Testing the limitations of 2-D companding for strain imaging using phantoms

被引:83
|
作者
Chaturvedi, P [1 ]
Insana, MF [1 ]
Hall, TJ [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Radiol, Kansas City, KS 66160 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.710585
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Companding may be used as a technique for generating low-noise strain images. It involves warping radio-frequency echo fields in two dimensions and at several spatial scales to minimize decorrelation errors in correlation-based displacement estimates. For the appropriate experimental conditions, companding increases the sensitivity and dynamic range of strain images without degrading contrast or spatial resolution significantly. In this paper, we examine the conditions that limit the effectiveness of 2-D local companding through a series of experiments using phantoms with tissue-like acoustic and elasticity properties. We found that strain noise remained relatively unchanged as the applied compression increased to 5% of the phantom height, while target contrast increased in proportion to the compression. Controlling the image noise at high compressions improves target visibility over the broad range induced in elastically heterogeneous media, such as biological tissues. Compressions greater than 5% introduce large strains and complex motions that reduce the effectiveness of companding. Control of boundary conditions and ultrasonic data sampling rates is critical for a successful implementation of our algorithms.
引用
下载
收藏
页码:1022 / 1031
页数:10
相关论文
共 50 条
  • [21] Improvement of a system for 2-D optoacoustic imaging using a deconvolution filter
    Gonzalez, M. G.
    Massaro Rocca, P.
    Ciocci Brazzano, L.
    Acosta, E.
    Santiago, G.
    2018 IEEE BIENNIAL CONGRESS OF ARGENTINA (ARGENCON), 2018,
  • [22] Assessment of Quarry Volume Using 2-D Resistivity Imaging Method
    Saad, Rosli
    Mohamad, Edy Tonnizam
    Nordiana, M. M.
    Azwin, I. N.
    Tan, Norsalkini Mohd. Akip
    2012 NATIONAL PHYSICS CONFERENCE (PERFIK 2012), 2013, 1528 : 169 - 174
  • [23] Damage detection using 2-D strain energy distribution and scanning laser
    Chen, SE
    Venkatappa, S
    Petro, S
    GangaRao, H
    IMAC - PROCEEDINGS OF THE 17TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS I AND II, 1999, 3727 : 869 - 875
  • [24] Wireless Remote 2-D Strain Sensor Using SAW Delay Line
    Nomura, T.
    Saitoh, A.
    MATERIALS AND DEVICES FOR SMART SYSTEMS III, 2009, 1129 : 33 - +
  • [25] Development and testing of a 2-D transfer CCD
    Smith, David R.
    Holland, Andrew D.
    Martin, Adrian
    Burt, David
    Eaton, Tim
    Steward, Roy
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2006, 53 (11) : 2748 - 2754
  • [26] Longitudinal, Radial and Circumferential 2-D Cardiac Strain Imaging in Healthy Subjects Following a Marathon
    Shave, Robert
    George, Keith
    Oxborough, David
    Whyte, Greg
    Middleton, Natalie
    Hart, Emma
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S321 - S321
  • [27] Testing 3D-SoCs Using 2-D Time-Division Multiplexing
    Georgiou, Panagiotis
    Vartziotis, Fotis
    Kavousianos, Xrysovalantis
    Chakrabarty, Krishnendu
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2018, 37 (12) : 3177 - 3185
  • [28] Does a 3-D strain analysis invalidate 2-D strain? Observations in hypertensive left ventricular hypertrophy from the LIFE trial using magnetic resonance Imaging
    Biederman, RW
    Doyle, M
    Young, AA
    Oparil, S
    Pohost, GM
    Dell'Italia, LJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 229A - 229A
  • [29] A 2-D acoustic array for diagnostic imaging
    Bechtold, M
    Granz, B
    Oppelt, R
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 1573 - 1576
  • [30] 2-D CVIB imaging in animal experiments
    Jiang, Y
    Bai, J
    Cheng, KZ
    Yu, C
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1419 - 1422