3D strain imaging using a rectilinear 2D array

被引:8
|
作者
Awad, Samer I. [1 ]
Yen, Jesse T. [1 ]
机构
[1] Univ So Calif, Viterbi Sch Engn, Los Angeles, CA 90089 USA
关键词
2-D array; 3-D imaging; strain imaging; ultrasound;
D O I
10.1177/016173460702900403
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Under mechanical compression, tissue movements are inherently three-dimensional. 2-D, strain imaging can suffer from decorrelation noise caused by out-of-plane tissue movement in elevation. With 3-D strain imaging, all tissue movements can be estimated and compensated, hence minimizing out-of-plane decorrelation noise. Promising 3-D strain imaging results have been shown using 1-D arrays with mechanical translation in elevation. However, the relatively large slice thickness and mechanical translation can degrade image quality. Using 2-D arrays, an improved elevational resolution can be achieved with electronic focusing. Furthermore, scanning with 2-D arrays is also done electronically, which eliminates the need for mechanical translation. In this paper, we demonstrate the feasibility of 3-D strain imaging using a 4 cm x 4 cm ultrasonic sparse rectilinear 2-D array operating at 5MHz. The signal processing combinations of 2-D or 3-D beamforming followed by 2-D or 3-D strain imaging are studied and compared to each other to evaluate the performance of our 3-D strain imaging system. 3-D beamforming followed by 3-D strain imaging showed best performance in all experiments.
引用
收藏
页码:220 / 230
页数:11
相关论文
共 50 条
  • [31] Fetal dacryocystocele: comparing 2D and 3D imaging
    Boris M. Petrikovsky
    Gary P. Kaplan
    [J]. Pediatric Radiology, 2003, 33 : 582 - 583
  • [32] 2D and 3D Convolutional and Correlation SAR Imaging
    Pepin, Matthew
    [J]. ALGORITHMS FOR SYNTHETIC APERTURE RADAR IMAGERY XXVII, 2020, 11393
  • [33] COMPRESSED 3D ULTRASOUND IMAGING WITH 2D ARRAYS
    Birk, Michael
    Burshtein, Amir
    Chernyakova, Tanya
    Eilam, Alon
    Choe, Jung Woo
    Nikoozadeh, Amin
    Khuri-Yakub, Pierre
    Eldar, Yonina C.
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2014,
  • [34] Guidance of the MitraClip® procedure by 2D and 3D imaging
    Labrousse, Louis
    Dijos, Marina
    Leroux, Lionel
    Oses, Pierre
    Seguy, Benjamin
    Markof, Muriel
    Lafitte, Stephane
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2018, 111 (6-7) : 432 - 440
  • [35] Recent results using a 256 x 256 2-D array transducer for 3-D Rectilinear Imaging
    Seo, Chi Hyung
    Yen, Jesse T.
    [J]. 2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1146 - 1149
  • [36] 2D or 3D?
    Mills, R
    [J]. COMPUTER-AIDED ENGINEERING, 1996, 15 (08): : 4 - 4
  • [37] 2D and 3D imaging of fatigue failure mechanisms of 3D woven composites
    Yu, B.
    Bradley, R. S.
    Soutis, C.
    Hogg, P. J.
    Withers, P. J.
    [J]. COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2015, 77 : 37 - 49
  • [38] Synthetic Transmit Aperture 3D Image Reconstruction Using 2D Transmitter Array
    Laokulrat, Natsuda
    Maeda, Yasushige
    Sugimoto, Masanori
    Hashizume, Hiromichi
    [J]. 2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 975 - 978
  • [39] Effectiveness of 3D geoelectrical resistivity imaging using parallel 2D profiles
    Aizebeokhai, A. P.
    Olayinka, A. I.
    Singh, V. S.
    Uhuegbu, C. C.
    [J]. CURRENT SCIENCE, 2011, 101 (08): : 1036 - 1052
  • [40] A 2D and 3D electrical impedance tomography imaging using experimental data
    [J]. Dmitry, S. (shulgadim@gmail.com), 2012, IEEE Computer Society