Biomechanical Stability of Volar Plate Only Versus Addition of Dorsal Ulnar Pin Plate: A Dorsal Ulnar Fragment, C-3-Type, Distal Radius, Cadaver Fracture Model

被引:5
|
作者
Patrick, Nathan C. [1 ]
Lewis, Gregory S. [1 ]
Roush, Evan P. [1 ]
Black, Sarah S. [1 ]
Henderson, Stacy R. [2 ]
Taylor, Kenneth F. [1 ]
机构
[1] Penn State Milton S Hershey Med Ctr, Dept Orthopaed & Rehabil, 30 Hope Dr,POB 859, Hershey, PA 17033 USA
[2] Penn State Milton S Hershey Med Ctr, Dept Surg, Div Plast Surg, Hershey, PA USA
关键词
fixation; fracture; fragment specific; radius; volar plate; LOCKING PLATE; FIXATION; REDUCTION; SCREW; PART;
D O I
10.1097/BOT.0000000000001776
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To determine if the addition of a dorsal ulnar pin plate provides improved stability characteristics in the management of intra-articular distal radius fractures with an associated dorsal ulnar fragment. Methods: OTA/AO type C3 fractures, with a dorsal ulnar fragment of one-third or one-half the width of the distal radius, were simulated in 9 matched pairs of fresh-frozen cadaveric arms randomized between fixed-angle volar plate only versus volar plate with addition of a dorsal ulnar pin plate. Prepared specimens were mounted in a custom load frame and loaded in extension with stepwise cyclic load increase. Dorsal plane interfragmentary displacements were compared between the 2 fixation constructs at 50-N and 100-N cyclic load. Results: The addition of the dorsal ulnar pin plate significantly reduced interfragmentary displacements for the dorsal ulnar fragment at the 50 N load application, resulting in mean interfragmentary displacements of -0.1 +/- 0.2 mm in comparison to -0.3 +/- 0.2 mm with the volar plate-only construct. No other interfragmentary displacement comparisons were significant. No differences were found comparing the one-third and one-half size fragments. Conclusions: The addition of a dorsal ulnar pin plate improved stability characteristics with respect to the dorsal ulnar fragment.
引用
收藏
页码:E298 / E303
页数:6
相关论文
共 23 条
  • [1] Volar versus combined dorsal and volar plate fixation of complex intraarticular distal radius fractures with small dorsoulnar fragment - a biomechanical study
    Hadzhinikolova, Mariya
    Zderic, Ivan
    Ciric, Daniel
    Barcik, Jan P.
    Enchev, Dian
    Baltov, Asen
    Rusimov, Lyubomir
    Varga, Peter
    Stoffel, Karl
    Richards, Geoff
    Gueorguiev, Boyko
    Rashkov, Mihail
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [2] Volar versus combined dorsal and volar plate fixation of complex intraarticular distal radius fractures with small dorsoulnar fragment – a biomechanical study
    Mariya Hadzhinikolova
    Ivan Zderic
    Daniel Ciric
    Jan P. Barcik
    Dian Enchev
    Asen Baltov
    Lyubomir Rusimov
    Peter Varga
    Karl Stoffel
    Geoff Richards
    Boyko Gueorguiev
    Mihail Rashkov
    BMC Musculoskeletal Disorders, 23
  • [3] Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture? a biomechanical study
    Kandemir, Utku
    Matityahu, Amir
    Desai, Rohan
    Puttlitz, Christian
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (09) : 605 - 610
  • [4] Biomechanical stability of a fixed-angle volar plate versus fragment-specific fixation system: Cyclic testing in a C2-type distal radius cadaver fracture model
    Taylor, KF
    Parks, BG
    Segalman, KA
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (03): : 373 - 381
  • [5] Locking Plate for AO Type C Intra-articular Distal Radius Fracture: Volar or Dorsal Approach?
    Ka-Ho, Tsang
    Kai-Yiu, Choi
    Yat-Fai, Chan
    Shun-Chung, Lau
    Yuk-Yin, Chow
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2014, 18 (02) : 83 - 88
  • [6] Complications following dorsal versus volar plate fixation of distal radius fracture: A meta-analysis
    Wei, Jie
    Yang, Tu-Bao
    Luo, Wei
    Qin, Jia-Bi
    Kong, Fan-Jing
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (02) : 265 - 275
  • [7] Comminuted Dorsal Ulnar Fragment in Distal Radius Fractures Treated Using the Integrated Compression Screw With a Mini-Plate
    Sakamoto, Sotetsu
    Doi, Kazuteru
    Hattori, Yasunori
    AL-Bazzaz, Abdullah
    Hayashi, Kota
    Sonezaki, Shichoh
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (04): : 394.e1 - 394.e6
  • [8] Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: A retrospective study
    Rein, Susanne
    Schikore, Hartmut
    Schneiders, Wolfgang
    Amlang, Michael
    Zwipp, Hans
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (07): : 954 - 961
  • [9] Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model
    Grindel, Steven I.
    Wang, Mei
    Gerlach, Matthew
    McGrady, Linda M.
    Brown, Susan
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (02): : 194 - 199
  • [10] Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model
    Kamei, Shuzo
    Osada, Denju
    Tamai, Kazuya
    Kato, Nakayuki
    Takai, Morimitsu
    Kameda, Masahiro
    Nohara, Yutaka
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2010, 15 (03) : 357 - 364