On the Use of Optically Stimulated Luminescent Dosimeter for Surface Dose Measurement during Radiotherapy

被引:37
|
作者
Yusof, Fasihah Hanum [1 ]
Ung, Ngie Min [2 ]
Wong, Jeannie Hsiu Ding [1 ,3 ]
Jong, Wei Loong [1 ]
Ath, Vannyat [1 ]
Phua, Vincent Chee Ee [2 ]
Heng, Siew Ping [4 ]
Ng, Kwan Hoong [1 ,3 ]
机构
[1] Univ Malaya, Fac Med, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[2] Univ Malaya, Fac Med, Clin Oncol Unit, Kuala Lumpur, Malaysia
[3] Univ Malaya, Fac Med, Res Imaging Ctr, Kuala Lumpur, Malaysia
[4] Pantai Hosp Kuala Lumpur, Inst Canc, Kuala Lumpur, Malaysia
来源
PLOS ONE | 2015年 / 10卷 / 06期
关键词
BREAST-CANCER; CHEST-WALL; CONTRALATERAL BREAST; 2ND PRIMARY; SKIN; PHOTON; HEAD; FILM; OSL; ASSOCIATION;
D O I
10.1371/journal.pone.0128544
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study was carried out to investigate the suitability of using the optically stimulated luminescence dosimeter (OSLD) in measuring surface dose during radiotherapy. The water equivalent depth (WED) of the OSLD was first determined by comparing the surface dose measured using the OSLD with the percentage depth dose at the buildup region measured using a Markus ionization chamber. Surface doses were measured on a solid water phantom using the OSLD and compared against the Markus ionization chamber and Gafchromic EBT3 film measurements. The effect of incident beam angles on surface dose was also studied. The OSLD was subsequently used to measure surface dose during tangential breast radiotherapy treatments in a phantom study and in the clinical measurement of 10 patients. Surface dose to the treated breast or chest wall, and on the contralateral breast were measured. The WED of the OSLD was found to be at 0.4 mm. For surface dose measurement on a solid water phantom, the Markus ionization chamber measured 15.95% for 6 MV photon beam and 12.64% for 10 MV photon beam followed by EBT3 film (23.79% and 17.14%) and OSLD (37.77% and 25.38%). Surface dose increased with the increase of the incident beam angle. For phantom and patient breast surface dose measurement, the response of the OSLD was higher than EBT3 film. The in-vivo measurements were also compared with the treatment planning system predicted dose. The OSLD measured higher dose values compared to dose at the surface (Hp(0.0)) by a factor of 2.37 for 6 MV and 2.01 for 10 MV photon beams, respectively. The measurement of absorbed dose at the skin depth of 0.4 mm by the OSLD can still be a useful tool to assess radiation effects on the skin dermis layer. This knowledge can be used to prevent and manage potential acute skin reaction and late skin toxicity from radiotherapy treatments.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Optically-Stimulated Luminescent Dosimeters for Monitoring Pacemaker Dose in Radiation Therapy
    Apicello, L.
    Riegel, A.
    Jamshidi, A.
    MEDICAL PHYSICS, 2015, 42 (06) : 3470 - 3470
  • [42] Optically stimulated luminescent dosimeters stable response to dose after repeated bleaching
    Jursinic, Paul A.
    MEDICAL PHYSICS, 2020, 47 (07) : 3191 - 3203
  • [43] Surface mount multilayer ceramic capacitors as optically stimulated luminescent dosimeters
    Panda, Madhusmita
    Joshi, Shailesh
    Annalakshmi, O.
    Srinivas, C. V.
    Venkatraman, B.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 213
  • [44] High Accuracy Measurement of Absorbed Dose to Water Using Optically Stimulated Luminescence Dosimeter in High-Energy Photon Beam Field
    Goto, S.
    Hayashi, H.
    Yamaguchi, H.
    Shimizu, M.
    Akino, R.
    Sekiguchi, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E789 - E789
  • [45] Organ dose measurement using Optically Stimulated Luminescence Detector (OSLD) during CT examination
    Yusuf, Muhammad
    Alothmany, Nazeeh
    Kinsara, Abdulraheem Abdulrahman
    RADIATION PHYSICS AND CHEMISTRY, 2017, 139 : 83 - 89
  • [46] Dosimetry of Al2O3 optically stimulated luminescent dosimeter at high energy photons and electrons
    Yusof, M. F. Mohd
    Joohari, N. A.
    Abdullah, R.
    Abd Shukor, N. S.
    Abd Kadir, A. B.
    Isa, N. Mohd
    INTERNATIONAL NUCLEAR SCIENCE, TECHNOLOGY AND ENGINEERING CONFERENCE 2017 (INUSTEC2017), 2018, 298
  • [47] Feasibility study of an optically-stimulated luminescent nanodot dosimeter (OSLnD) in high-energy photon beams
    Kim, Jin-Young
    Park, Sung-Kwang
    Kim, Yon-Lae
    Suh, Tae-Suk
    Shin, Jung-Wook
    Oh, Kyoung-Min
    Nam, Sang-Hee
    Kim, Jong-Eon
    Min, Byung-In
    Jo, Sun-Mi
    Oh, Won-Young
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (07) : 1159 - 1163
  • [48] Feasibility study of an optically-stimulated luminescent nanodot dosimeter (OSLnD) in high-energy photon beams
    Jin-Young Kim
    Sung-Kwang Park
    Yon-Lae Kim
    Tae-Suk Suh
    Jung-Wook Shin
    Kyoung-Min Oh
    Sang-Hee Nam
    Jong-Eon Kim
    Byung-In Min
    Sun-Mi Jo
    Won-Young Oh
    Journal of the Korean Physical Society, 2014, 65 : 1159 - 1163
  • [49] Measurement of surface dose in an MR-Linac with optically stimulated luminescence dosimeters for IMRT beam geometries
    Lim-Reinders, Stephanie
    Keller, Brian M.
    Sahgal, Arjun
    Chugh, Brige
    Kim, Anthony
    MEDICAL PHYSICS, 2020, 47 (07) : 3133 - 3142
  • [50] Technical Note: Precision and accuracy of a commercially available CT optically stimulated luminescent dosimetry system for the measurement of CT dose index
    Vrieze, Thomas J.
    Sturchio, Glenn M.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2012, 39 (11) : 6580 - 6584