Development of a Skewed Pipe Shear Connector for Precast Concrete Structures

被引:0
|
作者
Kim, Sang-Hyo [1 ]
Choi, Jae-Gu [1 ]
Park, Sejun [1 ]
Lee, Hyunmin [2 ]
Heo, Won-Ho [1 ]
机构
[1] Yonsei Univ, Sch Civil & Environm Engn, Seoul 03722, South Korea
[2] Korea Railrd Res Inst, Railrd Infrastruct Res Team, Gyeonggi Do 16105, South Korea
来源
MATERIALS | 2017年 / 10卷 / 05期
关键词
shear connector; skewed pipe shear connector; push-out test; pull-out test; finite element analysis; precast concrete structure; BRIDGES; PERFORMANCE; KEYS;
D O I
10.3390/ma10050531
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Joint connection methods, such as shear key and loop bar, improve the structural performance of precast concrete structures; consequently, there is usually decreased workability or constructional efficiency. This paper proposes a high-efficiency skewed pipe shear connector. To resist shear and pull-out forces, the proposed connectors are placed diagonally between precast concrete segments and a cast-in-place concrete joint part on a girder. Design variables (such as the pipe diameter, length, and insertion angle) have been examined to investigate the connection performance of the proposed connector. The results of our testing indicate that the skewed pipe shear connectors have 50% higher ductility and a 15% higher ratio of maximum load to yield strength as compared to the corresponding parameters of the loop bar. Finite element analysis was used for validation. The resulting validation indicates that, compared to the loop bar, the skewed pipe shear connector has a higher ultimate shear and pull-out resistance. These results indicate that the skewed pipe shear connector demonstrates more idealized behavior than the loop bar in precast concrete structures.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] The effect of precast concrete planks on shear connector strength
    Moy, SSJ
    Tayler, C
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1996, 36 (03) : 201 - 213
  • [2] Tensile and shear behavior of box connector for precast concrete shear walls
    Zhou, Yun
    Zhang, Baozheng
    Hwang, Hyeon-Jong
    Xi, Shuhang
    Fang, Liang
    Huang, Yuan
    Yi, Weijian
    ENGINEERING STRUCTURES, 2021, 245
  • [3] An Energy Dissipating Seismic Connector for Precast Concrete Shear Walls
    Aljuboori, Mohammed
    Tabatabai, Habib
    BUILDINGS, 2022, 12 (07)
  • [4] A Type III grouted seismic connector for precast concrete structures
    Aragon, Theresa C.
    Kurama, Yahya C.
    Meinheit, Donald F.
    PCI JOURNAL, 2017, : 75 - 88
  • [5] Behavior of steel-concrete composite bolted connector in precast reinforced concrete shear wall
    Jiang, Hongbo
    Qiu, Hongxing
    Sun, Jian
    Yang, Yuan
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (12) : 2572 - 2582
  • [6] Development of diaphragm connector elements for three-dimensional nonlinear dynamic analysis of precast concrete structures
    Zhang, Dichuan
    Fleischman, Robert
    Naito, Clay J.
    Zhang, Zhi
    ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (02) : 187 - 202
  • [7] A new shear connector for wood-concrete composite structures
    Mungwa, MS
    Jullien, JF
    Foudjet, A
    Hentges, G
    5TH WORLD CONFERENCE ON TIMBER ENGINEERING, VOL 1, PROCEEDINGS, 1998, : 518 - 525
  • [8] Precast concrete pipe coupling
    Mehl, Robert
    Betonwerk und Fertigteil-Technik/Concrete Plant and Precast Technology, 2020, 86 (06): : 40 - 43
  • [9] State of the art of studies on precast concrete shear wall structures
    Xue W.
    Hu X.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (02): : 44 - 55
  • [10] Optimization of Shear Resistance in Precast Concrete Sandwich Wall Panels Using an S-Type Shear Connector
    Tawil, Herman
    Tan, Chee Ghuan
    Sulong, Nor Hafizah Ramli
    Nazri, Fadzli Mohamed
    Shamsudin, Mohd Fazaulnizam
    Bunnori, Norazura Muhamad
    BUILDINGS, 2024, 14 (06)