Characterization of adrenal lesions using chemical shift MRI: Comparison between 1.5 tesla and two echo time pair selection at 3.0 tesla MRI

被引:16
|
作者
Nakamura, Shinichi [1 ]
Namimoto, Tomohiro [1 ]
Morita, Kosuke [1 ]
Utsunomiya, Daisuke [1 ]
Oda, Seitaro [1 ]
Nakaura, Takeshi [1 ]
Hirai, Toshinori [1 ]
Yamashita, Yasuyuki [1 ]
机构
[1] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto 8608556, Japan
关键词
chemical shift imaging; adrenal; gradient echo; IN-PHASE; MASSES; ADENOMAS; DIFFERENTIATION; DIAGNOSIS; BENIGN; CT;
D O I
10.1002/jmri.22728
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare chemical shift MRI obtained at 1.5 Tesla (T) and two pairs of echo time (TE) in-phase and opposed-phase 3.0T MRI to assess their usefulness for the differentiation between adrenal adenomas and non-adenomas. Materials and Methods: We evaluated 91 adrenal masses (75 adenomas, 16 non-adenomas) in 85 patients. The MR imaging parameters were: T1-dual-gradient-echo(GRE) [echo times (TEs) = 1.1/2.3 ms (first-echo-pair) or 3.5/4.6 ms (second-echo-pair)] at 3.0T, and T1-dual-GRE (TEs = 2.4/4.8 ms) at 1.5T. Scans were quantitatively assessed for the signal intensity (SI) index, calculated as [(SIin-phase-SIopposed-phase)/(SIin-phase)] x 100(%). To test for differences between adenomas and non-adenomas, we performed quantitative analysis and analysis of variance. Results: For all images, the SI index differed significantly between adenomas and non-adenomas. The sensitivity / specificity of SI index at the first-echo-pair of 3.0T was 100%/ 100%, that of 95.6%/ 100% at the second-echo-pair of 3.0T, and 91.7%/ 88.9% at 1.5T, respectively. At intra-individual comparisons, the SI indices obtained with the second-echo-pair at 3.0T were significantly lower than on the first-echo-pair at 3.0T and 1.5T. Conclusion: Chemical shift MRI at 3.0T provides more accurate differentiation between adenomas and non-adenomas than at 1.5T. The SI index of the first-echo-pair at 3.0T is the most reliable evaluation method for differentiating adrenal adenomas from non-adenomas.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [21] Two-dimensional excitation short echo time chemical shift imaging at 0.5 Tesla
    Prost, RW
    Mark, LP
    Li, SJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (03) : 442 - 448
  • [22] Characterization of Adrenal Lesions at Chemical-Shift MRI: A Direct Intraindividual Comparison of In- and OpposedPhase Imaging at 1.5 T and 3 T
    Ream, Justin M.
    Gaing, Byron
    Mussi, Thais C.
    Rosenkrantz, Andrew B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : 536 - 541
  • [23] Comparison between 1.5 and 3-Tesla MRI findings in Ménière's disease
    Duarte, Juliana Antoniolli
    Garcia, Marcio Ricardo Taveira
    Souza, Soraia Ale
    Monsanto, Rafael da Costa
    Sarpi, Maira de Oliveira
    Juliano, Amy
    Gananca, Fernando Freitas
    FRONTIERS IN NEUROLOGY, 2024, 15
  • [24] Reproducibility of Intra- and Interscanner Measurements of Liver Fat Using Complex Confounder-corrected Chemical Shift Encoded MRI at 3.0 Tesla
    Wu, Bing
    Han, Wei
    Li, Zhenhong
    Zhao, Yonghua
    Ge, Mingmei
    Guo, Xueqing
    Wu, Xinhuai
    SCIENTIFIC REPORTS, 2016, 6
  • [25] Whole Body Sodium MRI at 0.5 Tesla Using Surface Coil and Long Echo Time Sequence
    N. V. Anisimov
    E. G. Sadykhov
    O. S. Pavlova
    D. V. Fomina
    A. A. Tarasova
    Yu. A. Pirogov
    Applied Magnetic Resonance, 2019, 50 : 1149 - 1161
  • [26] Whole Body Sodium MRI at 0.5 Tesla Using Surface Coil and Long Echo Time Sequence
    Anisimov, N., V
    Sadykhov, E. G.
    Pavlova, O. S.
    Fomina, D., V
    Tarasova, A. A.
    Pirogov, Yu A.
    APPLIED MAGNETIC RESONANCE, 2019, 50 (10) : 1149 - 1161
  • [27] Premature cystic lesions in shoulders of elite junior javelin and volleyball athletes: a comparative evaluation using 3.0 Tesla MRI
    Beitzel, Knut
    Beitzel, Kirsten I.
    Zandt, Julia F.
    Buchmann, Stefan
    Schwirtz, Ansgar
    Imhoff, Andreas B.
    Reiser, Maximilian
    Brucker, Peter U.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (06) : 792 - 799
  • [28] Cerebral vascular response to hypercapnia:: Determination with perfusion MRI at 1.5 and 3.0 tesla using a pulsed arterial spin labeling technique
    Noeth, Ulrike
    Meadows, Guy E.
    Kotajima, Futoshi
    Deichmann, Ralf
    Corfield, Douglas R.
    Turner, Robert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) : 1229 - 1235
  • [29] Assessment and comparison of image quality between two real-time sequences for dynamic MRI of distal joints at 3.0 Tesla (vol 64 , pg 1093 , 2023 )
    Garetier, M.
    Rousset, J.
    Makki, K.
    ACTA RADIOLOGICA, 2023, 64 (10) : 2686 - 2686
  • [30] Multicontrast black-blood MRI of carotid arteries: Comparison between 1.5 and 3 Tesla magnetic field strengths
    Yarnykh, VL
    Terashima, M
    Hayes, CE
    Shimakawa, A
    Takaya, N
    Nguyen, PK
    Brittain, JH
    McConnell, MV
    Yuan, C
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) : 691 - 698