Fabrication of a polystyrene microfluidic chip coupled to electrospray ionization mass spectrometry for protein analysis

被引:17
|
作者
Hu, Xianqiao [1 ,2 ,3 ]
Dong, Yuanyuan [2 ]
He, Qiaohong [2 ]
Chen, Hengwu [2 ]
Zhu, Zhiwei [1 ,3 ]
机构
[1] China Natl Rice Res Inst, Hangzhou 310006, Zhejiang, Peoples R China
[2] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
[3] Minist Agr, Lab Qual & Safety Risk Assessment Rice Hangzhou, Hangzhou, Zhejiang, Peoples R China
关键词
Microfluidic chip; Electrospray ionization-mass spectrometry; Polystyrene; Immobilized enzymatic reactor; Gold film electric contact; Interface; CAPILLARY-ELECTROPHORESIS; EMITTER; SEPARATION; PROTEOMICS; MICROCHIP; DIGESTION; TIP; MS;
D O I
10.1016/j.jchromb.2015.03.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly integrated polystyrene (PS) microfluidic chip coupled to electrospray ionization mass spectrometry for on-chip protein digestion and online analysis was developed. The immobilized enzymatic microreactor for on-chip protein digestion was integrated onto microchip via the novel method of region-selective UV-modification combined with glutaraldehyde-based immobilization. The micro film electric contact for applying high voltage was prepared on chips by using UV-directed electroless plating technique. A micro-tip was machined at the end of main channel, serving as the interface between microchip and mass spectrometric detector. On-chip digestion and online detection of protein was carried out by coupling the microchip with mass spectrometry (MS). The influences of methanol flow rate in side channel on the stability of spray and intensity of signals were investigated systematically. Also the influence of sample flow rate on the performance of immobilized enzymatic reactor were investigated. Stable spray was obtained at the spray voltage of 2.8-3.0 kV and the methanol flow rate of 500-700 nL min(-1) with the relative standard deviation (RSD) of total ion current (TIC) less than 10%. The influence of sample flow rate on the performance of immobilized enzymatic reactor was also studied. The sequence coverage of protein identification decreased with the increase of flow rate of the sample solution. A sequence coverage of 96% was obtained with immobilized enzymatic reactor at the sample flow rate of 100 nL min(-1) with the reaction time of 8.4 min. It could detect cytochrome c as low as 10 mu g mL(-1) with the developed system. No obvious decrease in protein digestion efficiency was observed after the chip continuously performed for 4 h and stored for 15 d. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:96 / 103
页数:8
相关论文
共 50 条
  • [21] Electrospray ionization mass spectrometry
    Banks, JF
    Whitehouse, CM
    [J]. HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT A, 1996, 270 : 486 - 519
  • [22] Electrospray Ionization for Mass Spectrometry
    不详
    [J]. LC GC NORTH AMERICA, 2012, 30 (02) : 182 - 182
  • [23] Delayed Desorption Improves Protein Analysis by Desorption Electrospray Ionization Mass Spectrometry
    Maser, Tara L.
    Honarvar, Elahe
    Venter, Andre R.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (04) : 803 - 811
  • [24] Delayed Desorption Improves Protein Analysis by Desorption Electrospray Ionization Mass Spectrometry
    Maser, Tara L.
    Honarvar, Elahe
    Venter, Andre R.
    [J]. Journal of the American Society for Mass Spectrometry, 2020, 31 (04): : 803 - 811
  • [25] Poly(dimethylsiloxane)-based microfluidic device with electrospray ionization-mass spectrometry interface for protein identification
    Sung, WC
    Huang, SY
    Liao, PC
    Lee, GB
    Li, CW
    Chen, SH
    [J]. ELECTROPHORESIS, 2003, 24 (21) : 3648 - 3654
  • [26] Analysis of protein folding equilibria by nano-electrospray-ionization mass spectrometry
    Matecko, I
    Müller, N
    Grandori, R
    [J]. SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2002, 16 (3-4): : 361 - 370
  • [27] Quantifying Carbohydrate-Protein Interactions by Electrospray Ionization Mass Spectrometry Analysis
    El-Hawiet, Amr
    Kitova, Elena N.
    Klassen, John S.
    [J]. BIOCHEMISTRY, 2012, 51 (21) : 4244 - 4253
  • [28] Analysis of tomato glycoalkaloids by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Cataldi, TRI
    Lelario, F
    Bufo, SA
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (21) : 3103 - 3110
  • [29] PEPTIDE AND PROTEIN-ANALYSIS BY ELECTROSPRAY IONIZATION MASS-SPECTROMETRY AND CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY
    LOO, JA
    UDSETH, HR
    SMITH, RD
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 179 (02) : 404 - 412
  • [30] Application of electrospray ionization mass spectrometry to the analysis of oligodeoxynucleotides
    Iden, CR
    Rieger, RA
    Torres, MC
    Martin, LB
    [J]. BIOCHEMICAL AND BIOTECHNOLOGICAL APPLICATIONS OF ELECTROSPRAY IONIZATION MASS SPECTROMETRY, 1996, 619 : 281 - 293