Transient endothelial dysfunction following flow-mediated dilation assessment

被引:15
|
作者
Nerla, Roberto [2 ]
Di Monaco, Antonio [2 ]
Sestito, Alfonso [2 ]
Lamendola, Priscilla [2 ]
Di Stasio, Enrico [3 ]
Romitelli, Federica [3 ]
Lanza, Gaetano Antonio [1 ,2 ]
Crea, Filippo [2 ]
机构
[1] Univ Cattolica Sacro Cuore, Ist Cardiol, I-00168 Rome, Italy
[2] Univ Cattolica Sacro Cuore, Dipartimento Med Cardiovasc, I-00168 Rome, Italy
[3] Univ Cattolica Sacro Cuore, Ist Biochim & Biochim Clin, I-00168 Rome, Italy
关键词
Flow mediated dilation; Arginine; Endothelial function; CORONARY-ARTERY-DISEASE; NITRIC-OXIDE SYNTHESIS; ASYMMETRIC DIMETHYLARGININE; CARDIOVASCULAR RISK; L-ARGININE; ENDOGENOUS INHIBITOR; BRACHIAL-ARTERY; DIMETHYLAMINOHYDROLASE; VASODILATION; AUGMENTATION;
D O I
10.1007/s00380-010-0087-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Flow-mediated dilation (FMD) is a widely used tool to investigate endothelial function. However, FMD assessment may cause mechanical damage to the arterial endothelium. In this study we investigated the effect of FMD assessment on endothelial function. We studied 20 healthy subjects (26 +/- 6 years; 12 males). FMD was assessed by measuring brachial artery dilation in response to hyperemia after 5 min of forearm cuff inflation. Subjects were studied on 2 subsequent days. On day 1 they underwent two consecutive FMD measures, with the second test (FMD2) performed 15 min after the first test (FMD1). On day 2, the subjects were randomized to receive either placebo (saline) or intravenous L-arginine (10 g in 20 min). At the end of the infusion, patients underwent two consecutive FMD measures following the same protocol as on day 1. Asymmetric dimethyl-arginine (ADMA) serum levels were assessed on day 2 before FMD1 and FMD2. On day 1, FMD2 was lower than FMD1 in both groups (placebo 6.47 +/- 2.1 vs. 7.86 +/- 1.8%, P < 0.01; arginine 6.13 +/- 2.6 vs. 7.76 +/- 2.7%, P < 0.01). On day 2, a significant reduction of FMD was observed during FMD2 compared to FMD1 in the placebo group (5.82 +/- 1.7 vs. 7.44 +/- 2.2%, P < 0.001), but not in the arginine group (7.19 +/- 1.5 vs. 7.27 +/- 1.5, P = 0.67). ADMA levels significantly increased compared to baseline after FMD1 (0.59 +/- 0.12-0.91 +/- 0.64 mu mol/l, P = 0.036), with similar changes in the two groups. FMD assessment induces a significant impairment of endothelial function. An increase of endogenous NO synthesis inhibitors seems responsible for the phenomenon that is reversed by L-arginine administration.
引用
收藏
页码:524 / 529
页数:6
相关论文
共 50 条
  • [21] Endothelial dysfunction as assessed by flow-mediated dilation in patients with cardiac syndrome X: role of inflammation
    Tondi, P.
    Santoliquido, A.
    Di Giorgio, A.
    Sestito, A.
    Sgueglia, G. A.
    Flore, R.
    Careri, G.
    Pinnacchio, G.
    Lanza, G. A.
    Crea, F.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2011, 15 (09) : 1074 - 1077
  • [22] Flow-mediated dilation of the brachial artery and endothelial dysfunction in subcutaneous small resistance arteries.
    Muiesan, M
    Rizzoni, D
    Salvetti, M
    Porteri, E
    Monteduro, C
    Guelfi, D
    Corbellini, C
    Agabiti-Rosei, E
    JOURNAL OF HYPERTENSION, 2000, 18 : S227 - S227
  • [23] Endothelial Dysfunction in Patients With Coronary Artery Disease: Insights From a Flow-Mediated Dilation Study
    Manganaro, Agatino
    Ciraci, Luca
    Andre, Laura
    Trio, Olimpia
    Manganaro, Roberta
    Saporito, Francesco
    Oreto, Giuseppe
    Ando, Giuseppe
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2014, 20 (06) : 583 - 588
  • [24] Hypertension preserves the magnitude of microvascular flow-mediated dilation following transient elevation in intraluminal pressure
    Hughes, William E.
    Zinkevich, Natalya
    Gutterman, David D.
    Beyer, Andreas M.
    PHYSIOLOGICAL REPORTS, 2021, 9 (03):
  • [25] Time Course of Flow-Mediated Dilation and Vascular Endothelial Growth Factor following Acute Stroke
    Billinger, Sandra A.
    Sisante, Jason-Flor V.
    Whitaker, Alicen A.
    Abraham, Michael G.
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2018, 27 (04): : 957 - 962
  • [26] Flow-mediated slowing shows poor repeatability compared with flow-mediated dilation in non-invasive assessment of brachial artery endothelial function
    Maroco, Joao Luis
    Pinto, Marco
    Santa-Clara, Helena
    Fernhall, Bo
    Melo, Xavier
    PLOS ONE, 2022, 17 (05):
  • [27] Relationship between flow-mediated dilation of the brachial artery and endothelial dysfunction in subcutaneous small resistance arteries
    Muiesan, ML
    Rizzoni, D
    Salvetti, M
    Porteri, E
    Monteduro, C
    Guelfi, D
    Corbellini, C
    Agabiti-Rosei, E
    EUROPEAN HEART JOURNAL, 2000, 21 : 317 - 317
  • [28] ASSESSMENT OF ENDOTHELIAL FUNCTION BY FLOW-MEDIATED DILATION IN WELL-CONTROLLED PATIENTS WITH RHEUMATOID ARTHRITIS
    Anyfanti, Panagiota
    Nikolaidou, Barbara
    Triantafyllou, Areti
    Gavriilaki, Eleni
    Angeloudi, Elena
    Malliora, Anastasia
    Dimitroulas, Theodoros
    Doumas, Michalis
    Gkaliagkousi, Eugenia
    JOURNAL OF HYPERTENSION, 2023, 41 : E208 - E209
  • [29] Antioxidants and Endothelial Dysfunction in Young and Elderly People: Is Flow-Mediated Dilation Useful to Assess Acute Effects?
    Tsikas, Dimitrios
    Flentje, Markus
    Niemann, Jonas
    Modun, Darko
    HYPERTENSION, 2012, 60 (01) : E5 - E5
  • [30] Endothelial Function Assessment by Flow-Mediated Dilation Method: A Valuable Tool in the Evaluation of the Cardiovascular System
    Mucka, Szymon
    Miodonska, Martyna
    Jakubiak, Grzegorz K.
    Starzak, Monika
    Cieslar, Grzegorz
    Stanek, Agata
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (18)