Study of dural suture watertightness: an in vitro comparison of different sealants

被引:41
|
作者
Chauvet, Dorian [1 ,2 ]
Viet Tran [3 ]
Mutlu, Gurkan
George, Bernard [1 ,2 ]
Allain, Jean-Marc [3 ]
机构
[1] Grp Hosp Pitie Salpetriere, Dept Neurosurg, F-75014 Paris, France
[2] Lariboisiere Hosp, F-75014 Paris, France
[3] Ecole Polytech, Lab Solids Mech, Palaiseau, France
关键词
Cerebrospinal fluid leakage; Dural suture; In vitro study; Sealants; CEREBROSPINAL-FLUID LEAKS; HYDROGEL SEALANT; COLLAGEN FLEECE; FIBRIN GLUE; REPAIR; BIOGLUE(R); PREVENTION; ADHESIVE; CLOSURES; DUROTOMY;
D O I
10.1007/s00701-011-1197-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
CSF leakages constitute a major complication of intradural procedures, especially for posterior fossa and skull base surgery. Dural suture watertightness is a decisive issue, and neurosurgeons routinely use different products to reinforce their dural closure. We have designed an experimental system capable of testing CSF leak pressure levels in order to compare two types of sutures in vitro and particularly four different sealants. Twenty-five fresh human cadaveric dural samples were removed and prepared for testing in a pressure chamber system connected to a hydraulic pressure motor. CSF leak levels were objectively registered. First, simple interrupted stitches were compared to running simple closure on 50-mm linear suture. Secondly, four sealants (two sealants/glues, BioglueA (R), DurasealA (R); two haemostatics, TachosilA (R), TissucolA (R)) were tested. Statistical analysis was performed with paired Student's t-test. No significant difference between interrupted closure and running suture was observed (p = 0.079). All sealants increased the watertightness of the suture significatively. However, comparison of the means of the differences for each product revealed large variations. In the conditions of our experiment, one sealant (DurasealA (R)) and one haemostatic (TachosilA (R)) seemed to show better results. We observed two different types of leakage: at the dura-sealant interface and through the sealant itself. We have developed an experimental device capable of testing dural closure watertightness. Interrupted stitch suturing seemed no different from running simple closure. On the contrary, the sealants tested show different watertightness capacities.
引用
收藏
页码:2465 / 2472
页数:8
相关论文
共 50 条
  • [31] COMPARISON OF DIFFERENT TECHNIQUES USED TO IMPROVE THE SEALANTS ADHESION ON ENAMEL SURFACE
    Rotaru, A.
    Teslaru, T.
    Chirap, I.
    Prodan, A. M.
    Dumitrascu, N.
    ROMANIAN JOURNAL OF PHYSICS, 2016, 61 (3-4): : 666 - 675
  • [32] In vitro evaluation of shear bond strength and microleakage of different pit and fissure sealants
    Babaji, Prashant
    Vaid, Shivali
    Deep, S.
    Mishra, Samvit
    Srivastava, Madhulika
    Manjooran, Thomas
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2016, 6 : 111 - 115
  • [33] Toothbrush-Dentifrice Abrasion of Dental Sealants: An In Vitro Study
    Sangpanya, Angkhana
    Fuangtharnthip, Pornpoj
    Nimmanon, Vanida
    Pachimsawat, Praewpat
    EUROPEAN JOURNAL OF DENTISTRY, 2022, 16 (03) : 549 - 556
  • [34] Retention of sealants during orthodontic treatment: An in vitro comparison of two etching protocols
    Chau, Christopher
    Campbell, Phillip M.
    Deljavan, Nima
    Taylor, Reginald W.
    Buschang, Peter H.
    ANGLE ORTHODONTIST, 2015, 85 (05) : 750 - 756
  • [35] Comparison of a multifilament stainless steel suture with FiberWire for flexor tendon repairs - an in vitro biomechanical study
    McDonald, E.
    Gordon, J. A.
    Buckley, J. M.
    Gordon, L.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38E (04) : 418 - 423
  • [36] Comparison of 3 different releasable suture techniques in trabeculectomy
    Duman, Fulya
    Faria, Bruno
    Rutnin, Nont
    Guzel, Huseyin
    Ekici, Feyzahan
    Waisbourd, Michael
    Katz, L. Jay
    Moster, Marlene R.
    Spaeth, George L.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (04) : 307 - 314
  • [37] In vitro comparison of three materials as apical sealants of equine premolar and molar teeth
    Steenkamp, G
    Olivier-Carstens, A
    van Heerden, WFP
    Crossley, DA
    Boy, SC
    EQUINE VETERINARY JOURNAL, 2005, 37 (02) : 133 - 136
  • [38] Tenorrhaphy in horses: comparison of the mechanical properties of two different suture patterns and suture materials
    Correa, R. R.
    Pereira, C. A. M.
    Frias, N. C.
    Baccarelli, D. C.
    Zoppa, A. L. V.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2017, 69 (04) : 807 - 814
  • [39] Comparison of dural closure alternatives: an experimental study
    Kizmazoglu, Ceren
    Ozyoruk, Safak
    Husemoglu, Resit Bugra
    Kalemci, Orhan
    Sozer, Gulden
    Sade, Burak
    BRITISH JOURNAL OF NEUROSURGERY, 2019, 33 (06) : 655 - 658
  • [40] Suturing technique and the integrity of dural closures: An in vitro study
    Megyesi, JF
    Ranger, A
    MacDonald, W
    Del Maestro, RF
    NEUROSURGERY, 2004, 55 (04) : 950 - 954