Testing the limitations of 2-D companding for strain imaging using phantoms

被引:83
|
作者
Chaturvedi, P [1 ]
Insana, MF [1 ]
Hall, TJ [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Radiol, Kansas City, KS 66160 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.710585
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Companding may be used as a technique for generating low-noise strain images. It involves warping radio-frequency echo fields in two dimensions and at several spatial scales to minimize decorrelation errors in correlation-based displacement estimates. For the appropriate experimental conditions, companding increases the sensitivity and dynamic range of strain images without degrading contrast or spatial resolution significantly. In this paper, we examine the conditions that limit the effectiveness of 2-D local companding through a series of experiments using phantoms with tissue-like acoustic and elasticity properties. We found that strain noise remained relatively unchanged as the applied compression increased to 5% of the phantom height, while target contrast increased in proportion to the compression. Controlling the image noise at high compressions improves target visibility over the broad range induced in elastically heterogeneous media, such as biological tissues. Compressions greater than 5% introduce large strains and complex motions that reduce the effectiveness of companding. Control of boundary conditions and ultrasonic data sampling rates is critical for a successful implementation of our algorithms.
引用
收藏
页码:1022 / 1031
页数:10
相关论文
共 50 条
  • [1] 2-D companding for noise reduction in strain imaging
    Chaturvedi, P
    Insana, MF
    Hall, TJ
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) : 179 - 191
  • [2] 3-D companding using linear arrays for improved strain imaging
    Insana, MF
    Chaturvedi, P
    Hall, TJ
    Bilgen, M
    [J]. 1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1435 - 1438
  • [3] Strain Imaging Using a Rectilinear 2-D Array: Preliminary Results
    Awad, Samer I.
    Lye, Yan Lin
    Yen, Jesse T.
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 1270 - 1273
  • [4] Fast 2-D Ultrasound Strain Imaging: The Benefits of Using a GPU
    Idzenga, Tim
    Gaburov, Evghenii
    Vermin, Willem
    Menssen, Jan
    de Korte, Chris L.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (01) : 207 - 213
  • [5] Enhancing the Performance of Lateral Shear Strain Estimation by Using 2-D Strain Imaging
    Idzenga, Tim
    Hansen, Hendrik H. G.
    Thijssen, Johan M.
    de Korte, Chris L.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (05) : 756 - 764
  • [6] EVALUATING ATHEROSCLEROSIS OF THE ABDOMINAL AORTA IN RABBITS USING 2-D STRAIN IMAGING
    Dong, Zhihi
    Zhao, Yun
    Chen, Yue
    Liu, Zulin
    Song, Haiying
    Li, Hao
    Shi, Douzi
    Zhou, Chang
    Zhou, Jun
    Liu, Rong
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (11): : 2199 - 2206
  • [7] ANALYSIS OF 2-D ULTRASOUND CARDIAC STRAIN IMAGING USING JOINT PROBABILITY DENSITY FUNCTIONS
    Ma, Chi
    Varghese, Tomy
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (06): : 1118 - 1132
  • [8] Using 2-D Resistivity Imaging in Environmental Problems
    Jusoh, Zuriati
    Nawawi, M. N. M.
    Saad, Rosli
    Muztaza, Nordiana
    [J]. PROCEEDINGS OF 2010 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND DEVELOPMENT, 2010, : 265 - 268
  • [9] Seulimeum fault verification using 2-D resistivity imaging
    Kamaruddin, Nur Aminuda
    Syukri, Muhammad
    Saad, Rosli
    Nordiana, M.M.
    Marwan
    [J]. Electronic Journal of Geotechnical Engineering, 2014, 19 A : 91 - 100
  • [10] Volumetric ultrasound Imaging using 2-D CMUT arrays
    Oralkan, Ö
    Ergun, AS
    Cheng, CH
    Johnson, JA
    Karaman, M
    Lee, TH
    Khuri-Yakub, BT
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (11) : 1581 - 1594