Study of dural suture watertightness: an in vitro comparison of different sealants

被引:41
|
作者
Chauvet, Dorian [1 ,2 ]
Viet Tran [3 ]
Mutlu, Gurkan
George, Bernard [1 ,2 ]
Allain, Jean-Marc [3 ]
机构
[1] Grp Hosp Pitie Salpetriere, Dept Neurosurg, F-75014 Paris, France
[2] Lariboisiere Hosp, F-75014 Paris, France
[3] Ecole Polytech, Lab Solids Mech, Palaiseau, France
关键词
Cerebrospinal fluid leakage; Dural suture; In vitro study; Sealants; CEREBROSPINAL-FLUID LEAKS; HYDROGEL SEALANT; COLLAGEN FLEECE; FIBRIN GLUE; REPAIR; BIOGLUE(R); PREVENTION; ADHESIVE; CLOSURES; DUROTOMY;
D O I
10.1007/s00701-011-1197-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
CSF leakages constitute a major complication of intradural procedures, especially for posterior fossa and skull base surgery. Dural suture watertightness is a decisive issue, and neurosurgeons routinely use different products to reinforce their dural closure. We have designed an experimental system capable of testing CSF leak pressure levels in order to compare two types of sutures in vitro and particularly four different sealants. Twenty-five fresh human cadaveric dural samples were removed and prepared for testing in a pressure chamber system connected to a hydraulic pressure motor. CSF leak levels were objectively registered. First, simple interrupted stitches were compared to running simple closure on 50-mm linear suture. Secondly, four sealants (two sealants/glues, BioglueA (R), DurasealA (R); two haemostatics, TachosilA (R), TissucolA (R)) were tested. Statistical analysis was performed with paired Student's t-test. No significant difference between interrupted closure and running suture was observed (p = 0.079). All sealants increased the watertightness of the suture significatively. However, comparison of the means of the differences for each product revealed large variations. In the conditions of our experiment, one sealant (DurasealA (R)) and one haemostatic (TachosilA (R)) seemed to show better results. We observed two different types of leakage: at the dura-sealant interface and through the sealant itself. We have developed an experimental device capable of testing dural closure watertightness. Interrupted stitch suturing seemed no different from running simple closure. On the contrary, the sealants tested show different watertightness capacities.
引用
收藏
页码:2465 / 2472
页数:8
相关论文
共 50 条
  • [41] Watertight dural closure! An in vitro study to explore the myth
    Sengupta, Sudipkumar
    INDIAN JOURNAL OF NEUROSURGERY, 2013, 2 (01) : 77 - 80
  • [42] In vitro comparison of the locking loop and continuous cruciate suture patterns
    Renberg, WC
    Radlinsky, MG
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2001, 14 (01) : 15 - 18
  • [43] Biomechanical in vitro comparison of suture anchors for thumb UCL repair
    Wagner, M.
    Schmoelz, W.
    Stofferin, H.
    Arora, R.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (03) : 435 - 442
  • [44] Biomechanical in vitro comparison of suture anchors for thumb UCL repair
    M. Wagner
    W. Schmoelz
    H. Stofferin
    R. Arora
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 435 - 442
  • [45] Comparison of the accuracy of different types of bite recordings - an in vitro study
    Hellmann, Daniel
    Krumpa, Sarah
    Trautner, Patrick
    Schindler, Hans J.
    Schmitter, Marc
    Boldt, Julian
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (04)
  • [46] Antimicrobial comparison of four different mouthwashes.: An in vitro study
    Almas, K
    Mokeem, S
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 599 - 599
  • [47] Comparison of the accuracy of different types of bite recordings - an in vitro study
    Daniel Hellmann
    Sarah Krumpa
    Patrick Trautner
    Hans J. Schindler
    Marc Schmitter
    Julian Boldt
    Clinical Oral Investigations, 28
  • [48] Effects of Ozonated Water on Micro Leakage between Enamel and Fissure Sealants Prepared by Different Etching Technique (An in vitro Study)
    Jabar, Baraa M.
    Khalaf, Muna S.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2022, 10 (08): : 176 - 180
  • [49] Suture Autotransplantation and Dural Stripping for Craniosynostosis: A Long-Term Growth Study in Humans
    Mommaerts, Maurice Y.
    De Vos, Wouter
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (06) : 2014 - 2017
  • [50] Comparison between four different suture configurations for rotator cuff repair: a biomechanical animal study
    Haroun, Yahia
    Sobhy, Mohamed H.
    Khater, Hany A.
    Khater, Ahmad H.
    SICOT-J, 2024, 10