Biomechanical Evaluation of a Novel Loop Retention Mechanism for Cortical Graft Fixation in ACL Reconstruction

被引:3
|
作者
Gotschi, Tobias [1 ,2 ,3 ]
Rosenberg, George [1 ,2 ]
Li, Xiang [1 ,2 ]
Zhang, Chen [1 ,2 ,4 ]
Bachmann, Elias [1 ,2 ,3 ]
Snedeker, Jess G. [1 ,2 ,3 ]
Fucentese, Sandro F. [1 ,3 ]
机构
[1] Balgrist Univ Hosp, Forchstr 340, CH-8008 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomech, Zurich, Switzerland
[3] Balgrist Univ Hosp, Dept Orthoped, Zurich, Switzerland
[4] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Orthoped, Xian, Peoples R China
关键词
ACL reconstruction; cortical fixation; adjustable button; biomechanical testing; cyclic loading; ANTERIOR CRUCIATE LIGAMENT; ADJUSTABLE-LENGTH LOOP; IMPROVE SUTURE PULLOUT; SUSPENSION DEVICES; FIXED-LOOP; TENDON; FORCES; TUNNEL; MODEL; KNEE;
D O I
10.1177/2325967120904322
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Implant fixation by means of a cortical fixation device (CFD) has become a routine procedure in anterior cruciate ligament reconstruction. There is no clear consensus whether adjustable-length CFDs are more susceptible to loop lengthening when compared with pretied fixed-length CFDs. Purpose: To assess biomechanical performance measures of 3 types of CFDs when subjected to various loading protocols. Study Design: Controlled laboratory study. Methods: Three types of CFDs underwent biomechanical testing: 1 fixed length and 2 adjustable length. One of the adjustable-length devices is based on the so-called finger trap mechanism, and the other is based on a modified sling lock mechanism. A device-only test of 5000 cycles (n = 8 per group) and a tendon-device test of 1000 cycles (n = 8 per group) with lower and upper force limits of 50 and 250 N, respectively, were applied, followed by ramp-to-failure testing. Adjustable-length devices then underwent further cyclic testing with complete loop unloading (n = 5 per group) at each cycle, as well as fatigue testing (n = 3 per group) over a total of 1 million cycles. Derived mechanical parameters were compared among the devices for statistical significance using Kruskal-Wallis analysis of variance followed by post hoc Mann-Whitney U testing with Bonferroni correction. Results: All CFDs showed elongation <2 mm after 5000 cycles when tested in an isolated manner and withstood ultimate tensile forces in excess of estimated peak in vivo forces. In both device-only and tendon-device tests, differences in cyclic performance were found among the devices, favoring adjustable-length fixation devices over the fixed-length device. Completely unloading the suspension loops, however, led to excessive loop lengthening of the finger trap device, whereas the modified sling lock device remained stable throughout the test. The fixed-length device displayed superior ultimate strength over both adjustable-length devices. Both adjustable-length devices showed adequate fatigue behavior during high-cyclic testing. Conclusion: All tested devices successfully prevented critical construct elongation when tested with constant tension and withstood ultimate loads in excess of estimated in vivo forces during the rehabilitation phase. The finger trap device gradually lengthened excessively when completely unloaded during cyclic testing.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Biomechanical Considerations for Graft Fixation in ACL Reconstruction
    Ettinger, Max
    Petri, Max
    Kwisda, Sebastian
    Krettek, Christian
    Jagodzinski, Michael
    TECHNIQUES IN ORTHOPAEDICS, 2013, 28 (02) : 126 - 132
  • [2] Biomechanical evaluation of an allograft fixation system for ACL reconstruction
    Benca, Emir
    van Knegsel, Kenneth P. P.
    Zderic, Ivan
    Caspar, Jan
    Strassl, Andreas
    Hirtler, Lena
    Fuchssteiner, Christoph
    Gueorguiev, Boyko
    Windhager, Reinhard
    Widhalm, Harald
    Varga, Peter
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [3] The Bone Bridge for Tibial ACL Graft Fixation: A Biomechanical Analysis of Different Tibial Fixation Methods for ACL Reconstruction
    Peez, Christian
    Gressmann, Marvin
    Raschke, Michael J.
    Glasbrenner, Johannes
    Briese, Thorben
    Frank, Andre
    Herbst, Elmar
    Kittl, Christoph
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (01)
  • [4] BIOMECHANICAL PERFORMANCE OF METALLIC AND BIOABSORBABLE INTERFERENCE SCREW FOR TIBIAL GRAFT FIXATION IN ACL RECONSTRUCTION
    Ocampo More, Ari Digiacomo
    Almeida Pizzolatti, Andre Luiz
    Fancello, Eduardo
    de Mello Roesler, Carlos Rodrigo
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [5] Comparison between a novel human cortical bone screw and bioabsorbable interference screw for graft fixation of ACL reconstruction
    Shen, X. -Z.
    Qu, F.
    Li, C. -B.
    Qi, W.
    Lu, X.
    Li, H. -L.
    Guo, Q.
    Wang, J. -T.
    Zhao, G.
    Liu, Y. -J.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2018, 22 : 111 - 118
  • [6] Biomechanical evaluation of press-fit femoral fixation technique in ACL reconstruction
    Attila Pavlik
    Péter Hidas
    Tibor Czigány
    István Berkes
    Knee Surgery, Sports Traumatology, Arthroscopy, 2004, 12 : 528 - 533
  • [7] Biomechanical evaluation of a bioabsorbable expansion bolt for hamstring graft fixation in ACL reconstruction: an experimental study in calf tibial bone
    Piltz, S
    Dieckmann, R
    Meyer, L
    Strunk, P
    Plitz, W
    Lob, G
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (09) : 577 - 584
  • [8] Biomechanical evaluation of a bioabsorbable expansion bolt for hamstring graft fixation in ACL reconstruction: an experimental study in calf tibial bone
    S. Piltz
    R. Dieckmann
    L. Meyer
    P. Strunk
    W. Plitz
    G. Lob
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 577 - 584
  • [9] Biomechanical evaluation of press-fit femoral fixation technique in ACL reconstruction
    Pavlik, A
    Hidas, P
    Czigány, T
    Berkes, I
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (06) : 528 - 533
  • [10] Biomechanical evaluation of six femur-graft-tibia complexes in ACL reconstruction
    Labianca, L.
    Monaco, E.
    Speranza, A.
    Camillieri, G.
    Ferretti, A.
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2006, 7 (03) : 131 - 135