Tissue-equivalent proportional counters in a high-energy neutron field at CERN

被引:2
|
作者
Lim, T
BottollierDepois, JF
Festag, JG
Golnik, H
Grillmaier, RE
Hofert, M
Lindborg, L
机构
关键词
D O I
10.1117/12.267920
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Within the framework of a research program of the Commission of European Communities (CEC) the reference radiation facility at CERN provided recently a mixed high-energy radiation field simulating the one found at civil aviation altitudes of about 10 km. In order to calibrate radiation detectors and to investigate their response to high-energy neutrons a series of measurements using five different instruments equipped with Low Pressure Tissue-Equivalent Proportional Counter (TEPC) and one Recombination Chamber (REM-2) has been carried out. The reference radiation field at CERN was produced by reactions of a primary beam mixed of 2/3 protons and 1/3 pions with a copper target and moderated by a concrete shielding. The paper summarises the results obtained with the five TEPC instruments and the REM-2, and discusses their characteristics.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 50 条
  • [31] Performance of a cylindrical tissue-equivalent proportional counter for use in neutron monitoring
    Chau, Q
    Lahaye, T
    Ménard, S
    Donadille, L
    Bolognese, T
    Rannou, A
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 297 - 300
  • [32] HIGH-ENERGY LIMITATIONS IN NEUTRON SPECTROMETRY WITH PROTON-RECOIL PROPORTIONAL COUNTERS
    YULE, TJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1970, 13 (01): : 269 - &
  • [33] Numerical modeling of the gas gain of low-pressure Tissue-Equivalent Proportional Counters
    Mazzucconi, D.
    Bortot, D.
    Pola, A.
    Agosteo, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 983
  • [34] IMPROVING A MULTICELLULAR TISSUE-EQUIVALENT PROPORTIONAL COUNTER FOR PERSONAL NEUTRON DOSIMETRY
    BORDY, JM
    BARTHE, J
    LAHAYE, T
    BOUTRUCHE, B
    SEGUR, P
    RADIATION PROTECTION DOSIMETRY, 1995, 61 (1-3) : 175 - 178
  • [35] A NEW CONCEPT OF A HIGH-SENSITIVITY TISSUE-EQUIVALENT PROPORTIONAL COUNTER FOR INDIVIDUAL NEUTRON DOSIMETRY
    BOUTRUCHE, B
    BORDY, JM
    BARTHE, J
    SEGUR, P
    PORTAL, G
    RADIATION PROTECTION DOSIMETRY, 1994, 52 (1-4) : 335 - 338
  • [36] Estimation of neutron quality factor using tissue equivalent proportional counters
    Borak, T.B.
    Stinchcomb, T.G.
    Proceedings of the International Congress of Radiation Research, 1984, : 1 - 04
  • [37] NEUTRON DOSE AND QUALITY FACTOR DETERMINATIONS WITH TISSUE EQUIVALENT PROPORTIONAL COUNTERS
    BRACKENBUSH, LW
    FAUST, LG
    HEALTH PHYSICS, 1973, 25 (03): : 304 - 304
  • [38] Microdosimetry studies at the BMRR and the MITR-II using miniature tissue-equivalent proportional counters
    Burmeister, J
    Kota, C
    Maughan, RL
    Riley, K
    Harling, O
    Wielopolski, L
    Ma, R
    Coderre, J
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 581 - 586
  • [39] ON THE CALIBRATION OF TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS WITH BUILT-IN ALPHA-PARTICLE SOURCES
    SCHREWE, UJ
    BREDE, HJ
    PIHET, P
    MENZEL, HG
    RADIATION PROTECTION DOSIMETRY, 1988, 23 (1-4) : 249 - 252
  • [40] SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER WITH COAXIAL ELECTRIC-FIELD
    BELONOGII, PN
    DROBCHENKO, EA
    KHARLAMOV, AD
    MEASUREMENT TECHNIQUES, 1985, 28 (10) : 901 - 903