COMPRESSED 3D ULTRASOUND IMAGING WITH 2D ARRAYS

被引:0
|
作者
Birk, Michael [1 ]
Burshtein, Amir [1 ]
Chernyakova, Tanya [1 ]
Eilam, Alon [1 ]
Choe, Jung Woo
Nikoozadeh, Amin
Khuri-Yakub, Pierre
Eldar, Yonina C. [1 ]
机构
[1] Technion Israel Inst Technol, Dept Elect Engn, IL-32000 Haifa, Israel
关键词
Array Processing; Beamforming; Compressed Sensing; Speckle; Ultrasound;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Contemporary sonography is performed by digitally beamforming signals sampled by several transducer elements placed upon an array. High-resolution digital beamforming introduces the demand for a sampling rate significantly higher than the signal's Nyquist rate, which greatly increases the volume of data that must be processed. In 3D ultrasound imaging, 2D transducer arrays rather than 1D arrays are used, and more scan-lines are needed for volumetric imaging. This implies that the amount of sampled data is vastly increased with respect to 2D imaging. In this work we show that a considerable reduction both in sampling rate and processing time can be achieved by applying the ideas of Xampling and frequency domain beamforming, leading to a sub-Nyquist sampling rate. We extend previous work on frequency domain beamforming for 2D ultrasound imaging to the geometry imposed by 3D tissues and a grid of transducer elements. This method uses only a portion of the bandwidth of the ultrasound signals to reconstruct the image. We demonstrate our results by imaging a phantom comprised of fishing wires, and show that by performing 3D beamforming in the frequency domain, a sub-Nyquist sampling rate and a low processing rate are obtained, while keeping adequate image quality.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] A deep kiss with 2D and dynamic 3D ultrasound imaging
    Newton, N
    [J]. CLINICAL RADIOLOGY, 2000, 55 (12) : 987 - 987
  • [2] 3D from Compressed 2D Video
    Ideses, Ianir. A.
    Yaroslavsky, Leonid. P.
    Fishbain, Barak
    Vistuch, Roni
    [J]. STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS XIV, 2007, 6490
  • [3] Reconfigurable 2D cMUT-ASIC Arrays for 3D Ultrasound Image
    Song, Jongkeun
    Jung, Sungjin
    Kim, Youngil
    Cho, Kyungil
    Kim, Baehyung
    Lee, Seungheun
    Na, Junseok
    Yang, Ikseok
    Kwon, Oh-kyong
    Kim, Dongwook
    [J]. MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320
  • [4] 3D ultrasound coherence imaging based on 2D array design
    Jia, Yanping
    Xu, Mengling
    Ding, Mingyue
    Yuchi, Ming
    [J]. MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [5] 3D Passive Imaging of Ultrasound Cavitation using a 2D Array
    Boulos, Paul
    Varray, Francois
    Gilles, Bruno
    Bera, Jean-Christophe
    Cachard, Christian
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [6] Comparing 2D and 3D Imaging
    Ballantyne, Lauren
    [J]. JOURNAL OF VISUAL COMMUNICATION IN MEDICINE, 2011, 34 (03) : 138 - 141
  • [7] Variable-size elements in 2D sparse arrays for 3D medical ultrasound
    Diarra, Bakary
    Robini, Marc
    Liebgott, Herve
    Cachard, Christian
    Diarra, Bakary
    Tortoli, Piero
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 508 - 511
  • [8] Paravaginal defects: a comparison of clinical examination and 2D/3D ultrasound imaging
    Dietz, HP
    Pang, S
    Korda, A
    Benness, C
    [J]. AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2005, 45 (03): : 187 - 190
  • [9] Applications of 2D and 3D Ultrasound Imaging in Speech-Language Pathology
    Bressmann, Tim
    Heng, Chiang-Le
    Irish, Jonathan C.
    [J]. CANADIAN JOURNAL OF SPEECH-LANGUAGE PATHOLOGY AND AUDIOLOGY, 2005, 29 (04): : 158 - 168
  • [10] 2D airborne ultrasound piezotransducer arrays for corneal imaging
    Aminot, Antoine
    Shirkovskiy, Pavel
    Dorme, Christian
    Legros, Mathieu
    Dufait, Remi
    Fink, Mathias
    Ing, Ros Kiri
    [J]. 2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 800 - 802