Dorsal intercarpal ligament capsulodesis for scapholunate dissociation: Biomechanical analysis in a cadaver model

被引:74
|
作者
Slater, RR [1 ]
Szabo, RM [1 ]
Bay, BK [1 ]
Laubach, L [1 ]
机构
[1] Univ Calif Davis, Dept Orthopaed Surg, Sacramento, CA 95817 USA
来源
关键词
scapholunate dissociation; capsulodesis; wrist; ligament;
D O I
10.1053/jhsu.1999.0232
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to evaluate in cadavers a new method for treating scapholunate dissociations, dorsal intercarpal ligament capsulodesis (DILC), and to compare its performance with that of a previously described soft tissue reconstruction, Blatt capsulodesis (BC). A cadaver model was used to simulate normal and abnormal wrist motions. The positions of the scaphoid and lunate and their changes with wrist motion and ligament condition were recorded using biplanar radiographs taken posteroanteriorly and laterally. The scapholunate gap was measured on the posteroanterior radiographs and the scapholunate angle was measured on the lateral view radiographs. Following scapholunate interosseous ligament sectioning, a diastasis developed between the scaphoid and lunate that was maximum in the clenched fist position 2.1 +/- 0.33 mm (mean +/- SEM) with the ligament intact versus 8.0 +/- 1.74 mm after the ligament was sectioned. Dorsal intercarpal ligament capsulodesis reduced gap formation more than BC, including when the specimens were in the clenched fist position: increased gap versus intact specimens equals 1.0 mm for DILC versus 3.7 mm for BC. The differences in diastasis were statistically significant between BC and DILC when the wrist was in extension, radial deviation, and clenched fist positions. After the scapholunate interosseous ligament was divided, the scaphoid flexed relative to the lunate. Both capsulodeses improved scapholunate alignment and there was a trend for DILC to correct the scapholunate angle more than BC. The results demonstrate that DILC is an attractive alternative to BC ex vivo. Because DILC does not tether the scaphoid to the distal radius, as BC does, improved wrist motion, especially flexion, might be possible in vivo. The use of DILC in the treatment of scapholunate dissociation warrants further investigation and clinical trials. Copyright (C) 1999 by the American Society for Surgery of the Hand.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 49 条
  • [31] The Influence of Thumb Metacarpophalangeal Joint Rotation on the Evaluation of Ulnar Collateral Ligament Injuries: A Biomechanical Study in a Cadaver Model
    Mayer, Stephanie W.
    Ruch, David S.
    Leversedge, Fraser J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (03): : 474 - 479
  • [32] Biomechanical analysis of pedicle screw thread differential design in an osteoporotic cadaver model
    Mehta, H.
    Santos, E.
    Ledonio, C.
    Sembrano, J.
    Ellingson, A.
    Pare, P.
    Murrell, B.
    Nuckley, D. J.
    CLINICAL BIOMECHANICS, 2012, 27 (03) : 234 - 240
  • [33] Refixation of the anterior cruciate ligament: A biomechanical analysis of suture techniques in a porcine model
    Lutter, Christoph
    Hiller, Natalie
    Sass, Jan-Oliver
    Hembus, Jessica
    Jones, Gareth
    Vogel, Danny
    Gross, Justus
    Bader, Rainer
    Tischer, Thomas
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (01)
  • [34] A visco-hyperelastic-damage constitutive model for the analysis of the biomechanical response of the periodontal ligament
    Natali, Arturo N.
    Carniel, Emanuele L.
    Pavan, Piero G.
    Sander, Franz G.
    Dorow, Christina
    Geiger, Martin
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (03):
  • [35] Biomechanical Stability of Volar Plate Only Versus Addition of Dorsal Ulnar Pin Plate: A Dorsal Ulnar Fragment, C-3-Type, Distal Radius, Cadaver Fracture Model
    Patrick, Nathan C.
    Lewis, Gregory S.
    Roush, Evan P.
    Black, Sarah S.
    Henderson, Stacy R.
    Taylor, Kenneth F.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (09) : E298 - E303
  • [36] Posterior atlantoaxial fixation of osteoporotic odontoid fracture: biomechanical analysis of the Magerl versus harms techniques in a cadaver model
    Mike-Mayer, Austin
    Lam, Kendrick
    Morris, Randal P.
    Al Barghouthi, Abeer
    Travascio, Francesco
    Latta, Loren L.
    Lindsey, Ronald W.
    SPINE JOURNAL, 2024, 24 (08): : 1510 - 1516
  • [37] Biomechanical Comparison of Dorsal Nail Plate Versus Screw and K-Wire Construct for Extra-Articular Distal Radius Fractures in a Cadaver Bone Model
    Klitscher, Daniela
    Mehling, Isabella
    Nowak, Lukas
    Nowak, Tobias
    Rornmens, Pol M.
    Mueller, Lars P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (04): : 611 - 618
  • [38] Using the Remnant Anterior Cruciate Ligament to Improve Knee Stability: Biomechanical Analysis Using a Cadaveric Model
    Nhan, Derek T.
    Belkoff, Stephen M.
    Singh, Prerna
    Sullivan, Brian T.
    Klyce, Walter
    Lee, R. Jay
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (04)
  • [39] Comparative biomechanical analysis of a cervical cage made of an unsintered hydroxyapatite particle and poly-L-lactide composite in a cadaver model
    Totoribe, K
    Matsumoto, M
    Goel, VK
    Yang, SJ
    Tajima, N
    Shikinami, Y
    SPINE, 2003, 28 (10) : 1010 - 1014
  • [40] A Biomechanical Analysis of 2 Constructs for Metacarpal Spiral Fracture Fixation in a Cadaver Model: 2 Large Screws Versus 3 Small Screws
    Cheah, Andre Eu-Jin
    Behn, Anthony W.
    Comer, Garet
    Yao, Jeffrey
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (12): : 1033.e1 - 1033.e6