Flow-mediated slowing shows poor repeatability compared with flow-mediated dilation in non-invasive assessment of brachial artery endothelial function

被引:1
|
作者
Maroco, Joao Luis [1 ,2 ]
Pinto, Marco [1 ]
Santa-Clara, Helena [2 ]
Fernhall, Bo [3 ]
Melo, Xavier [1 ,2 ]
机构
[1] Ginasio Clube Portugues, Res & Dev Dept, GCP Lab, Lisbon, Portugal
[2] Univ Lisbon, Fac Motr Humana, Ctr Interdisciplinar Estudo Performance Humana, Oeiras, Portugal
[3] Univ Illinois, Coll Appl Hlth Sci, Chicago, IL USA
来源
PLOS ONE | 2022年 / 17卷 / 05期
关键词
PULSE-WAVE VELOCITY; DILATATION; REPRODUCIBILITY; RELIABILITY; DYSFUNCTION; SPHYGMOCOR; INDEX;
D O I
10.1371/journal.pone.0267287
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Pulse wave velocity (PWV) deceleration to reactive hyperemia-flow-mediated slowing (FMS)-has been suggested as an alternative method to flow-mediated dilation (FMD) to evaluate brachial artery endothelial function. FMS is suggested to address major caveats of the FMD procedure including its suboptimal repeatability and high-operator dependency. However, the repeatability of FMS has not been thoroughly examined, especially given the plethora of methods claiming to measure PWV. We assessed and compared the intra- and inter-day repeatability of FMS as measured by piezoelectric pressure mechanotransducers placed in the carotid and radial arteries, and brachial artery FMD as measured by echo-tracking. Twenty-four healthy male participants aged 23-75 yr, were examined on three separate days to assess intra and inter-day repeatability. All FMD and FMS examinations were conducted simultaneously by the same researcher complying with standardized guidelines. Repeatability was examined with intraclass correlation coefficient (ICC; >0.80), coefficient of variation (CV; <15%), and limits of agreement (95% LOA). Relative (%) FMD and FMS were scaled for baseline brachial artery diameter and PWV, respectively. Intra- (ICC: 0.72; CV: 136%; 95% LOA: -19.38 to 29.19%) and Inter-day (ICC: 0.69; CV: 145%, 95% LOA: -49.50 to 46.08%) repeatability of %FMS was poor, whereas %FMD demonstrated moderate-to-good intra- (ICC: 0.93; CV: 18%, 95% LOA: -3.02 to 3.75%) and inter-day repeatability (ICC: 0.74; CV: 25%, 95% LOA: -9.16 to 7.04%). Scaling FMD reduced the intra-day CV (-5%), and the uncertainty of the 95% LOA (- 37.64 to 35.69%) estimates of FMS. Carotid-radial artery FMS showed poorer repeatability compared to FMD.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Limitations of non-invasive endothelial function assessment by brachial artery flow-mediated dilatation
    Sejda, T
    Pitha, J
    Svandová, E
    Poledne, R
    [J]. ATHEROSCLEROSIS SUPPLEMENTS, 2005, 6 (01) : 130 - 130
  • [2] Limitations of non-invasive endothelial function assessment by brachial artery flow-mediated dilatation
    Sejda, T
    Pit'ha, J
    Svandová, E
    Poledne, R
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2005, 25 (01) : 58 - 61
  • [3] Intra and inter-rater repeatability of brachial artery ultrasound estimates of flow-mediated slowing and flow-mediated dilation
    Maroco, Joao Luis
    Silvestre, Tiago
    Arrais, Ines
    Pinto, Marco
    Santa-Clara, Helena
    Fernhall, Bo
    Melo, Xavier
    [J]. PLOS ONE, 2023, 18 (06):
  • [4] Use of Ultrasound for Non-Invasive Assessment of Flow-Mediated Dilation
    Stoner, Lee
    Sabatier, Manning J.
    [J]. JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2012, 19 (05) : 407 - 421
  • [5] Measurement of endothelial function by brachial artery flow-mediated vasodilation
    Vogel, RA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (2A): : 31E - 34E
  • [6] Stability and reproducibility of brachial artery flow-mediated dilation
    Welsch, MA
    Allen, JD
    Geaghan, JP
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (06): : 960 - 965
  • [7] Flow-mediated dilation shows impaired endothelial function in patients with mastocytosis
    Bucci, Tommaso
    Parente, Roberta
    De Feo, Giulia
    Cardamone, Chiara
    Triggiani, Massimo
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2019, 144 (04) : 1106 - 1111
  • [8] Flow-Mediated Dilation (FMD) and Peripheral Endothelial Function Assessment
    Shechter, Michael
    [J]. JOURNAL OF VASCULAR RESEARCH, 2019, 56 : 100 - 100
  • [9] Microvascular endothelial glycocalyx thickness is associated with brachial artery flow-mediated dilation
    Smilowitz, Nathaniel R.
    Luttrell-Williams, Elliot
    Golpanian, Michael
    Engel, Alexis
    Buyon, Jill P.
    Katz, Stuart D.
    Berger, Jeffrey S.
    [J]. VASCULAR MEDICINE, 2021, 26 (05) : 563 - 565
  • [10] Flow-mediated dilation of the brachial artery and endothelial dysfunction in different COPD phenotypes
    Dugac, Andrea Vukic
    Ruzic, Alen
    Popovic-Grle, Sanja
    Hecimovic, Ana
    Makek, Mateja Jankovic
    Samarzija, Miroslav
    Jakopovic, Marko
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2015, 46