Study of dural suture watertightness: an in vitro comparison of different sealants

被引:41
|
作者
Chauvet, Dorian [1 ,2 ]
Viet Tran [3 ]
Mutlu, Gurkan
George, Bernard [1 ,2 ]
Allain, Jean-Marc [3 ]
机构
[1] Grp Hosp Pitie Salpetriere, Dept Neurosurg, F-75014 Paris, France
[2] Lariboisiere Hosp, F-75014 Paris, France
[3] Ecole Polytech, Lab Solids Mech, Palaiseau, France
关键词
Cerebrospinal fluid leakage; Dural suture; In vitro study; Sealants; CEREBROSPINAL-FLUID LEAKS; HYDROGEL SEALANT; COLLAGEN FLEECE; FIBRIN GLUE; REPAIR; BIOGLUE(R); PREVENTION; ADHESIVE; CLOSURES; DUROTOMY;
D O I
10.1007/s00701-011-1197-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
CSF leakages constitute a major complication of intradural procedures, especially for posterior fossa and skull base surgery. Dural suture watertightness is a decisive issue, and neurosurgeons routinely use different products to reinforce their dural closure. We have designed an experimental system capable of testing CSF leak pressure levels in order to compare two types of sutures in vitro and particularly four different sealants. Twenty-five fresh human cadaveric dural samples were removed and prepared for testing in a pressure chamber system connected to a hydraulic pressure motor. CSF leak levels were objectively registered. First, simple interrupted stitches were compared to running simple closure on 50-mm linear suture. Secondly, four sealants (two sealants/glues, BioglueA (R), DurasealA (R); two haemostatics, TachosilA (R), TissucolA (R)) were tested. Statistical analysis was performed with paired Student's t-test. No significant difference between interrupted closure and running suture was observed (p = 0.079). All sealants increased the watertightness of the suture significatively. However, comparison of the means of the differences for each product revealed large variations. In the conditions of our experiment, one sealant (DurasealA (R)) and one haemostatic (TachosilA (R)) seemed to show better results. We observed two different types of leakage: at the dura-sealant interface and through the sealant itself. We have developed an experimental device capable of testing dural closure watertightness. Interrupted stitch suturing seemed no different from running simple closure. On the contrary, the sealants tested show different watertightness capacities.
引用
收藏
页码:2465 / 2472
页数:8
相关论文
共 50 条
  • [1] Study of dural suture watertightness: an in vitro comparison of different sealants
    Dorian Chauvet
    Viet Tran
    Gurkan Mutlu
    Bernard George
    Jean-Marc Allain
    Acta Neurochirurgica, 2011, 153 : 2465 - 2472
  • [2] Usefulness of Sealants for Dural Closure: Evaluation in an In Vitro Model
    van Doormaal, Tristan
    Kinaci, Ahmet
    van Thoor, Sander
    Redegeld, Saskia
    Bergmann, Wilhelmina
    van der Zwan, Albert
    OPERATIVE NEUROSURGERY, 2018, 15 (04) : 425 - 431
  • [3] Comparison of Microleakage of Two Materials Used as Fissure Sealants with Different Methods: An In vitro Study
    Tehrani, Maryam Hajenoruzali
    Birjandi, Neda
    Nasr, Ehsan
    Shahtusi, Mina
    INTERNATIONAL JOURNAL OF PREVENTIVE MEDICINE, 2014, 5 (02) : 171 - 175
  • [4] Effect of Bonding Agent on Retention of Different Sealants: An in Vitro Study
    Attar, Moaz H.
    Abdallah, Medhat A.
    Alharthy, Hussein A.
    El Meligy, Omar A.
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2021, 45 (03) : 177 - 185
  • [5] The effects of barbed suture on watertightness after knee arthrotomy closure: a cadaveric study
    Kobayashi, Shu
    Niki, Yasuo
    Harato, Kengo
    Udagawa, Kazuhiko
    Matsumoto, Morio
    Nakamura, Masaya
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [6] The effects of barbed suture on watertightness after knee arthrotomy closure: a cadaveric study
    Shu Kobayashi
    Yasuo Niki
    Kengo Harato
    Kazuhiko Udagawa
    Morio Matsumoto
    Masaya Nakamura
    Journal of Orthopaedic Surgery and Research, 13
  • [7] Comparison of Different Suture Techniques
    Kavalci, Cemil
    Cevik, Yunsur
    Durukan, Polat
    Sayhan, Mustafa Burak
    JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2015, 6 (01) : 15 - 17
  • [8] Comparison between tensile characteristics of various suture materials with two suture techniques: an in vitro study
    Taysi, Aysegul Erten
    Ercal, Pinar
    Sismanoglu, Soner
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (11) : 6393 - 6401
  • [9] Comparison between tensile characteristics of various suture materials with two suture techniques: an in vitro study
    Aysegul Erten Taysi
    Pinar Ercal
    Soner Sismanoglu
    Clinical Oral Investigations, 2021, 25 : 6393 - 6401
  • [10] A comparison of fibrin sealants in relation to their in vitro and in vivo properties
    Dickneite, G
    Metzner, H
    Pfeifer, T
    Kroez, M
    Witzke, G
    THROMBOSIS RESEARCH, 2003, 112 (1-2) : 73 - 82