A customizable aluminum compensator system for total body irradiation

被引:0
|
作者
Naessig, Madison [1 ,2 ]
Hernandez, Soleil [2 ]
Astorga, Nestor Rodrigo [1 ]
McCulloch, James [1 ]
Saenz, Daniel [1 ]
Myers, Pamela [1 ]
Rasmussen, Karl [1 ]
Stathakis, Sotirios [1 ]
Ha, Chul S. [1 ]
Papanikolaou, Niko [1 ]
Ford, John [2 ]
Kirby, Neil [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Radiat Oncol, 7979 Wurzbach Rd,MC 7889, San Antonio, TX 78229 USA
[2] Texas A&M Univ, Dept Nucl Engn, College Stn, TX 77843 USA
来源
关键词
compensator; dose homogeneity; total body irradiation; TOTAL MARROW IRRADIATION; INTERSTITIAL PNEUMONITIS; THERAPY;
D O I
10.1002/acm2.13393
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop a simplified aluminum compensator system for total body irradiation (TBI) that is easy to assemble and modify in a short period of time for customized patient treatments. Methods The compensator is composed of a combination of 0.3 cm thick aluminum bars, two aluminum T-tracks, spacers, and metal bolts. The system is mounted onto a plexiglass block tray. The design consists of 11 fixed sectors spanning from the patient's head to feet. The outermost sectors utilize 7.6 cm wide aluminum bars, while the remaining sectors use 2.5 cm wide aluminum bars. There is a magnification factor of 5 from the compensator to the patient treatment plane. Each bar of aluminum is interconnected at each adjacent sector with a tongue and groove arrangement and fastened to the T-track using a metal washer, bolt, and nut. Inter-bar leakage of the compensator was tested using a water tank and diode. End-to-end measurements were performed with an ion chamber in a solid water phantom and also with a RANDO phantom using internal and external optically stimulated luminescent detectors (OSLDs). In-vivo patient measurements from the first 20 patients treated with this aluminum compensator were compared to those from 20 patients treated with our previously used lead compensator system. Results The compensator assembly time was reduced to 20-30 min compared to the 2-4 h it would take with the previous lead design. All end-to-end measurements were within 10% of that expected. The median absolute in-vivo error for the aluminum compensator was 3.7%, with 93.8% of measurements being within 10% of that expected. The median error for the lead compensator system was 5.3%, with 85.1% being within 10% of that expected. Conclusion This design has become the standard compensator at our clinic. It allows for quick assembly and customization along with meeting the Task Group 29 recommendations for dose uniformity.
引用
收藏
页码:36 / 44
页数:9
相关论文
共 50 条
  • [21] RESPONSE TO TOTAL BODY IRRADIATION
    DOWDY, AH
    BENNETT, LR
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1955, 73 (04): : 639 - 648
  • [23] Development of 3D printed patient-specific compensator for total body irradiation based on CT images
    Kang, Sang-Won
    Song, Changhoon
    Kim, In Ah
    Kim, Jae-Sung
    Eeom, Keun-Yong
    Chung, Jin-Beom
    Lee, Boram
    Kang, Seonghee
    Cho, Woong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2023, 83 (03) : 216 - 225
  • [24] Total Body Irradiation (TBI) with Organ Sparing Utilizing Both Volumetric Modulated Arc Therapy (VMAT) and Electronic Compensator
    Luo, G.
    Osmundson, E. C.
    Ding, G. X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E496 - E497
  • [25] Total Body Irradiation with a Compensator Fabricated Using a 3D Optical Scanner and a 3D Printer
    Park, S.
    Choi, C.
    Chun, M.
    Kim, J.
    Han, J.
    Cho, J.
    Kim, Y.
    Park, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3150 - 3150
  • [26] Feasibility of Using the 'Irregular Surface Compensator' Planning Feature of the Eclipse TPS for Total Body Irradiation (TBI) Treatment Planning
    Ayan, A.
    Lu, L.
    Rong, Y.
    Cunningham, M.
    Weldon, M.
    Welliver, M.
    Woollard, J.
    Gupta, N.
    MEDICAL PHYSICS, 2012, 39 (06) : 3805 - 3805
  • [27] Development of 3D printed patient-specific compensator for total body irradiation based on CT images
    Sang-Won Kang
    Changhoon Song
    In Ah Kim
    Jae-Sung Kim
    Keun-Yong Eeom
    Jin-Beom Chung
    Boram Lee
    Seonghee Kang
    Woong Cho
    Journal of the Korean Physical Society, 2023, 83 : 216 - 225
  • [28] Total body irradiation with a compensator fabricated using a 3D optical scanner and a 3D printer
    Park, So-Yeon
    Kim, Jung-In
    Joo, Yoon Ha
    Lee, Jung Chan
    Park, Jong Min
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09): : 3735 - 3756
  • [29] CHANGES IN THE CARDIOVASCULAR SYSTEM FOLLOWING TOTAL BODY X-IRRADIATION
    CASTER, WO
    ARMSTRONG, WD
    SIMONSON, E
    AMERICAN JOURNAL OF PHYSIOLOGY, 1957, 188 (01): : 169 - 177
  • [30] EFFECT OF TOTAL BODY IRRADIATION ON WOUND HEALING AND HEMATOPOIETIC SYSTEM IN MICE
    ZELMAN, D
    SONG, IC
    PORTEOUS, DD
    BROMBERG, BE
    BULLETIN OF THE NEW YORK ACADEMY OF MEDICINE, 1969, 45 (03) : 293 - &