The dose response of normoxic polymer gel dosimeters measured using X-ray CT

被引:55
|
作者
Hill, B
Venning, A
Baldock, C
机构
[1] Canberra Hosp, Biomed Engn Serv, Med Phys Sect, Woden, ACT 2606, Australia
[2] Queensland Univ Technol, Sch Phys & Chem Sci, Brisbane, Qld, Australia
[3] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW 2006, Australia
来源
BRITISH JOURNAL OF RADIOLOGY | 2005年 / 78卷 / 931期
关键词
D O I
10.1259/bjr/46029447
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray CT was used to determine the dose response of normoxic polymer gel dosimeters. Normoxic polymer gel dosimeters were manufactured and irradiated up to 150 Gy. Up to 50 CT images were acquired oil a Toshiba Aquilion Multislice CT scanner using protocols for 80 kV and 135 kV to determine dose response. HU-dose sensitivity, the linear regression of data for the HU versus dose for the linear part of the curve LIP to 60 Gy was 0.38 +/- 0.07 HU Gy(-1) for 135 kV and 0.37 +/- 0.01 H U Gy(-1) for 80 kV. Dose resolution was found to be < 1.3 Gy for all absorbed dose range up to 70 Gy for 135 kV, similar to that measured previously for polyacrylamide gel (PAG). Although the HU-dose sensitivity was lower than that previously measured for PAG gel dosimeters it had a greater range of absorbed dose indicating that normoxic polymer gel dosimeters have potential in CT gel dosimetry.
引用
收藏
页码:623 / 630
页数:8
相关论文
共 50 条
  • [41] Introduction of a deformable x-ray CT polymer gel dosimetry system
    Maynard, Evan
    Heath, Emily
    Hilts, Michelle
    Jirasek, Andrew
    MEDICAL PHYSICS, 2017, 44 (08) : 4371 - 4371
  • [42] Study on energy dependence of PAGAT polymer gel dosimeter evaluated using X-Ray CT
    Sellakumar, P.
    Samuel, E. James Jebaseelan
    RADIATION MEASUREMENTS, 2010, 45 (01) : 92 - 97
  • [43] Dosimetry study of diagnostic X-ray using doped iodide normoxic polymer gels
    Huang, Y. R.
    Chang, Y. J.
    Hsieh, L. L.
    Liu, M. H.
    Liu, J. S.
    Chu, C. H.
    Hsieh, B. T.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 414 - 419
  • [44] Improving the quality of reconstructed X-ray CT images of polymer gel dosimeters: zero-scan coupled with adaptive mean filtering
    M. B. Kakakhel
    A. Jirasek
    H. Johnston
    T. Kairn
    J. V. Trapp
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 159 - 165
  • [45] Improving the quality of reconstructed X-ray CT images of polymer gel dosimeters: zero-scan coupled with adaptive mean filtering
    Kakakhel, M. B.
    Jirasek, A.
    Johnston, H.
    Kairn, T.
    Trapp, J. V.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 159 - 165
  • [46] Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters
    De Deene, Y
    Venning, A
    Hurley, C
    Healy, BJ
    Baldock, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (14): : 2459 - 2470
  • [47] Investigation of vacuum pumping on the dose response of the MAGAS normoxic polymer gel dosimeter
    Venning A.J.
    Mather M.L.
    Baldock C.
    Australasian Physics & Engineering Sciences in Medicine, 2005, 28 (2): : 105 - 110
  • [48] Response modification in polymer gel dosimeters
    Maryanski, M
    MEDICAL PHYSICS, 2002, 29 (06) : 1209 - 1209
  • [49] Absorbed dose determination in kilovoltage X-ray synchrotron radiation using alanine dosimeters
    D. J. Butler
    J. E. Lye
    T. E. Wright
    D. Crossley
    P. H. G. Sharpe
    A. W. Stevenson
    J. Livingstone
    J. C. Crosbie
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 943 - 950
  • [50] Absorbed dose determination in kilovoltage X-ray synchrotron radiation using alanine dosimeters
    Butler, D. J.
    Lye, J. E.
    Wright, T. E.
    Crossley, D.
    Sharpe, P. H. G.
    Stevenson, A. W.
    Livingstone, J.
    Crosbie, J. C.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (04) : 943 - 950