Verification of the ProPneumo-1 assay for the simultaneous detection of Mycoplasma pneumoniae and Chlamydophila pneumoniae in clinical respiratory specimens

被引:3
|
作者
Higgins, Rachel R. [1 ]
Lombos, Ernesto [1 ]
Tang, Patrick [1 ]
Rohoman, Karl [1 ]
Maki, Anne [1 ]
Brown, Shirley [1 ]
Jamieson, Frances [1 ,2 ]
Drews, Steven J. [1 ,2 ,3 ]
机构
[1] Ontario Publ Hlth Labs, Minist Hlth & Long Term Care, Toronto, ON, Canada
[2] Univ Toronto, Dept Pathol & Lab Med, Toronto, ON, Canada
[3] Mt Sinai Hosp, Toronto, ON, Canada
关键词
Mycoplasma Pneumoniae; Diagnostic Specificity; Clinical Microbiology Laboratory; Chlamydophila Pneumoniae; Respiratory Tract Specimen;
D O I
10.1186/1476-0711-8-10
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Mycoplasma pneumoniae and Chlamydophila pneumoniae are major causes of lower and upper respiratory infections that are difficult to diagnose using conventional methods such as culture. The ProPneumo-1 (Prodesse, Waukesha, WI) assay is a commercial multiplex real-time PCR assay for the simultaneous detection of M. pneumoniae and/or C. pneumoniae DNA in clinical respiratory samples. Objective: The aim of this study was to evaluate the sensitivity and specificity of the ProPneumo1, a newly developed commercial multiplex real-time PCR assay. Methods: A total of 146 clinical respiratory specimens, collected from 1997 to 2007, suspected of C. pneumoniae or M. pneumoniae infections were tested retrospectively. Nucleic acid was extracted using an automated NucliSense easyMag (bioMerieux, Netherlands). We used a "Homebrew" monoplex real-time assay as the reference method for the analysis of C. pneumoniae and culture as the reference method for the analysis of M. pneumoniae. For discordant analysis specimens were re-tested using another commercial multiplex PCR, the PneumoBacter-1 assay (Seegene, Korea). Results: Following discordant analysis, the sensitivity of the ProPneumo-1 assay for pathogens, C. pneumoniae or M. pneumoniae, was 100%. The specificity of the ProPneumo-1 assay, however, was 100% for C. pneumoniae and 98% for M. pneumoniae. The limits of detection were 1 genome equivalent (Geq) per reaction for pathogens, M. pneumoniae and C. pneumoniae. Due to the multipex format of the ProPneumo-1 assay, we identified 5 additional positive specimens, 2 C. pneumoniae in the M. pneumoniae-negative pool and 3 M. pneumoniae in the C. pneumoniae-negative pool. Conclusion: The ProPneumo-1 assay is a rapid, sensitive and effective method for the simultaneous detection of M. pneumoniae and C. pneumoniae directly in respiratory specimens.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Evaluation of a New Real-time PCR Assay for Detection of Mycoplasma Pneumoniae in Clinical Specimens
    Zhao Fei
    Cao Bin
    He Li Hua
    Yin Yu Dong
    Tao Xiao Xia
    Song Shu Fan
    Meng Fan Liang
    Zhang Jian Zhong
    BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2012, 25 (01) : 77 - 81
  • [23] Pneumonia caused by Mycoplasma pneumoniae and Chlamydophila pneumoniae in children - comparative analysis of clinical picture
    Kicinski, P.
    Wisniewska-Ligier, M.
    Wozniakowska-Gesicka, T.
    ADVANCES IN MEDICAL SCIENCES, 2011, 56 (01): : 56 - 63
  • [24] Detection of Chlamydophila pneumoniae (Chlamydia pneumoniae) in endarteroctomy specimens of coronary heart diseases patients
    Satpathy, Gita
    Bhan, Anil
    Sharma, Anjana
    Kar, U. K.
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2008, 128 (05) : 658 - 662
  • [25] Development of real-time multiplex nucleic acid sequence-based amplification for detection of Mycoplasma pneumoniae, Chlamydophila pneumoniae, and Legionella spp. in respiratory specimens
    Loens, K.
    Beck, T.
    Ursi, D.
    Overdijk, M.
    Sillekens, P.
    Goossens, H.
    Ieven, M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (01) : 185 - 191
  • [26] SINGLE TUBE REAL TIME PCR FOR DETECTION OF STREPTOCOCCUS PNEUMONIAE, MYCOPLASMA PNEUMONIAE, CHLAMYDOPHILA PNEUMONIAE AND LEGIONELLA PNEUMOPHILA FROM CLINICAL SAMPLES OF CAP
    Nomanpour, Bizhan
    Ghodousi, Arash
    Babaei, Toraj
    Jafari, Siroos
    Feizabadi, Mohammad Mehdi
    ACTA MICROBIOLOGICA ET IMMUNOLOGICA HUNGARICA, 2012, 59 (02) : 171 - 184
  • [27] Evaluation of the combination of the NucliSENS easyMAGA® and the EasyQA® applications for the detection of Mycoplasma pneumoniae and Chlamydia pneumoniae in respiratory tract specimens
    Bessede, E.
    Renaudin, H.
    Clerc, M.
    de Barbeyrac, B.
    Bebear, C.
    Pereyre, S.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2010, 29 (02) : 187 - 190
  • [28] Evaluation of the combination of the NucliSENS easyMAG® and the EasyQ® applications for the detection of Mycoplasma pneumoniae and Chlamydia pneumoniae in respiratory tract specimens
    E. Béssède
    H. Renaudin
    M. Clerc
    B. de Barbeyrac
    C. Bébéar
    S. Pereyre
    European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 187 - 190
  • [29] DIRECT DETECTION OF MYCOPLASMA-PNEUMONIAE ANTIGEN IN CLINICAL SPECIMENS BY A MONOCLONAL-ANTIBODY IMMUNOBLOT ASSAY
    MADSEN, RD
    WEINER, LB
    MCMILLAN, JA
    SAEED, FA
    NORTH, JA
    COATES, SR
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1988, 89 (01) : 95 - 99
  • [30] Rapid Detection of Mycoplasma pneumoniae by Loop-Mediated Isothermal Amplification (LAMP) in Clinical Respiratory Specimens
    Arfaatabar, Maryam
    Noori Goodarzi, Narjes
    Afshar, Davoud
    Memariani, Hamed
    Azimi, Ghasem
    Masoorian, Ensieh
    Pourmand, Mohammad Reza
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2019, 48 (05) : 917 - 924