Characterization of a Compton camera setup with monolithic LaBr3(Ce) absorber and segmented GAGG scatter detectors

被引:0
|
作者
Liprandi, Silvia [1 ]
Takyu, Sodai [2 ,3 ]
Aldawood, Saad [1 ,4 ]
Binder, Tim [1 ]
Dedes, George [1 ]
Kamada, Kei [9 ]
Lutter, Rudolf [1 ]
Mayerhofer, Michael [1 ,5 ,6 ]
Miani, Agnese [1 ,7 ]
Mohammadi, Akram [2 ,3 ]
Nishikido, Fumihiko [2 ,3 ]
Schaart, Dennis R. [8 ]
Lozano, Ingrid I. Valencia [1 ]
Yoshida, Eiji [2 ,3 ]
Yamaya, Taiga [2 ,3 ]
Parodi, Katia [1 ]
Thirolf, Peter G. [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Med Phys, Munich, Germany
[2] Natl Inst Quantum, NIRS, Chiba, Japan
[3] Natl Inst Radiol Sci & Technol QST, NIRS, Chiba, Japan
[4] King Saud Univ, Dept Phys & Astron, Riyadh, Saudi Arabia
[5] Univ Bundeswehr, Dept Phys, Munich, Germany
[6] Univ Hamburg, Dept Phys, Hamburg, Germany
[7] Cambridge Med Robot Ltd, Cambridge, England
[8] Delft Univ Technol, Delft, Netherlands
[9] C&A Corp, Sendai, Miyagi, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of this study is to perform a first characterization and proof of principle investigation of a Compton camera setup composed by a scatterer component consisting of a pixelated GAGG crystal read out by a SiPM multi-pixel photon counter (MPPC) and an absorber component consisting of a monolithic LaBr3(Ce) scintillator read out by a 256-fold multianode photomultiplier (PMT). The rationale of the study is to develop a Compton camera system as a future ion beam range verification device during particle therapy, via prompt gamma imaging. The properties to be investigated are the reconstruction efficiency and accuracy achievable with this system for detecting prompt-gamma rays. The Compton camera system described has been tested with a laboratory radioactive Cesium 137 source, in a certain geometrical configuration. The readout system is based on individual spectroscopy (NIM+VME) electronic modules, digitizing energy and time signals. The data have been analyzed to produce an input for the image reconstruction, performed using the MEGAIib toolkit software.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Investigation on a small FoV gamma camera based on LaBr3:Ce continuous crystal
    Pani, R.
    Pellegrini, R.
    Bennati, P.
    Cinti, M. N.
    Vittorini, F.
    Scafe, R.
    Lo Meo, S.
    Navarria, F. L.
    Moschini, G.
    Cencelli, V. Orsolini
    De Notaristefani, F.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2009, 197 : 202 - 205
  • [32] Experimental assessments of the timing performances of detectors constructed with LaBr3, CeBr3, LFS, LSO, LYSO, GAGG scintillators
    Peng, Q.
    Xie, S.
    Sui, T.
    Yang, M.
    Huang, Q.
    Xu, J.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [33] Comparison of LaBr3 : Ce and LaCl3 : Ce with NaI(Tl) and Cadmium Zinc Telluride (CZT) detectors
    Alexiev, D.
    Mo, L.
    Prokopovich, D. A.
    Smith, M. L.
    Matuchova, M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 1174 - 1177
  • [34] Characterization of LaBr3: Ce and LaCl3: Ce scintillators for gamma-ray spectroscopy
    K. Alzimami
    E. Abuelhia
    Z. Podolyak
    A. Ioannou
    N. M. Spyrou
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 755 - 759
  • [35] γ-ray coincidence and fast-timing measurements using LaBr3(Ce) detectors and gammasphere
    Zhu, S.
    Kondev, F. G.
    Carpenter, M. P.
    Ahmad, I.
    Chiara, C. J.
    Greene, J. P.
    Gurdal, G.
    Janssens, R. V. F.
    Lalkovski, S.
    Lauritsen, T.
    Seweryniak, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 231 - 233
  • [36] Characterization of LaBr3: Ce and LaCl3: Ce scintillators for gamma-ray spectroscopy
    Alzimami, K.
    Abuelhia, E.
    Podolyak, Z.
    Ioannou, A.
    Spyrou, N. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 278 (03) : 755 - 759
  • [37] Response function and linearity for high energy γ-rays in large volume LaBr3:Ce detectors
    Gosta, G.
    Blasi, N.
    Camera, F.
    Million, B.
    Giaz, A.
    Wieland, O.
    Rossi, F. M.
    Utsunomiya, H.
    Ari-izumi, T.
    Takenaka, D.
    Filipescu, D.
    Gheorghe, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 879 : 92 - 100
  • [38] Unfolding of sparse high-energy γ-ray spectra from LaBr3:Ce detectors
    Soderstrom, P-A
    Capponi, L.
    Iancu, V
    Lattuada, D.
    Pappalardo, A.
    Turturica, G., V
    Aciksoz, E.
    Balabanski, D. L.
    Constantin, P.
    Guardo, G. L.
    Ilie, M.
    Ilie, S.
    Matei, C.
    Nichita, D.
    Petruse, T.
    Spataru, A.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (11)
  • [39] Development of a compact and high spatial resolution gamma camera system using LaBr3(Ce)
    Yamamoto, Seiichi
    Imaizumi, Masao
    Shimosegawa, Eku
    Hatazawa, Jun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01): : 261 - 269
  • [40] On the applicability of LaBr3 detectors in the non-destructive characterization of radioactive waste drums
    C. Göbbels
    T. Krings
    E. Mauerhofer
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 303 : 2399 - 2405