Tensile and shear behavior of box connector for precast concrete shear walls

被引:9
|
作者
Zhou, Yun [1 ,2 ,3 ]
Zhang, Baozheng [2 ]
Hwang, Hyeon-Jong [4 ]
Xi, Shuhang
Fang, Liang [2 ,5 ]
Huang, Yuan [1 ,2 ]
Yi, Weijian [1 ,2 ]
机构
[1] Hunan Univ, Key Lab Damage Diag Engn Struct Hunan Prov, Changsha 410082, Peoples R China
[2] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[3] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha 410082, Peoples R China
[4] Konkuk Univ, Sch Architecture, Seoul 05029, South Korea
[5] Hunan Agr Univ, Coll Water Resource & Civil Engn, Changsha 410128, Peoples R China
基金
中国国家自然科学基金; 新加坡国家研究基金会;
关键词
Precast concrete; Shear wall; Pull-out test; Shear test; Shear friction; Dowel action; Finite Element analysis; Box connector; PLASTIC-DAMAGE MODEL; BOND STRENGTH; SEISMIC PERFORMANCE; SPLICE; SLEEVE;
D O I
10.1016/j.engstruct.2021.112983
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As precast concrete (PC) shear walls have been widely used in housing industrialization, reliable connections are important to ensure structural integrity of prefabricated shear walls. In the present study, a pair of innovative steel sleeve and box connections were proposed for rapid installation of fully assembled PC shear walls. Pull-out tests were performed on six PC specimens with sleeve and box connectors. Further, monotonic and cyclic lateral loading tests were performed on eight PC wall-ground beam joints. The test parameters were the configuration of connectors in the pull-out tests, and screw bolt strength, axial compression ratio (ACR), and loading type in the lateral loading tests. The test results showed that early pull-out failure occurred in the embedded sleeve due to flexural deformation of the horizontal pin rod, while fracture of the screw bolt occurred in the box component. Shear strength of the wall joint was developed by adhesive/interlock action, dowel action, and shear friction action. As screw bolt strength and ACR increased, the shear strength increased. To investigate the characteristic failure behavior of the connector and wall joint specimens, nonlinear finite element analysis (FEA) was conducted using ABAQUS program. A parametric study was performed to investigate the effect of design parameters on the pull-out and shear strength of the wall joint. Further, the test results were compared with the current design code requirements. Finally, an improved connection was suggested to increase the structural performance of the wall joint.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] An Energy Dissipating Seismic Connector for Precast Concrete Shear Walls
    Aljuboori, Mohammed
    Tabatabai, Habib
    BUILDINGS, 2022, 12 (07)
  • [2] Flexural Behavior of Precast Lightweight Concrete Shear Walls
    Yang, Keun-Hyeok
    Mun, Ju-Hyun
    Oh, Na-Kyung
    ACI STRUCTURAL JOURNAL, 2023, 120 (02) : 217 - 231
  • [3] Cyclic Behavior of Multiple Hardening Precast Concrete Shear Walls
    Jiang, Hongbo
    Sun, Jian
    Qiu, Hongxing
    Cao, Dafu
    Ge, Wenjie
    Fang, Qiang
    Cui, Hengwei
    Chen, Kongyang
    BUILDINGS, 2022, 12 (12)
  • [4] The effect of precast concrete planks on shear connector strength
    Moy, SSJ
    Tayler, C
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1996, 36 (03) : 201 - 213
  • [5] SEISMIC RESISTANCE OF PRECAST CONCRETE SHEAR WALLS
    CACCESE, V
    HARRIS, HG
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1987, 15 (06): : 661 - 677
  • [6] Experimental study on seismic behavior of precast concrete hollow shear walls
    Han W.
    Qian J.
    Zhang W.
    Zhao Z.
    Zhang Y.
    Ma T.
    Zhang Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (02): : 32 - 41
  • [7] Self-centering behavior of unbonded precast concrete shear walls
    Erkmen, B.
    Schultz, A. E.
    EARTHQUAKE RESISTANT ENGINEERING STRUCTURES VI, 2007, 93 : 185 - +
  • [8] Shear behavior of reinforced concrete shear walls under tensile axial force with eccentricity
    Mizoguchi, Mitsuo
    Arai, Yasuyuki
    Kuchiji, Hideki
    Transactions of the Japan Concrete Institute, 2000, 22 : 369 - 376
  • [9] Behavior of steel-concrete composite bolted connector in precast reinforced concrete shear wall
    Jiang, Hongbo
    Qiu, Hongxing
    Sun, Jian
    Yang, Yuan
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (12) : 2572 - 2582
  • [10] Development of a Skewed Pipe Shear Connector for Precast Concrete Structures
    Kim, Sang-Hyo
    Choi, Jae-Gu
    Park, Sejun
    Lee, Hyunmin
    Heo, Won-Ho
    MATERIALS, 2017, 10 (05):