Whole Body Sodium MRI at 0.5 Tesla Using Surface Coil and Long Echo Time Sequence

被引:0
|
作者
N. V. Anisimov
E. G. Sadykhov
O. S. Pavlova
D. V. Fomina
A. A. Tarasova
Yu. A. Pirogov
机构
[1] Lomonosov Moscow State University,Faculty of Fundamental Medicine
[2] Institute of Engineering Physics for Biomedicine,Faculty of Physics
[3] National Research Nuclear University “MEPhI”,undefined
[4] Lomonosov Moscow State University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Experiments on sodium (23Na) magnetic resonance imaging (MRI) of human organs, including the construction of whole body (WB) MRI, on a clinical 0.5-T scanner are described. The specificity of the research is their conduct in the presence of radio frequency (RF) interference, characterized by the frequency drift of the parasitic RF signal, which complicates its filtering. To solve this problem, the receiver bandwidth (BW) was set as narrow as possible, which, in turn, determined the low sampling rate and pulse sequence with relatively long echo time (TE)—12 ms, which is comparable to the transverse relaxation time of sodium nuclei. 23Na MRI on a 0.5-T clinical scanner was achieved without significant modifications in the hardware—only 20-cm square-shaped frame coil was made as a transceiver probe head. Scanning was performed using gradient echo method with in-plane resolution of (6.6 × 6.6) mm2 without slice selection. After processing the data in K-space, including exponential apodization, images were obtained in which human organs are represented with signal-to-noise ratio (SNR) up to several tens. The scans from nine individual segments of the human body in prone and supine positions were acquired to produce 23Na WB MRI. The time for one body segment scan was 30 min. The results of the work can be used to assess the potential capabilities of scanners of this class and to compare them with the data obtained using more advanced tools to assess their effectiveness.
引用
收藏
页码:1149 / 1161
页数:12
相关论文
共 50 条
  • [1] Whole Body Sodium MRI at 0.5 Tesla Using Surface Coil and Long Echo Time Sequence
    Anisimov, N., V
    Sadykhov, E. G.
    Pavlova, O. S.
    Fomina, D., V
    Tarasova, A. A.
    Pirogov, Yu A.
    APPLIED MAGNETIC RESONANCE, 2019, 50 (10) : 1149 - 1161
  • [2] Whole body sodium MRI at 3T using an asymmetric birdcage resonator and short echo time sequence: first images of a male volunteer
    Wetterling, Friedrich
    Corteville, Dominique M.
    Kalayciyan, Raffi
    Rennings, Andreas
    Konstandin, Simon
    Nagel, Armin M.
    Stark, Helmut
    Schad, Lothar R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (14): : 4555 - 4567
  • [3] Whole-body MRI using a sliding table and repositioning surface coil approach
    Taro Takahara
    Thomas Kwee
    Satoshi Kibune
    Reiji Ochiai
    Tetsuro Sakamoto
    Tetsu Niwa
    Marc Van Cauteren
    Peter Luijten
    European Radiology, 2010, 20 : 1366 - 1373
  • [4] Whole-body MRI using a sliding table and repositioning surface coil approach
    Takahara, Taro
    Kwee, Thomas
    Kibune, Satoshi
    Ochiai, Reiji
    Sakamoto, Tetsuro
    Niwa, Tetsu
    Van Cauteren, Marc
    Luijten, Peter
    EUROPEAN RADIOLOGY, 2010, 20 (06) : 1366 - 1373
  • [5] Three-Dimensional Ultrashort Echo Time Imaging of Solid Polymers on a 3-Tesla Whole-Body MRI Scanner
    Springer, Fabian
    Martirosian, Petros
    Schwenzer, Nina F.
    Szimtenings, Michael
    Kreisler, Peter
    Claussen, Claus D.
    Schick, Fritz
    INVESTIGATIVE RADIOLOGY, 2008, 43 (11) : 802 - 808
  • [6] Long echo time STIR sequence MRI of optic nerves in optic neuritis
    Onofrj, M
    Tartaro, A
    Thomas, A
    Gambi, D
    Fulgente, T
    Pizzi, CD
    Bonomo, L
    NEURORADIOLOGY, 1996, 38 (01) : 66 - 69
  • [7] Quality Comparison of 3 Tesla multiparametric MRI of the prostate using a flexible surface receiver coil versus conventional surface coil plus endorectal coil setup
    T. Ullrich
    M. D. Kohli
    M. A. Ohliger
    K. Magudia
    S. S. Arora
    T. Barrett
    L. K. Bittencourt
    D. J. Margolis
    L. Schimmöller
    B. Turkbey
    A. C. Westphalen
    Abdominal Radiology, 2020, 45 : 4260 - 4270
  • [8] Quality Comparison of 3 Tesla multiparametric MRI of the prostate using a flexible surface receiver coil versus conventional surface coil plus endorectal coil setup
    Ullrich, T.
    Kohli, M. D.
    Ohliger, M. A.
    Magudia, K.
    Arora, S. S.
    Barrett, T.
    Bittencourt, L. K.
    Margolis, D. J.
    Schimmoeller, L.
    Turkbey, B.
    Westphalen, A. C.
    ABDOMINAL RADIOLOGY, 2020, 45 (12) : 4260 - 4270
  • [9] Characterization of adrenal lesions using chemical shift MRI: Comparison between 1.5 tesla and two echo time pair selection at 3.0 tesla MRI
    Nakamura, Shinichi
    Namimoto, Tomohiro
    Morita, Kosuke
    Utsunomiya, Daisuke
    Oda, Seitaro
    Nakaura, Takeshi
    Hirai, Toshinori
    Yamashita, Yasuyuki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (01) : 95 - 102
  • [10] Whole body MRI at 7 tesla using a 1H/19F elliptic body coil with whole-body, fat-signal insensitive, three dimensional magnetic field shim algorithm
    Liebes, Leonard
    Lee, Ray
    Liu, Songtao
    Buckley, Michael T.
    Hochster, Howard
    Gonen, Oded
    MOLECULAR CANCER THERAPEUTICS, 2007, 6 (12) : 3479S - 3479S