Tensile and shear behavior of box connector for precast concrete shear walls

被引:9
|
作者
Zhou, Yun [1 ,2 ,3 ]
Zhang, Baozheng [2 ]
Hwang, Hyeon-Jong [4 ]
Xi, Shuhang
Fang, Liang [2 ,5 ]
Huang, Yuan [1 ,2 ]
Yi, Weijian [1 ,2 ]
机构
[1] Hunan Univ, Key Lab Damage Diag Engn Struct Hunan Prov, Changsha 410082, Peoples R China
[2] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[3] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha 410082, Peoples R China
[4] Konkuk Univ, Sch Architecture, Seoul 05029, South Korea
[5] Hunan Agr Univ, Coll Water Resource & Civil Engn, Changsha 410128, Peoples R China
基金
中国国家自然科学基金; 新加坡国家研究基金会;
关键词
Precast concrete; Shear wall; Pull-out test; Shear test; Shear friction; Dowel action; Finite Element analysis; Box connector; PLASTIC-DAMAGE MODEL; BOND STRENGTH; SEISMIC PERFORMANCE; SPLICE; SLEEVE;
D O I
10.1016/j.engstruct.2021.112983
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As precast concrete (PC) shear walls have been widely used in housing industrialization, reliable connections are important to ensure structural integrity of prefabricated shear walls. In the present study, a pair of innovative steel sleeve and box connections were proposed for rapid installation of fully assembled PC shear walls. Pull-out tests were performed on six PC specimens with sleeve and box connectors. Further, monotonic and cyclic lateral loading tests were performed on eight PC wall-ground beam joints. The test parameters were the configuration of connectors in the pull-out tests, and screw bolt strength, axial compression ratio (ACR), and loading type in the lateral loading tests. The test results showed that early pull-out failure occurred in the embedded sleeve due to flexural deformation of the horizontal pin rod, while fracture of the screw bolt occurred in the box component. Shear strength of the wall joint was developed by adhesive/interlock action, dowel action, and shear friction action. As screw bolt strength and ACR increased, the shear strength increased. To investigate the characteristic failure behavior of the connector and wall joint specimens, nonlinear finite element analysis (FEA) was conducted using ABAQUS program. A parametric study was performed to investigate the effect of design parameters on the pull-out and shear strength of the wall joint. Further, the test results were compared with the current design code requirements. Finally, an improved connection was suggested to increase the structural performance of the wall joint.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Shear behavior of reinforced concrete coupling beam in shear walls
    Fu, Qixin
    Luo, Muxin
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology, 1993, 21 (03):
  • [32] Fragility models of precast concrete shear walls with grouted sleeves
    Xie L.
    Li X.
    Li A.
    Yang C.
    Wang X.
    Qian Y.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2021, 51 (06): : 935 - 941
  • [33] Shear behavior of dry and epoxied joints in precast concrete segmental box girder bridges under direct shear loading
    Ahmed, Ghafur H.
    Aziz, Omar Q.
    ENGINEERING STRUCTURES, 2019, 182 : 89 - 100
  • [34] Shear behavior of a novel bearing-shear connector for prefabricated concrete decks
    Zou, Yang
    Qin, Fengjiang
    Zhou, Jianting
    Zheng, Zhichao
    Huang, Zulin
    Zhang, Zhongya
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 268
  • [35] Experimental Study On Shear Performance of Steel-Concrete Composite Bolted Connectors in Precast Concrete Shear Walls
    Fang, Qiang
    Qiu, Hongxing
    Sun, Jian
    Jiang, Hongbo
    Yang, Yuan
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2022, 20 (04) : 445 - 459
  • [36] Shear Behavior of Hollow Concrete Block Masonry with Precast Concrete Anti-Shear Blocks
    Yang, Xinlei
    Wu, Hanchen
    Zhang, Jianxin
    Wang, Hailiang
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2019, 2019
  • [37] Lateral hysteretic behavior of precast concrete shear walls with unjointed vertical distribution bars and opening
    Cai, Qi
    Song, Xiaobin
    Xiao, Xuwen
    Gu, Xianglin
    ENGINEERING STRUCTURES, 2024, 305
  • [38] Self-Centering Behavior of Unbonded, Post-Tensioned Precast Concrete Shear Walls
    Erkmen, Bulent
    Schultz, Arturo E.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2009, 13 (07) : 1047 - 1064
  • [39] Experimental evaluation on the seismic behavior of precast concrete shear walls with slip-friction devices
    Fang, Qiang
    Sun, Jian
    Qiu, Hongxing
    Jiang, Hongbo
    Dal Lago, Bruno
    Biondini, Fabio
    JOURNAL OF BUILDING ENGINEERING, 2022, 52
  • [40] Experimental study on mechanical behavior of precast concrete shear walls with mortise-tenon joints
    Chu M.
    Wang B.
    Liu J.
    Zhang P.
    Li X.
    An N.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (07): : 173 - 182and222