Tissue-equivalent proportional counters in a high-energy neutron field at CERN

被引:2
|
作者
Lim, T
BottollierDepois, JF
Festag, JG
Golnik, H
Grillmaier, RE
Hofert, M
Lindborg, L
机构
关键词
D O I
10.1117/12.267920
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Within the framework of a research program of the Commission of European Communities (CEC) the reference radiation facility at CERN provided recently a mixed high-energy radiation field simulating the one found at civil aviation altitudes of about 10 km. In order to calibrate radiation detectors and to investigate their response to high-energy neutrons a series of measurements using five different instruments equipped with Low Pressure Tissue-Equivalent Proportional Counter (TEPC) and one Recombination Chamber (REM-2) has been carried out. The reference radiation field at CERN was produced by reactions of a primary beam mixed of 2/3 protons and 1/3 pions with a copper target and moderated by a concrete shielding. The paper summarises the results obtained with the five TEPC instruments and the REM-2, and discusses their characteristics.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 50 条
  • [21] EXPERIMENTAL-STUDY OF THE DOSE EQUIVALENT RESPONSE OF TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS TO LOW-ENERGY NEUTRONS
    ALBERTS, WG
    BUHLER, G
    DUDLER, R
    MENZEL, HG
    SCHUHMACHER, H
    RADIATION PROTECTION DOSIMETRY, 1984, 9 (03) : 211 - 214
  • [22] DOSE EQUIVALENT DETERMINED BY TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS IN THE ENVIRONMENT OF THE NEUTRON THERAPY FACILITY AT LOUVAIN-LA-NEUVE
    PIHET, P
    MEULDERS, JP
    MARQUEBREUCQ, S
    MENZEL, HG
    WAMBERSIE, A
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (711): : 311 - 311
  • [23] CALIBRATION OF TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS USED AS RADIATION PROTECTION DOSIMETERS
    DIETZE, G
    MENZEL, HG
    BUHLER, G
    RADIATION PROTECTION DOSIMETRY, 1984, 9 (03) : 245 - 249
  • [24] BNCT dosimetry performed with a mini twin tissue-equivalent proportional counters (TEPC)
    Moro, D.
    Colautti, P.
    Lollo, M.
    Esposito, J.
    Conte, V.
    De Nardo, L.
    Ferretti, A.
    Ceballos, C.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S171 - S174
  • [25] CALIBRATING AND TESTING TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS WITH AR-37
    ANACHKOVA, E
    KELLERER, AM
    ROOS, H
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1994, 33 (04) : 353 - 364
  • [26] Comparison of a tissue equivalent and a silicon equivalent proportional counter microdosimeter to high-energy proton and neutron fields
    Gersey, B.
    Aghara, S.
    Wilkins, R.
    Wedeking, J.
    Dwivedi, R. C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (06) : 2276 - 2281
  • [27] PERFORMANCE OF A NEUTRON DOSIMETER BASED ON A TISSUE-EQUIVALENT PROPORTIONAL CHAMBER
    EISEN, Y
    BRAKE, R
    VASILIK, D
    ERKKILA, B
    LITTLEJOHN, G
    HEALTH PHYSICS, 1984, 47 (01): : 171 - 171
  • [28] STUDY OF DOSE COMPOSITION IN TISSUE-EQUIVALENT PHANTOMS FOR HIGH-ENERGY PROTONS
    DUDKIN, VE
    SMIRENNY, LN
    YAKOVLEV, RM
    KOVALEV, EE
    HEALTH PHYSICS, 1972, 23 (05): : 663 - +