion and online analysis was developed. The immobilized enzymatic microreactor for on-chip protein digestion was integrated onto microchip via the novel method of region-selective UV-modification combined with glutaraldehyde-based immobilization. The micro film electric contact for applying high voltage was prepared on chips by using UV-directed electroless plating technique. A micro-tip was machined at the end of main channel, serving as the interface between microchip and mass spectrometric detector. On-chip digestion and online detection of protein was carried out by coupling the microchip with mass spectrometry (MS). The influences of methanol flow rate in side channel on the stability of spray and intensity of signals were investigated systematically. Also the influence of sample flow rate on the performance of immobilized enzymatic reactor were investigated. Stable spray was obtained at the spray voltage of 2.8-3.0 kV and the methanol flow rate of 500-700 nL min(-1) with the relative standard deviation (RSD) of total ion current (TIC) less than 10%. The influence of sample flow rate on the performance of immobilized enzymatic reactor was also studied. The sequence coverage of protein identification decreased with the increase of flow rate of the sample solution. A sequence coverage of 96% was obtained with immobilized enzymatic reactor at the sample flow rate of 100 nL min(-1) with the reaction time of 8.4 min. It could detect cytochrome c as low as 10 mu g mL(-1) with the developed system. No obvious decrease in protein digestion efficiency was observed after the chip continuously performed for 4 h and stored for 15 d. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:96 / 103
页数:8
相关论文
共 50 条
  • [41] Direct Analysis of Biofluids by Mass Spectrometry with Microfluidic Voltage-Assisted Liquid Desorption Electrospray Ionization
    Li, Xiangtang
    Xu, Rui
    We, Xin
    Hu, Hankun
    Zhao, Shulin
    Liu, Yi-Ming
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12014 - 12022
  • [42] Interfacing microchip isoelectric focusing with on-chip electrospray ionization mass spectrometry
    Nordman, Nina
    Lauren, Susanna
    Kotiaho, Tapio
    Franssila, Sami
    Kostiainen, Risto
    Sikanen, Tiina
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1398 : 121 - 126
  • [43] About the Electrospray Ionization Source in Mass Spectrometry: Electrochemistry and On-chip Reactions
    Prudent, Michel
    Mendez, Manuel A.
    Roussel, Christophe
    Su, Bin
    Lion, Niels
    Rossier, Joel S.
    Girault, Hubert H.
    [J]. CHIMIA, 2009, 63 (05) : 283 - 287
  • [44] Analysis of Peptides in Plasma by High Performance Liquid Chromatography coupled with Electrospray Ionization Mass Spectrometry
    Fang, Haiyan
    Liu, Yin
    Wang, Shufang
    [J]. MECHANICAL PROPERTIES OF MATERIALS AND INFORMATION TECHNOLOGY, 2012, 340 : 273 - 279
  • [45] Analysis of triterpenoids in Ganoderma lucidum using liquid chromatography coupled with electrospray ionization mass spectrometry
    Yang, Min
    Wang, Xiaoming
    Guan, Shuhong
    Xia, Jiameng
    Sun, Jianghao
    Guo, Hui
    Guo, De-an
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (05) : 927 - 939
  • [46] On the Use of Electrospray Ionization and Desorption Electrospray Ionization Mass Spectrometry for Bulk and Surface Polymer Analysis
    Bonnaire, Nicolas
    Dannoux, Adeline
    Pernelle, Christine
    Amekraz, Badia
    Moulin, Christophe
    [J]. APPLIED SPECTROSCOPY, 2010, 64 (07) : 810 - 818
  • [47] Thin layer chromatography coupled with electrospray ionization mass spectrometry for direct analysis of raw samples
    Hu, Bin
    Xin, Gui-Zhong
    So, Pui-Kin
    Yao, Zhong-Ping
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1415 : 155 - 160
  • [48] Analysis of isoflavones in soy drink by capillary zone electrophoresis coupled with electrospray ionization mass spectrometry
    Bustamante-Rangel, M.
    Delgado-Zamarreno, M. M.
    Carabias-Martinez, R.
    Dominguez-Alvarez, J.
    [J]. ANALYTICA CHIMICA ACTA, 2012, 709 : 113 - 119
  • [49] Analysis of phenolic compounds in rhubarbs using liquid chromatography coupled with electrospray ionization mass spectrometry
    Ye, Min
    Han, Jian
    Chen, Hubiao
    Zheng, Junhua
    Guo, Dean
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (01) : 82 - 91
  • [50] Quantitative analysis of acrylamide in tea by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Liu, He
    Zhao, Ganghua
    Yuan, Yuan
    Chen, Fang
    Hu, Xiaosong
    [J]. FOOD CHEMISTRY, 2008, 108 (02) : 760 - 767