Unfolding of sparse high-energy γ-ray spectra from LaBr3:Ce detectors

被引:6
|
作者
Soderstrom, P-A [1 ]
Capponi, L. [1 ]
Iancu, V [1 ]
Lattuada, D. [1 ,2 ,3 ]
Pappalardo, A. [1 ]
Turturica, G., V [1 ,4 ]
Aciksoz, E. [1 ]
Balabanski, D. L. [1 ]
Constantin, P. [1 ]
Guardo, G. L. [1 ,3 ]
Ilie, M. [4 ,5 ]
Ilie, S. [1 ,4 ]
Matei, C. [1 ]
Nichita, D. [1 ,4 ]
Petruse, T. [1 ,4 ]
Spataru, A. [1 ,4 ]
机构
[1] Horia Hulubei Natl Inst R&D Phys & Nucl Engn IFIN, Extreme Light Infrastruct Nucl Phys ELI NP, Reactorului 30, Bucharest 077125, Romania
[2] Univ Enna Kore, I-94100 Enna, Italy
[3] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95125 Catania, Italy
[4] Univ Politehn Bucuresti, Splaiul Inepenentei 313, Bucharest 060042, Romania
[5] Horia Hulubei Natl Inst R&D Phys & Nucl Engn IFIN, Tandem Accelerators Dept DAT, Reactorului 30, Bucharest 077125, Romania
关键词
Analysis and statistical methods; Gamma detectors (scintillators; CZT; HPG; HgI etc); BEAM; SIMULATION;
D O I
10.1088/1748-0221/14/11/T11007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Here we report on the characterization of one of the large-volume LaBr3:Ce detectors for the ELIGANT project at ELI-NP. The main focus of this work is the response function for high-energy gamma rays of such detectors. In particular, we compare a selection of unfolding methods to resolve small structures in gamma-ray spectra with high-energies. Three methods have been compared using gamma-ray spectra with energies up to 12 MeV obtained in an experiment at the 3MV Tandetron (TM) facility at IFIN-HH. The results show that the iterative unfolding approach gives the best qualitative reproduction of the emitted gamma-ray spectrum. Furthermore, the correlation fluctuations in high-energy regime from the iterative method are two orders of magnitude smaller than when using the matrix inversion approach with second derivative regularization. In addition, the iterative method is computationally faster as it does not contain large matrix inversions. The matrix inversion method does, however, give more consistent results over the full energy range and in the low-statistics limit. Our conclusion is that the performance of the iterative approach makes it well suitable for semi-online analysis of experimental data. These results will be important, both for experiments with the ELIGANT setup, and for on-line diagnostics of the energy spread of the gamma-ray beam which is under implementation at ELI-NP.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Measurements of high-energy γ-rays with LaBr3 : Ce detectors
    Ciemala, M.
    Balabanski, D.
    Csatlos, M.
    Daugas, J. M.
    Georgiev, G.
    Gulyas, J.
    Kmiecik, M.
    Krasznahorkay, A.
    Lalkovski, S.
    Lefebvre-Schuhl, A.
    Lozeva, R.
    Maj, A.
    Vitez, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (01): : 76 - 79
  • [2] High count rate γ-ray spectroscopy with LaBr3:Ce scintillation detectors
    Loeher, B.
    Savran, D.
    Fiori, E.
    Miklavec, M.
    Pietralla, N.
    Vencelj, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 686 : 1 - 6
  • [3] High energy gamma-ray spectroscopy with LaBr3 scintillation detectors
    Quarati, F. G. A.
    Owens, Alan
    Dorenbos, P.
    de Haas, J. T. M.
    Benzoni, G.
    Blasi, N.
    Boiano, C.
    Brambilla, S.
    Camera, F.
    Alba, R.
    Bellia, G.
    Maiolino, C.
    Santonocito, D.
    Ahmed, M.
    Brown, N.
    Stave, S.
    Weller, H. R.
    Wu, Y. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 157 - 169
  • [4] High energy gamma-ray spectroscopy with LaBr3 scintillation detectors
    SRE-PA, ESA/ESTEC, Keplerlaan 1, 2200AG Noordwijk, Netherlands
    不详
    不详
    不详
    不详
    不详
    不详
    Nucl Instrum Methods Phys Res Sect A, 1 (157-169):
  • [5] Gain correction algorithm for LaBr3(Ce) detectors
    Lica, Razvan, 1600, Politechnica University of Bucharest (78):
  • [6] GAIN CORRECTION ALGORITHM FOR LaBr3(Ce) DETECTORS
    Lica, Razvan
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2016, 78 (03): : 264 - 269
  • [7] Digital processing of signals from LaBr3:Ce scintillation detectors
    Nakhostin, M.
    Podolyak, Zs
    Regan, P. H.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [8] Response function and linearity for high energy γ-rays in large volume LaBr3:Ce detectors
    Gosta, G.
    Blasi, N.
    Camera, F.
    Million, B.
    Giaz, A.
    Wieland, O.
    Rossi, F. M.
    Utsunomiya, H.
    Ari-izumi, T.
    Takenaka, D.
    Filipescu, D.
    Gheorghe, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 879 : 92 - 100
  • [9] The energy response of LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals for GECAM
    Feng, Pei-Yi
    Sun, Xi-Lei
    An, Zheng-Hua
    Deng, Yong
    Wang, Cheng-Er
    Jiang, Huang
    Li, Jun-Jie
    Zhang, Da-Li
    Li, Xin-Qiao
    Xiong, Shao-Lin
    Zheng, Chao
    Gong, Ke
    Yang, Sheng
    Liu, Xiao-Jing
    Gao, Min
    Wen, Xiang-Yang
    Liu, Ya-Qing
    Xu, Yan-Bing
    Zhao, Xiao-Yun
    Liu, Jia-Cong
    Zhang, Fan
    Lu, Hong
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (02)
  • [10] The energy response of LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals for GECAM
    Pei?Yi Feng
    Xi?Lei Sun
    Zheng?Hua An
    Yong Deng
    Cheng?Er Wang
    Huang Jiang
    Jun?Jie Li
    Da?Li Zhang
    Xin?Qiao Li
    Shao?Lin Xiong
    Chao Zheng
    Ke Gong
    Sheng Yang
    Xiao?Jing Liu
    Min Gao
    Xiang?Yang Wen
    Ya?Qing liu
    Yan?Bing Xu
    Xiao?Yun Zhao
    Jia?Cong Liu
    Fan Zhang
    Hong Lu
    Nuclear Science and Techniques, 2024, 35 (02) : 59 - 71